Showing results: 91 - 105 of 560 items found.
-
40-146-202 -
Pickering Interfaces Ltd.
The 40-145/46/48 range of high density switching modules are available in Normally Open (SPST & DPST) and changeover (SPDT) configurations. Connections are made via a front panel 200 pin female connector. General purpose relays are suitable for the construction of small switching networks, I/O port switching, for slave switching larger relays or for operating external devices (e.g. lamps, solenoids etc.).
-
40-180-001 -
Pickering Interfaces Ltd.
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDCThe 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
40-137-001 -
Pickering Interfaces Ltd.
These PXI Power Relay Modules are suitable for applications requiring power relay switching with high density. This version features 5A current and voltage to 110VDC/250VAC, they are configured as Single Pole Single Throw (SPST). Connections are made via front panel mounted 37 or 78-pin D-Type connector. Along with this 16 x SPST, 5A version, the range also includes a 39 x SPST, 2A version and a 32x SPST version - go to Also in the Range above to learn more. Typical applications will be found in Automotive Test, Aerospace Test and Power Cell Test applications.
-
40-110-021 -
Pickering Interfaces Ltd.
The 40-110/115 range of switching modules are available in both Changeover (SPDT) and Normally Open (SPST & DPST) configurations. Connections are made via a front panel 96 pin male micro-D connector. General purpose reed relays are used for the construction of small switching networks or for slaving up to larger switches.To simplify inter-relay wiring, interconnection points are built onto the circuit board thus easing the construction of complicated wiring.
-
40-170-002 -
Pickering Interfaces Ltd.
Model 40-170 is available either as 2 x SPST High Power Relays, suitable for switching inductive/ capacitive loads up to 30A at 250VAC or as 2 x DPST switching up to 20A. Power Relay Modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
40-145-001 -
Pickering Interfaces Ltd.
The 40-145/46/48 range of high density switching modules are available in Normally Open (SPST & DPST) and changeover (SPDT) configurations. Connections are made via a front panel 200 pin female connector. General purpose relays are suitable for the construction of small switching networks, I/O port switching, for slave switching larger relays or for operating external devices (e.g. lamps, solenoids etc.).
-
40-180-011 -
Pickering Interfaces Ltd.
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
40-115-122 -
Pickering Interfaces Ltd.
Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.
-
40-146-002 -
Pickering Interfaces Ltd.
The 40-145/46/48 range of high density switching modules are available in Normally Open (SPST & DPST) and changeover (SPDT) configurations. Connections are made via a front panel 200 pin female connector. General purpose relays are suitable for the construction of small switching networks, I/O port switching, for slave switching larger relays or for operating external devices (e.g. lamps, solenoids etc.).
-
40-139-102 -
Pickering Interfaces Ltd.
The 40-139 2A Relay Series is suitable for applications requiring medium power switching with high density.Featuring 2A current capacity and voltages to 300VDC/250VAC it is useful for cost critical applications.
-
40-180-101 -
Pickering Interfaces Ltd.
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC. The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
40-161-102 -
Pickering Interfaces Ltd.
This40-161 range of PXI power relay modules is available with achoice of 16 x SPST, 12 x SPST, 10 x SPST, 12 x SPDT and 6 x SPDT power relays, for switching loads up to 16A at250VAC. These Power Relay Modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. The 40-161 is ideal for switching up to 16A in both AC and DC applications.
-
40-130-002 -
Pickering Interfaces Ltd.
Pickering Interfaces 40-130 DPDT Relay Modules are suitable for applications where ordinary reed relay modules require additional current/voltage capacity. It is available in a choice of 8 and 13 relay versions and has voltage handling up to 220VDC/125VAC and current handling to 2A . Connections are made via a front panel mounted 50 or 78 pin D-Type connector.
-
40-141-022 -
Pickering Interfaces Ltd.
The 40-140A/141/143 range of high density switching modules are available in Normally Open (SPST & DPST) and changeover (SPDT) configurations. Connections are made via a front panel 200 pin female connector.
-
40-136-212 -
Pickering Interfaces Ltd.
The 40-136-212 19xDPST reed relay module is part of our range of medium power, general purpose relay modules which are capable of switching voltages up to 200V and current up to 2A.