Filter Results By:

Products

Applications

Manufacturers

Showing results: 166 - 180 of 214 items found.

  • Phase Noise Testers / Signal Source Analyzers

    7000 Series - Berkeley Nucleonics Corporation

    The 7000 series is an all-in-one integrated solution that offers an indispensable set of low-noise phase measurement functions. Offering both Absolute and Additive(residual) measurement capabilities in one unit at no additional cost, the 7000 series is the most flexible solution on the market. The instrument comprises a two-channel, cross-correlation system with two internal, tunable references sources that also allows measurements with externally sourced references. We offer three platform options for the 7000 Series Phase Noise Testers: the 7070 1 MHz to 7 GHz, the 7300 1 MHz to 26 GHz, 7340 1 MHz to 40 GHz, 7350 1 MHz to 50 GHz, and the 7360 1 MHz to 65 GHz.

  • Low Power Potentiostats

    Bank Elektronik

    Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg

  • RF Calibration Accessories

    Fluke Calibration

    Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.

  • FPGA Mezzanine Card

    FMC165 - Abaco Systems Inc

    The FMC165 provides two 14-bit analog-to-digital (A/D) channels supporting RF sampling at 2.6 GSPS and one 14-bit digital-to-analog (D/A) channel with sampling rates up to 5.2 GSPS (2.6 GSPS direct RF synthesis). The converters are clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users.

  • Mid-Range Gas Filter Correlation CO Analyzer​

    Model T300M - Teledyne Advanced Pollution Instrumentation

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.

  • Reference Transmitter

    81492A - Keysight Technologies

    Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • 1231a Very High Frequency Distribution

    Precise Time and Frequency, Inc.

    The ptf 1230A(1U)/1231A(2U) GPS L-Band RF Distribution amplifiers provide high performance GPS signal references for laboratory or systems use. In most applications the low noise and signal gain capability of the units will provide userswith a robust GPS signal source for lab or system requirements.The ptf 1230A/1231A uses individually buffered output stages and insures maximum isolation between the individual outputs. The ptf 1231A offers 12 outputs. Options are available for a 2U/3.5” version (ptf 1230A) with 24 outputs.Isolation from output to output is >-40 dB. The input also offers DCV for biasing an active antenna.

  • Signal Analyzer

    Anritsu Corporation

    Choose from an extensive selection of signal analyzer products from DC to 44.5 GHz and extendable to 325 GHz.With excellent total level accuracy, dynamic range and performance, Anritsu spectrum/signal analyzers not only can capture wideband signals but FFT technology supports multifunction signal analyses in both the time and frequency domains. Moreover, the built-in signal generators on some models outputs both continuous wave (CW) and modulated signals for use as a reference signal source.

  • RH Calibrator / Dew Point Generator

    Edgetech Instruments

    Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.

  • Frequency Shaped Isotropic Electric Probes

    PI-SH-FCC, PI-SH-ICNIRP - EMC Test Design, LLC

    An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.

  • THREE PHASE PORTABLE ENERGY METER CALIBRATION EQUIPMENT

    GF302D1 - Beijing GFUVE Electronics Co.,Ltd.

    The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.

  • GPS Time Synchronization Unit

    Signals & Systems India Private Limited

    GPS Time Server – GPS-DRM-1010 is a compact DIN rail mountable unit that synchronizes and maintains the timing and frequency requirement of power and process industry equipment using a signal obtained from different external sources such as GPS and GLONASS. It provides nanosecond accuracy when external time references are not available. It has a storage facility to store the system log file. It delivers NTP, SNTP, IRIG-B, PFC-Pulse, RS232 & RS485 outputs. The system enables configuration and monitoring through a Web-based application.

  • Laser Heads

    Keysight Technologies

    The laser head is the source of the laser beam used in all laser motion and position measurement systems. The primary difference between laser heads is in the velocity, reference frequency and optical output power. Other considerations are size, heat dissipation, and input power requirements. Which laser you choose depends primarily on the application in which it will be used. For example, semiconductor lithography systems typically have faster moving parts (stages), and therefore need higher velocities than machine tool applications.

  • 1207a Multi Channel Auto Switch

    Precise Time and Frequency, Inc.

    With intense competition and subscribers demanding ever more from service providers, quality and availability of service have never been more critical to maintaining and expanding your subscriber base.To complement our range of our high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new RF, Digital, and Time Code, Auto Switch / Distribution unit to insure you deliver the performance and reliability your customers demand.The ptf 1207A delivers up to eight channels of fully redundant, frequency and timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others, with NO SINGLE POINT OF FAILURE.The unit accepts two inputs on each channel from separate sources (primary and backup), monitors the inputs for signal integrity, and outputs the primary signal with no degradation of the input.If the primary input on any channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.The unit will accept up to eight channels simultaneously and independently switch on each channel.The unit also includes full remote monitoring and control via RS232 and Ethernet interfaces.

Get Help