Showing results: 2296 - 2310 of 2826 items found.
-
PGY-UHS II SD/SDIO -
Prodigy Technovations Pvt. Ltd.
UHS II Protocol Analyzer (PGY-UHS II SD/SDIO) is the Protocol Analyzer with multiple features to capture and debug communication between host and design under test. PGY-UHS II SD/SDIO UHS II Protocol Analyzer is the most feature rich comprehensive Protocol Analyzer available to capture and debug UHS-II protocol data. PGY-UHS-II Protocol Analyzer supports FD156 and HD312 data rate. The innovative active probe has minimum electrical loading on device under test (DUT) and captures protocol data without affecting the performance of DUT.
-
MSOV084A -
Keysight Technologies
8 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOV204A -
Keysight Technologies
20 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.54 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOV254A -
Keysight Technologies
25 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOV164A -
Keysight Technologies
16 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOV134A -
Keysight Technologies
13 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Modus Test, LLC
Instrumentation• 16,128 Kelvin ChannelsApplications• Cres Test Characterization For Test Sockets / Probe Heads / Connectors• Package Testing / Qualification• Device Opens / Shorts Testing• MTC Compatible For Integrated Cycling / Stepping / Force Measurement• MTC-TC Compatible For Hot/cold Thermal Chamber Characterization
-
Qinhuangdao Boostsolar Photovoltaic Equipment Co., Ltd
-Double power transmission is controlled separately, the transmission is stable, and the synchronous transmission is realized.-Docking with the assembly line, automatic transmission and positioning, automatic testing of components through probes, and complete automatic testing of components.-It can be used with international famous brand testers such as HAIM and SPIRE.
-
3700 -
Peaceful Thriving Enterprise Co Ltd
*2 x 6m retractable test leads.*Used as an extension cord for cars, trailers, boats and more.*Optional accessory included alligator clips, test probes and banana plugs.*The tester can be used with any multi meter or device equipped with banana jack connectors.
-
CITS900s4 -
Polar Instruments Inc
CITS900s4 is the seventh generation of Impedance test system from polar, and typically the most popular model for customers who are new to impedance control. CITS900s4 provides both differential and single ended measurement capability along with 4 channels to provide flexible probe connection.
-
CMM Camera System -
Aberlink Ltd
Aberlink’s camera system offers a non-contact facility on any Aberlink CMM. A innovative design of magnetic, kinematic joint allows the probe and camera to be swapped in just seconds. This means that components can be inspected using both touch trigger and vision inspection technology on the same machine.
-
Ferrites India
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
Extech MO290 -
Extech Instruments Corporation
The MO290 is an 8-in-1 meter that combines a Pin/Pinless Moisture Meter with a built-in InfraRed Thermometer. Additional measurements include: Temperature, Humidity, Grains per Pound, Dew Point, Vapor Pressure, and Condensation Point. Complete with pin moisture probe, 9-Volt battery, and case.
-
EOTPR 3000 -
TeraView Ltd
The EOTPR 3000 system is configured with a manual probe station to meet today’s tough FA environment which requires to isolate fault location in minutes rather than hours or days, while maintaining the EOTPR’s world leading sub-5 μm fault isolation accuracy.
-
Model SST500X500 -
Gopal Electronics
Gopal Make single sheet tester SST is developed as per IEC 60404-3. It can be attached as probe to Ep400 Main unit and user can test specific total loss, specific apparent power, and r.m.s value of magnetic field strength as well as B/h curve in the software.