Showing results: 346 - 360 of 1157 items found.
-
RT4 -
Rhopoint Instruments
This comparative test works by abrading a printed sample against a reference material under known conditions. The results can be used to identify alternative substrates, better ink and coating formulations or the suitability of finished cartons, films or printed books, magazines and promotional materials.
-
MSXB 024 -
Microstar Laboratories, Inc.
Analog Input Expansion Termination Board expands 8 analog input lines to 32 analog input lines and provides connection points for each line. Each of the two models has an onboard temperature reference sensor for cold junction compensation.
-
K Series3D -
Vi Technology
K Series and K Series3D are the reference in Automated Optical Inspection (AOI), allowing 2D and 3D inspection with very low false calls rate, for both pre-reflow and post-reflow. They are the most powerful gatekeepers to guarantee high quality level for the assembled PCB.
-
BioLogic
High-precision, highly-stable battery cyclers that feature advanced EC techniques, five electrode connections and powerful analysis tools. MPG Battery Testers give users real reference electrode management, making them perfect instruments for research and development applications.
-
1740 -
TEGAM Inc.
Basic Accuracy: 0.02%Measurement Speed: 10 msRange : 20 m to 20 MResolution : 1 Programmable reference currentsGPIB, RS-232 (model 1740/GPIB) and PLC compatibilityKelvin Klips, Spade Lugs or Kelvin Probes availableEasy to operate and easy to integrate1-year warranty
-
34307A -
Keysight Technologies
The Keysight 34307A is compatible with the Keysight 34970A Data Acquistion/Switch Unit. The 34307A can also be used with the Keysight 34401A, 34460A or 34461A, however, an external program is required to convert the voltage measurements to temperature and an ice bath or electronic reference junction must be used.
-
VS-SDC -
Ametek Scientific Instruments
Scanning Droplet System (SDC) uses a compact peristaltic pump to force electrolyte through a small diameter tube and into a specifically designed head. This PTFE-based SDC head is machined to allow electrolyte to flow past an installed Reference Electrode and then to a port at the base of the head.
-
V380 -
Highland Technology, Inc.
The V380 is a VME/VXI compatible eight-channel strain-gauge signal conditioner which is optimized for load-cell weighing applications. The module includes tare (zero reference), DSP-based high-order filtering, averaging, triggered weighing, and other functions not commonly available in conventional strain-gauge signal conditioners.
-
PCT200i -
Ponovo Power Co., Ltd.
PCT200 series CT test set (CT Analyzer) is a current transformer test equipment specially designed for current transformer characteristic test and with additional PT test functions for reference test. PCT200i owns more test items and higher technical parameters.
-
XCLK1 -
Curtiss-Wright Defense Solutions
High-speed analog IO acquisition systems need a high quality master reference sample clock.Accurate synchronization in the 100MHz and up frequency domains is not easy and it’s a critical performance limiting factor if not done well. The XCLK1 multi-channel clock generator solves these problems.
-
Control Parameters -
ZETLAB Company
Pre-test of the system for the purpose of evaluating the optimal parameters to be used for test performance Preparation for vibration testing is an important and labor-consuming process. It is attributed to the fact, that correct mounting of the transducers on the test specimen and selection of the reference transducer are crucial factors for the successful performance of the testing procedure.
-
P-6 -
Sonel S.A.
SONEL P-6 has all the features that characterize the P-4 Voltage Tester and P-5 Voltage Tester. In addition, the P-6 model has the phase identification function which allows to verify the phase compatibility (and its overtaking or delay) against the phase at the reference object.
-
SACP-RACP -
Computer Conversions Corporation
Computer Conversions Synchro-Resolver to ACP/ARP Converters accept choice of synchro-resolver input options, power input, and mounting configuration, converts synchro/resolver input into ACP (Azimuth Change Pulse) and ARP(Azimuth Reference Pulse) type outputs suitable for 75 ohm drive.
-
Accelerometer Array -
Seismic Source Co.
*24-channel input interface for DAQLink-III acquisition system (23 for accelerometers and one for True Reference)*Computes accelerometer weighted sum using input array*Controlled state of current supplies for external accelerometers*LED status indication of every accelerometer input*Differential outputs to the acquisition system*Input channel impedance of 1 Mohm*Bandwidth: 0.1 - 5000 Hz*Crosstalk: -100 dB*Phase tolerance of channels: ±0.2 deg*10 mA current supply for every accelerometer channel*Max input signal: ±10 V p-p (True Reference), ±2.8 V p-p (Accelerometer input)*Power supply: 9 - 18 V
-
TS23 -
Calmet Smart Calibration Devices
Three phase reference standard of accuracy 0.02% (or 0.04%). It makes possible electricity meters testing on the site or in the laboratory up to 3x120A/600V