Showing results: 1276 - 1290 of 2826 items found.
-
ZS4000 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.6 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.
-
ZS2500 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.
-
PRB-HP-9060 -
TEAM SOLUTIONS, INC.
*Up to 60MHz*Includes a handy storage pouch and includes an IC test-hook adapter for the probe.*The BNC connector rotates to avoid cable tangle or kink.*Cable length is 1.4 meters.
-
ZD200 -
Teledyne LeCroy
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
TCR-600 -
NAPSON Corp.
*Controlled Thermo-chuck (room temperature~600℃/less than 20 minutes)*600C compatible probe head with 1mm linear*Controlled with vacuum sensor, digital thermo-meter, vacuum gauge and gas flow meter*Temperature measuring accuracy:±(0.5% + 1℃)
-
Extech TP873 -
Extech Instruments Corporation
The Extech TP873 is a Bead Wire Type K Temperature Probe that can measure temperature from -30°C to 300°C (-22°F to 572°F). It is compatible with most test instruments that have a Type K Temperature input. Complete with a Type K mini connector and banana plug adaptor.
-
PC 700 -
Thermo Scientific
The multi-parameter Eutech PC 700 measures pH, ORP, conductivity and temperature with a single meter. User-friendly with advanced features and a large custom-size display – perfect for research work on a budget!
-
PACC-ZD009 -
Teledyne LeCroy
Micro pogo pin tips for ZD differential probeQty 6
-
T3PP350 -
Teledyne LeCroy
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
PP006D -
Teledyne LeCroy
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
PP007-WS-1 -
Teledyne LeCroy
The PP007 embodies leading technology in passive probe design. The small probe is optimized for maximum waveform fidelity, including high frequency signal components, in a rugged probe suitable for every day.The sharp probe tip* is spring loaded, allowing it to retract into the narrow probe head. The tip does not slip off the object being probed—important when probing small geometry surface-mounted components. Probing dense circuits is easier with the small 2.5 mm ground sleeve, which provides much better visibility than 5 mm and 3.5 mm probes.
-
EC-80P (Portable) -
NAPSON Corp.
*Auto-measurement start by probe head contacting to sample*3 measurement modes for wafer resistivity, bulk resistivity and sheet resistance*Easy set up to measurement condition by JOG dial*5 types of model for each measuring range*Resistivity probe can be changed by sample’s resistivity range
-
72-3040 -
Tenma
A high voltage probe that allows most 10MΩ multimeters to be turned into a high voltage meter.
-
HVD3106A -
Teledyne LeCroy
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
HVD3206A -
Teledyne LeCroy
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.