Filter Results By:

Products

Applications

Manufacturers

RS232

A standard interface for serial binary data interchange defining voltage levels for logical one and logical zero, standard transmission speed and connector types.

See Also: Serial Communications, I2C, RS422, RS485


Showing results: 601 - 615 of 934 items found.

  • Ethernet Parallel Interface

    Model 8113 - ICS Electronics

    * Provides 12 8CMOSL I/O lines for 3.3 and 5 volt logic.* 10/100 MHz Ethernet Interface with Auto-MDIX capability* Robust hardwired TCP/IP (Raw Socket) communication port prevents flooding, spoofing and injection attacks.* Included RS-232 serial control port for older systems.* Optional I2C port for connection to touchscreen panel or other I2C devices.* Standard board has a horizontal Ethernet connector and 150-pin Digital IO connector on the component side.

  • Large Photo Signal Generator

    DDS9m - Novatech Instruments , Inc.

    170MHz 4-Channel Signal Generator. The DDS9m generates four independent, phase synchronous sine wave output signals and is programmable in 0.1Hz steps from 0.1Hz to 171MHz. Programming is via an RS232 serial interface. Phase is 14-bit programmable and amplitude is 10-bit programmable. The DDS9m is accurate to 1.5ppm when using the on board TCXO timebase or you can use an external timebase. It requires 3.3 VDC power. SOF8_409 windows software is available as an extra cost accessory.

  • Dual Display Auto-Ranging LCR Meter

    LCR 459 - Kusam Electrical Industries Limited

    • Dual Displays provide quick tested results readouts, with L.C.R. display values up to 19999 counts and Q.D.R. display values up to 9999 counts • Test 4 parameters : Ls+(Q,D,Rs), Lp+(Q,D,Rp), • Cs+(Q,D,Rs), Cp+(Q,D,Rp) • RS-232 PC Interface • External DC Adapter functions • Set Hi / Lo limits using absolute values or percentage limits.

  • Power Bus

    MS 1606 - Meltronics Systemtech

    The PowerBus is used to service printed circuit boards, instruments and systems, which has Micro controller / Microprocessor. The PowerBus has RS232 Communication for PC interface. The PowerBus connects to the UUT through the microprocessor / micro controller socket. The UUTs microprocessor / micro controller is removed from the UUT and it is replaced by the PowerBus. The Power Bus adapts microprocessor specific function as pin layouts, status / control function, interrupt handling, timing and memory and I / O addressability.

  • High Performance High Power DC Electronic Load

    IT8900A/E Series - I-TECH Electronic Co., Ltd

    IT8900A/E series high performance high power DC electronic load provides three voltage ranges 150V/600V/1200V, stand-alone power from 2kW to 54kW. IT8900A/E series, with ultra-wide voltage and current range, controlled by an independent master unit. The power expands to 384kW by master-slave paralleling. Ultra-high power density, 6kW is with only 4U height. IT8900A/E series has eight (A series) / four (E series) working modes, faster loop response and current rising and falling speed, as well as dynamic mode, OCP test, OPP test, automatic test and battery test functions. Built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, etc., IT8900A/E series has full protection function, which can be applied to power battery discharge, DC charging station, on-board charger (OBC), power electronics and other power electronics products.

  • Bench/System Multi-Range DC Power Supply With Digital Control, 3 Or 4 Outputs, 315 To 420W With/without Remote Interfaces

    MX Series - Aim-TTi

    Three or four high performance outputs each with full functionalityRange switching gives variable voltage/current combinationsShared power mode provides double power from a single outputLow output noise and ripple via linear final regulationHigh setting resolution of up to 1mV and 0.1mAVariable OVP and OCP trips on all outputs50 setting memories per output plus 50 linked memoriesSelectable voltage tracking (isolated tracking)Selectable current meter averagingSwitchable remote sense capabilityGraphic LCD provides simultaneous output meteringNumeric or spin-wheel control of all parametersIndividual or combined output on/off control with programmable delay sequencing.3U half-rack case for bench or rack mounting (4U rack kit accessory available)RS-232, USB and LAN (LXI) interfaces (P models)GPIB option (P models only)Duplicate power & sense terminals at rear (P models)

  • Batteryless System Logger

    SKU-004-01 - Amfeltec Corp.

    The Batteryless System Logger is a unique device that was designed to log system data from any serial port, and store the data in the Logger’s non-volatile memory; this is done in the event of a system crash or power outage. The Logger is ideal for companies in the embedded appliance market.The System Logger connects to the embedded system via the serial RS-232 port. It continuously receives log info from the system, and stores this log info on an internal cycle buffer. This info can be retrieved via the serial interface at any time.

  • Component Test Scanner

    Model 13001 - Chroma ATE Inc.

    Support component test scanningSupport 8 slots for plug-in (removable), up to 320 channels for one unitOption A130007 40 channels scan module, input up to 500VDC for IR test without switchingMax. 8 salve units for multiple scanner (master/slave interface)Support Chroma LCR meterSupport Chroma 3302/3252/11025 turn ration functionSupport 11200 CLC/IR meter for IR testStandard RS-232, GPIB and USB interface13001 can be installed in Chroma Component ATE model 8800Support ICT applications

  • CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel

    40-200-004 - Pickering Interfaces Ltd.

    Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Universal Radiometer

    Rm-3700 - Laser Probe Inc.

    The Rm-3700 Single Channel Universal Radiometer, when used with the correct probe, can measure cw and average power (in Watts), as well as the energy (in Joules) of individual pulses up to 2 kHz, over a wide range of intensities and wavelengths. A high-speed Rs-232 computer interface, full statistical analysis of pulse sets, battery/AC power, and audible tuning are just some of the standard features. This tremendous versatility makes it the ideal instrument for research labs, universities, hospitals, and other facilities with multiple light sources and applications.

  • PDL Emulator

    PDLE-101 - General Photonics Corp.

    The PDLE-101 is specially designed for such PDL-related tests. This PDL source/ emulator can generate individual PDL values between 0 dB and 20 dB, with a resolution of 0.1 dB for PDL tolerance testing. It can also generate variable PDL with user defined range, waveform, and speed for PDL tracking speed and recovery time tests. The instrument can be controlled via the front panel keypad or by remote control via USB, RS-232, GPIB, or Ethernet interfaces. The residual PMD of the unit is less than 0.1 ps.

  • Transistor Curve Tracers

    Shanghai MCP Corp

    Store characteristic curves and panel setting parameters. Programmable test conditions ,measured results PC stored. Three cursor measurement modes: point, line, window. Two cluster characteristic curves display simultaneouslyfor compare and pairing. Screen read outβ, gm, Vce, Ic, breakdown voltage, leakage current and other parameters . Repeat and single measurement. Self-checking function . 7 Inch high-resolution TFT color LCD. Standard interface: USB, RS232, LAN

  • Mobile Apps for iOS and Android

    LoggerLink - Campbell Scientific, Inc.

    LoggerLink Mobile Apps are simple yet powerful tools that allow an iOS or Android device to communicate with our CR200X, CR800, CR850, CR1000, CR3000, or CR6 dataloggers via an IP device (NL115, NL116, NL120, NL121, NL201, NL240, RavenXTV, RavenXTG, LS300G). LoggerLink for Android also supports Bluetooth communication for these same dataloggers using an RS-232-Bluetooth adapter. The apps support field maintenance tasks such as viewing and collecting data, setting the clock, and downloading programs.

  • Battery Load Bank

    Foresight Electronics Co., Ltd.

    Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge

  • Capacitor Leakage Current Meter

    DU2316/2317 - Delta United Instrument Co., Ltd.

    Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed

Get Help