Filter Results By:
Products
Applications
Manufacturers
-
product
4-Channel DAQ Module
FMC176
Sundance Multiprocessor Technology Ltd.
The FMC176 is a quad channel ADC and dual channel DAC FMC. This daughter card provides four 14-bit A/D channels at 250Msps and two 14-bit D/A channels at 5.6Gsps (2.8Gsps direct RF synthesis) clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users. The FMC176 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
product
Pressure Balances
WIKA Alexander Wiegand SE & Co. KG
Pressure balances (often also referred to as mechanical dead-weight testers or primary standards) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the pressure balance an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port.
-
product
Primary Standards
Primary standards (often also referred to as mechanical dead-weight testers or pressure balances) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the primary standard an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port.
-
product
10 GHz Signal Source
YIG Series
The SC5503B and SC5502A are designed to meet demanding low phase noise applications. This is accomplished by employing a multiple phase-locked loop architecture as well as a YIG oscillator as the heart of its synthesizer. Frequency accuracy is provided by an onboard 10 MHz temperature compensated crystal oscillator (TCXO) which can be phase locked to an external reference source if required. These modules can be used as standalone CW signal sources or as LO sources for frequency conversion systems such as the SignalCore IQ modulators and demodulators. They are designed to meet the requirements of many modern applications such as wireless device testing, software-defined radio research, point-to-point radio, multi-channel coherent systems, and other academic and military programs.
-
product
Meter Testing System
ASTel
Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.
-
product
4-Channel ADC FMC Module
FMC103 – LPC
Sundance Multiprocessor Technology Ltd.
The FMC103 is a four-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC103 card provides four 12-bit 210 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC103 has the LPC (Low-Pin Count) 160-Pin connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.
-
product
8-Channel ADC Module
FMC107
Sundance Multiprocessor Technology Ltd.
The FMC107 is an eight-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC107 card provides eight 12-bit 65 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC107 has the LPC (Low-Pin Count) 160-Pin connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.
-
product
8-Channel ADC Module
FMC108
Sundance Multiprocessor Technology Ltd.
The FMC108 is an eight-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC108 card provides eight A/D 14-bit 250MSPS channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC108 has the HPC (high-pin count) connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.
-
product
Multiple-Input Multiple-Output (MIMO) Sine Test
EDM Modal Sine Testing includes a dedicated test setup and operation process flow using a single or multiple modal shakers outputting a sine wave to acquire FRF signals. The Source Output type is either Swept sine or Stepped sine. The sweep mode can be linear or logarithmic. The FRF signals of each measurement DOFs with respect to defined reference DOF will be constructed. The output drive level can be defined to run the test under no control strategy, or the response of a control channel can be specified to run the test in a closed loop.
-
product
Optical Loss Test Set (OLTS)
MaxTester 940/945
First tablet-inspired, multifunction optical loss test set (OLTS) delivering insertion loss, optical return loss and fiber length measurements at two wavelengths in five seconds via fully automated bidirectional FasTesT™ analysis. With its step-by-step reference wizard and intelligent fault diagnosis, the MAX-940/945 provides expert guidance throughout the test process to ensure immediate efficiency by first-time users while removing risk of errors or negative loss—a common source of issues when testing low loss fibers.
-
product
OPTICAL PHASE NOISE TEST AND MEASUREMENT SYSTEM
OEwaves’ HI-Q® Optical Test Measurement System utilizes a homodyne methodology for automated measurement capable of testing ultra-low phase noise laser sources. The user friendly test system is capable of rapidly measuring laser phase noise and estimating its FWHM linewidth down to < 3 Hz without complex setup or reference lasers normally required to make such a narrow linewidth measurement.
-
product
FMC-HPC ADC Board
FMC121
Sundance Multiprocessor Technology Ltd.
The FMC121 provides two 16-bit A/D channels up to 1Gsps and two 16-bit D/A channels up to 1.4 Gsps data rate with a 2.8 GSPS update rate. The design is based on Texas Instruments’ ADS54J60 Analog-to-Digital converter and Texas Instruments DAC39J84 Digital-to-Analog converter. The sample clock can be supplied externally through a coaxial connection or supplied by an internal clock source (optionally locked to an external reference) for multi-channel synchronization. An external trigger input is available for timing synchronization. The FMC121 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
product
Rubidium Frequency Standard
RFS VXI
*RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.
-
product
4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function DAQ PCI Express Cards
DAQe-2500 Series
ADLINK DAQe-2500 series are high-speed and high-performance analog output multi-function DAQ PCI EXpress cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQe-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory.
