Showing results: 1156 - 1170 of 2826 items found.
-
I-prober 520 -
Aim-TTi
Current measurement from insulated probing of conductorSuitable for observation and measurement of current in PCB tracks, component leads and ground planesWide dynamic range of 10mA to 20A peak to peakWide bandwidth of DC to 5MHzLow noise figure equivalent to <6mA rms at full B/WSafety rated to 300V Cat II (600V Cat 1)Suitable for connection to any oscilloscopeHigh accuracy general purpose H-field probeConverts to 'closed magnetic circuit' current probe
-
MetrologyWorks, Inc.
Single Piece Aluminum InsertWe have assembled this SMR in a way that the insert will not come out. When you drop the competitions SMR they shift or pop out after a few short drops. With our Rhino Series SMR, Drop, Pickup, and Measure on. You get the performance of a solid SMR that is much more affordable. These are available in High Accuracy SMR versions. We keep the Rhino Series SMR s in stock at all times.
-
CyberScan pH 11 -
Thermo Scientific
5-point Push-Button Calibration with Auto-Buffer Recognition for quick calibration with no calibration mistakes
-
FLIR TA74 -
Teledyne FLIR
The FLIR TA74 adds capabilities, simplifies challenges, and gives you the best readings with your existing meter. The narrow, 18-inch long flexible coil clamp and locking mechanism allows you take measurements in tight or awkward spots – ideal for multiple conductor measurements, double-wrap requirements, and deeper access. The connection is a standard banana plug and the output is a voltage signal, so it’s compatible with most DMMs and clamp meters, regardless of brand.
-
1668A -
Peaceful Thriving Enterprise Co Ltd
Check on 6 and 12V systems. To indicate whether there is an electrical potential at any low voltage point in the system. By using the pointed contact tip to pierce insulation on cables, it will also indicate if current is present. This can be helpful when tracing faults or add cable to a circuit.
-
D400A-AT-PB2 -
Teledyne LeCroy
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
D600A-AT-PB2 -
Teledyne LeCroy
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
D600A-AT-PL -
Teledyne LeCroy
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
-
-
90061-XH Series -
HITEC Sensor Solutions Inc.
This system is ideal for field measurement and data logging of forces between the tips of resistance spot welders. The system consists of a handheld sensor and portable readout/ data logger (PMAC 2000).
-
RT70V series -
NAPSON Corp.
• Combinational measurement system by Measurement tester(RT-70V) & Stage.• Thickness input with easy JOG dial operation (RT-70V Tester)• Tester self-test function/Auto change-over measurement range function• Thickness & Temperature correction function for Silicon sample
-
1169B -
Keysight Technologies
Provides a large common mode range and a large offset range for measuring differential and single-ended signals.
-
1168B -
Keysight Technologies
Provides a large common mode range and a large offset range for measuring differential and single-ended signals.
-
PP016 -
Teledyne LeCroy
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.