Showing results: 166 - 180 of 1157 items found.
-
Macom Technology Solutions Holdings Inc.
MACOM's MSPD Series Integrates an SRD reference frequency multiplier, coupling capacitors and a Schottky diode microwave sampler / phase detector in a 0.075” by 0.100” hybrid. They are used to phase lock microwave oscillators up to 22 GHz to a much lower reference frequency by deriving a locking voltage from the sampled RF and the multiplied reference.
-
AOSense
A compact, mechanically-robust laser frequency reference.
-
Model 7894 -
Pentek, Inc.
Provides sample clock for up to four separate PCIe Cobalt or Onyx boards, Locks to user-supplied 10 MHz reference clock or on-board reference, OCXO provides an exceptionally precise clock.
-
AnaPico Ltd
The APSYN and APUASYN series consist of low phase-noise synthesizers operating up to 40 GHz. The modules have a MHz frequency resolution. The internal high-stability reference can be phase-locked to an external programmable reference.
-
MKS Instruments
These general performance Baratron® differential capacitance manometers measure the difference in pressure between the inlet tube and the reference cavity. The reference cavity can be connected to any pressure or vacuum source, or be open to local atmosphere.
-
CGE -
York EMC Services Ltd
These reference signal source generate a broadband radiated and/or conducted output up to 40 GHz. When used as a verification reference source, the known output allows unknowns within systems or components to be measured or calculated.
-
QA350 -
QuantAsylum
The QA350 relies on a built-in reference to calibrate the ratio between the hi and low ranges. If you have a preferred lab reference, you may use that it to improve the QA350 accuracy beyond the indicated +/- 400 PPM. For example, various vendors on eBay can provide calibrated +/-30 PPM 5 or 10V voltage references that can be used to set the ultimate accuracy of the QA350 to under 50 PPM at room temperature.
-
DOWNCONVERTER 10 GHz VXI -
Holding Informtest
The DOWNCONVERTER 10 GHz design assumes its use in closed mobile complexes for field testing of communications equipment. To do this, the device has applied advanced solutions to reduce the phase noise of the output signal in conditions of increased vibration and temperature. The device has a temperature-stabilized reference frequency generator with the ability to output a reference frequency signal. Also, it is possible to operate from an external reference generator.
-
TimeTech GmbH
Timetech reference generators, phase comparators, and synchronized oscillators.
-
HGH USA
Blackbodies are reference sources used for testing infrared systems.
-
6513D -
Peaceful Thriving Enterprise Co Ltd
This tester can measure the boil point of the brake fluid. It can obtain the wet boiling temperature of the brake fluid for technician as a reference for maintenance. It can be the reference when technician is going to change the brake fluid.The testing data print by Bluetooth printer.
-
SICK Sensor Intelligence
Versatile, compact and flexible – Incremental encodersIncremental encoders are used when retention of absolute position upon power loss is not required. These encoders provide information about the position, angle and number of revolutions. The number of lines per revolution determines the resolution. The current position can be determined by counting these pulses from a reference point. Upon activating the machine, a reference run to the reference point is required to determine the absolute position of the encoder.
-
P014 -
AMETEK Sensors, Test & Calibration
The P014 hydraulic jack pump (System E) is an extremely effective pressure pump designed for easy, controlled, high pressure generation. Each comparator includes a 4 connection manifold, which can be used for the reference indicator, the device under test, a fine adjust, an isolation valve, or a fluid reservoir. The adjustable reference pressure port lets you set your reference gauge at the best viewing angle.
-
-