Showing results: 766 - 780 of 2826 items found.
-
Non-Contact & Socket -
Amprobe Test Tools
Use Amprobe non-contact volt probes to safely check circuit breakers, wall sockets and fuses for voltage presence with portable, economical tools. For sockets, choose an Amprobe socket tester, which can confirm whether GFCI breakers are properly wired.
-
Cryogenic Ltd.
To perform measurements at or above room temperature, separate heated sample probes are offered for electrical or magnetic measurements. In normal operation, the CFMS has a continuous temperature range of 1.6 K to 400 K. With these inserts the range can be extended up to 1000 K.
-
Projekt Elektronik Mess- und Regelungstechnik GmbH
The active probes are equipped with active amplifier electronics and have an extremely low-impedance output, ie they can also drive long lines. The output signal is calibrated according to specification. They can not only be connected to a certain type of teslameter, but can also be connected to any signal input.
-
SONOSCAN P -
SONOTEC GmbH
The ergonomic straight beam probes of the SONOSCAN Series for Nondestructive Testing (NDT) comply with the European Standard DIN EN 12668-2. Our ultrasonic transducers are used to check metals, plastics and ceramic materials for discontinuities, such as cracks, inclusions, blowholes and other material flaws.
-
HMP7 -
Vaisala Oyj
Vaisala HUMICAP® Humidity and Temperature Probe HMP7 is designed for applications which involve constant high humidity or rapid changes in humidity such as drying and test chambers, combustion air and other humidifiers and meteorological measurements where measurement performance and chemical tolerance are essential.
-
8716 -
TEGAM Inc.
For measuring atmospheres in hoods, ducts, and vents. A perforated-style shield protects the thermocouple tip from radiated temperature change in order to provide more accurate readings. The 8-1/2" sheath is constructed of 304 stainless steel. The probe is supplied with a 3-ft straight cord.
-
LPUVA03…Series -
Delta OHM S.r.L.
The LPUVA03 probe measures irradiance (W/m²) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m²) in the UVA (315 nm…400 nm) spectral range. Thanks to a new type of photodiode, LPUVA03 is blind to visible and infrared light.
-
Teledyne LeCroy
The PPE6KV-A and HVP120 can handle up to 6000 Vpeak transient overvoltages and are designed for probing up to 2000 Vrms and 1000 Vrms respectively. Fast rise times, excellent frequency response, and a variety of standard accessories make these probes safe and ideal for high voltage measurement applications
-
MPI Advanced Semiconductor Test
MPI designed dedicated SiPH upgrades for its well known 200 and 300 mm probe systems, which includes:*Various options of high-precision fiber alignment systems for ultra-fast scanning routines*Multiple measurement capabilities for O-O, O-E, E-O and E-E device configuration*Integrated Z-sensing for detecting the fiber to wafer contact point*Crash protection when using two optical fiber arms*Wide temperature range from -50°C to 200°C*Optional dark box for testing in light tight environment*Extensive software package for supporting easy integration to operator’s test executive*Probe system compatibility: TS2000-IFE, TS2000-SE, TS3000, TS3000-SE, TS3500 and TS3500-SE
-
Teledyne LeCroy
High voltage differential probes provide high CMRR over a broad frequency range (up to 400 MHz) to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
-
34A -
Picoprobe
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.
-
LPUVB03BLAV -
Delta OHM S.r.L.
The LPUVB03BLAV probe measures global irradiance (W/m²) on a surface area (m²) in the UVB (280 nm…315 nm) spectral region. In particular, the spectral sensitivity is focused at 305 nm, with a bandwidth (FWHM) of 5 nm. The global irradiance is the result of the sum of direct solar irradiance and of diffused irradiance incident on a planar surface.
-
84-08-15 -
Testing Machines, Inc.
The Probe Tack Adhesion Fixture is a tool used for the measurement of the pressure sensitive tack of adhesives. Tack is typically measured as the force required to separate an adhesive and the adherend shortly after having been brought into contact under a defined load of known duration at a specified temperature. Tack is measured as the maximum force required to break the adhesive bond.
-
DP750-100 -
Shenzhen Micsig Instruments Co., Ltd.
*The leads and probe are with shielded design, interface ends are integrated in a compact box, no need to twist the cables, leads to a lower noise floor and has less interference. *Support one-press Zero calibration and automatic overrange alarm.*Directly powered by Micsig UPI interface, realise auto scaling setup, can also powered by oscilloscope via USB cable.
-
MPI Advanced Semiconductor Test
MPI’s 200 mm and 300 mm automated probe systems are dedicated and designed to address current and future requirements for all facets of Device Characterization for Modeling and Technology/Process Development, Failure Analysis, Design Verification, IC engineering, Wafer Level Reliability as well as special requirements for MEMS, High Power, RF and mmW device testing.