Showing results: 256 - 270 of 1178 items found.
-
Zurich Instruments AG
The Zurich Instruments Boxcar Averager operates as a high-speed digitizer synchronized to a reference oscillator that is phase-locked to the periodicity of the experiment. In the case of the laser repetition rate, for example, every data sample recorded at the input can be associated with the phase of the experiment and the signal components not synchronized with the experiment are strongly suppressed. The implementation based on an external reference signal removes the trigger jitter, and the digital realization enables a dead-time-free operation.
-
6R Series -
Mors Smitt Group
The 6R MATRIX range was developed to provide design engineers with a modular system of auxiliary relays to meet specific system configurations. The versions described in the following cross reference table have pre-defined functional & contact configurations to offer the following advantages:*Simple to specify & order*Lower cost due to model rationalization*Direct cross reference to other manufacturers models*Standardized wiring details
-
S97084B -
Keysight Technologies
The S97084B tunes the analyzer’s receivers to the output frequency of the converter under test without the need for access to internal LOs or a common reference signal
-
DAQM901A -
Keysight Technologies
20 Channel Multiplexer (2/4-wire) Module. High voltage switching capability of up to 300 V and built-in thermocouple reference junction.
-
Applied Meters, a.s.
The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase
-
AD-100 -
Com-Power Corporation
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
Arrival 3D, Inc.
The reference data may come in the form of a table, with values at specific points or features, a cad model, or 3d scan. 3D inspection services may require datum measurements, where the part to be inspected is located in a fixture that is specifically designed to orient the part by an ordered method. In some cases, the part may have features that are designed specifically to be referenced by datums, if no functional feature of the part provides a clear reference.
-
Advantech Co. Ltd.
Advantech Application Board is application-oriented development board which customers can view as not only a ready-for-use carrier board but also a development board for verification. The Application Board saves time and effort during planning stages and provides a schematic reference to reduce design effort at the development stage. Moreover, the Application Board inherits high integration features, provides a schematic reference and further emphasizes the characteristics of COM.
-
HGH USA
Compact thermal camera reference source. Compatible with all thermography cameras on the market and IEC 80601-2-59 compliant. Available now, ready to ship.
-
63800-7950 -
Molex, Inc.
The crimp force monitor measures the force signature of a crimped terminal and compares it to a reference crimp. Depending on the limits programmed, the measurement will pass, fail, or be suspect.
-
-
AMETEK Sensors, Test & Calibration
Using the external reference sensors on the temperature calibrators or indicators to measure the true temperature, AmeTrim can perform a fully automatic calibration and adjustment of the internal sensor.
-
S95084B -
Keysight Technologies
The S95084B software tunes the analyzer’s receivers to the output frequency of the converter under test without the need for access to internal LOs or a common reference signal.
-
16820-100 -
M. C. Miller Company
The Model PS1 under tank probe is designed to be used in conjunction with customer-supplied ¾” National Pipe Thread (NPT) PVC piping and the product has a ¾” (NPT) threaded end that accepts a standard coupling. Any number of pipe pieces can be combined via couplings to provide the required probe insertion length under a tank. The probe can be combined with any standard reference electrode with a ¼ x 20 threaded fitting, including the RE-5, RE-5C and RE-7 portable reference electrodes. Reference electrodes are sold separately. The sealed cable to be fed through a customer-supplied PVC pipe comprises #16 AWG wire with red colored PVC insulation and the wire length can be selected via the radio buttons in the field below.
-
VCH-323 -
VREMYA-CH JS Company
- Monitoring of the metrological characteristics in the production of precision signal sources, including crystal oscillators and quantum frequency standards - Time and frequency references - Scientific research measurements