Filter Results By:

Products

Applications

Manufacturers

Showing results: 571 - 585 of 1157 items found.

  • Fourier Transform Infrared Spectroscopy (FTIR)

    Rocky Mountain Laboratories, Inc.

    FTIR Analysis is used to analyze organic materials. Bulk and small particle materials can be analyzed. FTIR microscopy allows for the identification of particle as small as 10 µm. Determination of unknown materials is facilitated by spectral matching to a library of over 250,000 reference spectra.

  • Portable Connector End Face Geometry Interferometer

    Thorlabs, Inc.

    Thorlabs’ Vytran® Connect-Chek® Interferometer automatically and precisely measures radius of curvature, apex offset of polish, and fiber undercut or protrusion on any PC or APC, single-fiber connector. The CC6000 interferometer uses a non-contact tilted-phase-analysis technique for fast, reliable measurements of connector end faces. This compact interferometer has a carrying handle and must be attached to a desktop or laptop computer (not included) with a standard USB 2.0 port for operation. The included CC6000 software, which is used to control the interferometer, can be installed on a computer with the minimum requirements in the table below. Designed for use in both the factory and the field, this interferometer provides crucial quality information needed to assure long-term performance of fiber optic connectors. One CC250P Mount for Ø2.50 mm PC Connectors and one RT250P Reference Tool for calibrating the CC250P mount are included with the CC6000 interferometer; mounts and reference tools that enable measurement of other PC or APC, single-fiber connectors are available separately below. When used with an appropriate mount for APC connectors, the CC6000 interferometer is also capable of measuring the APC angle and key error.

  • SparkFun GNSS Timing Breakout

    ZED-F9T (Qwiic) - SparkFun Electronics

    The SparkFun GNSS Timing Breakout offers a unique entry into SparkFun's geospatial catalog featuring the ZED-F9T GNSS receiver from u-blox. The ZED-F9T provides up to five nanosecond timing accuracy under clear skies with no external GNSS correction making it perfect for applications where timing accuracy is imperative. Need an extremely accurate time reference to maximize the efficiency of your IoT network of 5G devices? The ZED-F9T GNSS Timing Breakout could be the perfect solution.

  • Time & Frequency Distribution Amplifiers

    Brandywine Communications

    Brandywine offers a wide range of high quality, state of the art signal timing distribution amplifiers, all with very low phase noise. These precision timing signal distribution amplifiers offer a variety of time and frequency signals and interface formats including IRIG A, IRIG B, Have Quick, 1PPS, as well as low phase noise reference frequencies. All of our distribution amplifiers feature dual inputs with automatic failover and multiple independently buffered outputs.

  • 5G Core (5GC) for Small Cells and Private Networks

    SmallCellCORE-5G - CommAgility Limited

    SmallCellCORE-5G provides a 5G Core (5GC) for 5G small cells and private networks. SmallCellCORE-5G joins CommAgility's existing 5G stack, PHY and reference chain software, to create an integrated solution with the company's hardware platforms.With SmallCellCORE-5G, developers can now build their 5G network with a complete set of hardware and software from CommAgility – already tested and integrated. Development is quicker and easier, and risk is reduced by working with a proven solution, backed up by CommAgility's expert, global support.

  • 16-Channel DAC FMC Module

    FMC216 – HPC - Sundance Multiprocessor Technology Ltd.

    The FMC216 is a sixteen-channel DAC FMC Daughter Card which is fully compliant with the VITA 57.1-2008 standard. The FMC216 provides sixteen D/A 16-bit 312.5Msps (2.5Gsps with x8 interpolation) channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC216 has the HPC (high-pin count) connector, front panel I/O, and is conduction cooled capable.

  • Ultra High Power Precision Shunt Resistor

    UHPS - RARA Electronics Corporation

    *Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies

  • Network Cable Tester

    NCT-500 - ShinewayTech

    ShinewayTech NCT-500 Network Cable Tester,Functions ranging from ISO / OSI reference model physical layer, link layer, network layer multiple detection. One machine in hand, which can quickly locate network faults and determine the link quality.

  • Chlorophyll Concentration

    Apogee Instruments, Inc.

    Linear OutputThe Apogee chlorophyll concentration meter is calibrated to measure chlorophyll concentration in leaves with units of mol of chlorophyll per m2. This eliminates the problems with relative indexes of chlorophyll concentration.For reference and comparison purposes, the Apogee meter also outputs relative units [CCI or SPAD] if desired.For details see: Parry, C., Blonquist Jr., J.M., & Bugbee, B. 2014. In situ measurement of leaf chlorophyll concentration: analysis of the optical/absolute relationship. Plant, Cell and Environment 37:2508-2502.

  • FMC Dual ADC 12-bit 2.6 GSPS, Single DAC 16-bit 12 GSPS

    FMC250 - Vadatech Inc

    The FMC250 is an FPGA Mezzanine Card (FMC+) per VITA 57.4 specification. The board has dual ADC and single DAC. The FMC250 utilizes dual AD9625 ADCs providing 12-bit conversion rates of up to 2.6 GSPS and a single DAC (AD9162 or AD9164) providing 16-bit conversion rates of up to 12 GSPS. The analog input, digital output, clock and trigger interfaces of the FMC250 are routed via SSMC connectors. The internal clock frequency is programmable and the clock is capable of locking to an external reference.

  • Multi-format Video Generator

    LT 4600A - Leader Electronics Corp.

    The LT 4600A multi-format video generator is a compact, 1U half-rack size SDI video signal generator that supports the triple-rate SDI (3G-SDI/HD-SDI/SD-SDI) format. In addition to test pattern output including color bars and SDI check fields, the LT 4600A is equipped with numerous features such as ID characters, QVGA logo marks, safety area markers, audio embedding, genlock function for external reference input signals, and three analog black signal outputs.

  • Optical Power and Wavelength Meter

    OMM-6810B - Newport Electronics

    The OMM-6810B is a power and wavelength meter capable of simultaneously measuring the optical power and wavelength of a laser source. A wide variety of measurement heads cover wavelength ranges from 350 to 1650 nm for power ranges of up to +40dBm or 10W.This meter has standard features such as logarithmic or linear display modes, auto ranging, user calibratable offset, reference measurement capability, analog output and IEEE-standard GPIB interface to make this instrument a cost effective laser diode development or production test tool.

  • Single Cell Hardware

    Fuel Cell Technologies, Inc

    A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).

  • Sound Level Calibrator

    521 - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

  • Sound Level Calibrator

    511E - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

Get Help