-
product
Meter Test & Calibration
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of products for meter test and calibration including portable power source, standard reference meter and meter test system. All products are accredited to the highest production standards with different options of measurement accuracy (class 0.05 and class 0.1).These enable them to cover different applications for test and calibration of different types of energy meters, electric transducers, indicating meters and so on.
-
product
Phase Noise Testers / Signal Source Analyzers
7000 Series
Berkeley Nucleonics Corporation
The 7000 series is an all-in-one integrated solution that offers an indispensable set of low-noise phase measurement functions. Offering both Absolute and Additive(residual) measurement capabilities in one unit at no additional cost, the 7000 series is the most flexible solution on the market. The instrument comprises a two-channel, cross-correlation system with two internal, tunable references sources that also allows measurements with externally sourced references. We offer three platform options for the 7000 Series Phase Noise Testers: the 7070 1 MHz to 7 GHz, the 7300 1 MHz to 26 GHz, 7340 1 MHz to 40 GHz, 7350 1 MHz to 50 GHz, and the 7360 1 MHz to 65 GHz.
-
product
Low Power Potentiostats
Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg
-
product
RF Calibration Accessories
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
product
FPGA Mezzanine Card
FMC165
The FMC165 provides two 14-bit analog-to-digital (A/D) channels supporting RF sampling at 2.6 GSPS and one 14-bit digital-to-analog (D/A) channel with sampling rates up to 5.2 GSPS (2.6 GSPS direct RF synthesis). The converters are clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
product
Reference Transmitter
81492A
Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.
-
product
Gas Filter Correlation CO Analyzer
Model T300
Teledyne Advanced Pollution Instrumentation
DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.
-
product
1231a Very High Frequency Distribution
Precise Time and Frequency, Inc.
The ptf 1230A(1U)/1231A(2U) GPS L-Band RF Distribution amplifiers provide high performance GPS signal references for laboratory or systems use. In most applications the low noise and signal gain capability of the units will provide userswith a robust GPS signal source for lab or system requirements.The ptf 1230A/1231A uses individually buffered output stages and insures maximum isolation between the individual outputs. The ptf 1231A offers 12 outputs. Options are available for a 2U/3.5” version (ptf 1230A) with 24 outputs.Isolation from output to output is >-40 dB. The input also offers DCV for biasing an active antenna.
-
product
Signal Analyzer
Choose from an extensive selection of signal analyzer products from DC to 44.5 GHz and extendable to 325 GHz.With excellent total level accuracy, dynamic range and performance, Anritsu spectrum/signal analyzers not only can capture wideband signals but FFT technology supports multifunction signal analyses in both the time and frequency domains. Moreover, the built-in signal generators on some models outputs both continuous wave (CW) and modulated signals for use as a reference signal source.
-
product
RH Calibrator / Dew Point Generator
Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.
-
product
Frequency Shaped Isotropic Electric Probes
PI-SH-FCC, PI-SH-ICNIRP
An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.
-
product
THREE PHASE PORTABLE ENERGY METER CALIBRATION EQUIPMENT
GF302D1
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
product
GPS Time Synchronization Unit
Signals & Systems India Private Limited
GPS Time Server – GPS-DRM-1010 is a compact DIN rail mountable unit that synchronizes and maintains the timing and frequency requirement of power and process industry equipment using a signal obtained from different external sources such as GPS and GLONASS. It provides nanosecond accuracy when external time references are not available. It has a storage facility to store the system log file. It delivers NTP, SNTP, IRIG-B, PFC-Pulse, RS232 & RS485 outputs. The system enables configuration and monitoring through a Web-based application.
-
product
Laser Heads
The laser head is the source of the laser beam used in all laser motion and position measurement systems. The primary difference between laser heads is in the velocity, reference frequency and optical output power. Other considerations are size, heat dissipation, and input power requirements. Which laser you choose depends primarily on the application in which it will be used. For example, semiconductor lithography systems typically have faster moving parts (stages), and therefore need higher velocities than machine tool applications.
-
product
Single Phase Site Energy Meter Test Instrument Type KP-P1001-A
Bofa Instrument & Equipment Co., Ltd
Single phase site energy meter test instrument type KP-P1001-A (without voltage and current source) is an ideal instrument to test all kind single phase energy meters accuracy below 1.0, especially for meters on site. During tests, the tested meter must be on load condition (that means the tested meter must be working). The instrument tests the errors by comparing energy impulse from the tested meter with energy impulse from the reference meter inside the instrument.