Filter Results By:

Products

Applications

Manufacturers

Showing results: 196 - 210 of 214 items found.

  • Hardy Shaker

    HI-913 - Metrix

    This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • Production Line Acoustic Test Chamber

    PLATC - Listen Inc

    The Production Line Acoustic Test Chamber from GRAS is designed for quick and qualified acoustic test of cell phones, tablet PCs, Bluetooth speaker systems etc., including frequency response, THD, Rub & Buzz and microphone test using optional sound source. The chamber has a number of connections for injecting test and control signals to the test object (DUT).Benefits include:Repeatable testing and reliable dataEasy open/close for quick and safe change of DUTFlexible test jig for easy adjustment to new DUTFlexible microphone mounting for both front/backside speakers as well as edge-mounted speakersHigh quality, high sensitive 1/4” CCP measurementmicrophone included (G.R.A.S. 46BL)Individually calibrated frequency response** Compared to reference measurement in anechoic room

  • Quad RF Driver

    Spectronix

    The Quad RF Driver contains four independent RF channels, each with an RF synthesizer, variable attenuator, and 1W power amplifier.  The RF signal can originate from either the internal synthesizer or an external source via SMA input.  All channels have independent frequency, phase, and gain settings and can be operated in one of two modes.  The “Wideband” mode operates from 35MHz to 2GHz with a 3.472KHz resolution; over this range the frequency roll-off is approximately 0.5dB/100MHz.  “Int-N Phase Adjust” mode allows the user to set and maintain a fixed  phase relationship between all four channels.  This mode is designed to operate between 300 and 460MHz with a 2MHz resolution.  Two additional inputs are provided for an external frequency reference and digital modulation.

  • 1.533 Μm Frequency-Locked Laser

    Thorlabs, Inc.

    Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.

  • 4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function DAQ Cards

    DAQ-2500 Series - ADLINK Technology Inc.

    ADLINIK DAQ-2501 and DAQ-2502 are high-speed and high-performance analog output multifunction DAQ cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQ-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory. The DAQ-2500 series integrate up to 8-CH, 400 kS/s, 14-bit single-ended analog inputs with programmable polarity, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timer/counters.

  • 4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function PXI modules

    PXI-2500 Series - ADLINK Technology Inc.

    ADLINIK PXI-2501 and PXI-2502 are high-speed, high-performance analog output multifunction PXI modules. These devices are able to update up to 8-CH, 12-bit analog outputs imultaneously sustaining 1 MS/s. The reference sources and output polarities are programmable individually per channel. Combine this with the multiplying PXI architecture, ADLINK PXI-2500 series PXI modules can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory. The PXI-2500 series integrate up to 8-CH, 400 kS/s, 14-bit single-ended analog inputs with programmable polarity, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timer/counters.

  • 1226 Auto Switch/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new version of the ptf 1226A Auto Switch that includes an additional switch channel (now 3 channels total) of RF, and/or Digital, and/or Time Code, Auto Switching, and a full Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1226 delivers up to thirty six channels of RF, Digital or Time Code frequency and/or timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others.Analog channels include a unique output level monitoring feature to provide remote indication of rms voltage output level.The unit can accept up to three pairs of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity. In addition RF channels include analog level monitoring. If the primary input on any auto switch channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • 1211a Optical Receiver/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, LLC. has now introduced a new Optical Time Code Receiver, with Auto Switching, a full complement of time code outputs, and Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1211A delivers up to thirty six channels of Time Code outputs, including re-transmission of the optical input. The unit can accept a pair of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity.If the primary input fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • Trace-Level UV Fluorescence SO2 Analyzer

    Model T100U - Teledyne Advanced Pollution Instrumentation

    The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.

  • Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300M - Teledyne Monitor Labs

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​​

  • Gas Filter Correlation Carbon Dioxide Analyzer

    Model T360 - Teledyne Monitor Labs

    The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.​The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​​

  • ​Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer​

    Model T360M - Teledyne Monitor Labs

    The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

  • ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300 - Teledyne Monitor Labs

    The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​

  • Microwave Wideband Externally Modulated Transmitters (without RF Amp)

    MT80 (30KHz~40GHz) - Hangzhou Huatai Optic Tech. Co., Ltd.

    MT80 series microwave optical transmitter, adopts external modulation technique, are able to transmit 40GHz microwave RF signal with long distance, wide bandwidth, and flat responsibility. They provide an outstanding linearity fiber optical communication for analogue and digital wideband microwave application. Due to avoidance of using expensive coaxial cable or wave guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless; timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s and 40Gb/s high speed communication system. MT80 adopts low noise, narrow linewidth CW DFB laser as light source; LiNbO3 external modulator as signal modulation, no laser chirp, low dispersion distortion, high extinction ratio, Full-transparency operation mode. It can be applied in long distance and extra-long distance transmission after EDFA.

  • Microwave Wideband Externally Modulated Transmitters

    MT82 (30KHz~40GHz) - Hangzhou Huatai Optic Tech. Co., Ltd.

    MT82 series microwave optical transmitter, adopts external modulation technique, are able to transmit 40GHz microwave RF signal with long distance, wide bandwidth, and flat responsibility. They provide an outstanding linearity fiber optical communication for analogue and digital wideband microwave application. Due to avoidance of using expensive coaxial cable or wave guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless; timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s and 40Gb/s high speed communication system. MT82 adopts low noise, narrow linewidth CW DFB laser as light source; LiNbO3 external modulator as signal modulation, no laser chirp, low dispersion distortion, high extinction ratio, Full-transparency operation mode. It can be applied in long distance and extra-long distance transmission after EDFA.

Get Help