Showing results: 616 - 630 of 1177 items found.
-
FMC250 -
Vadatech Inc
The FMC250 is an FPGA Mezzanine Card (FMC+) per VITA 57.4 specification. The board has dual ADC and single DAC. The FMC250 utilizes dual AD9625 ADCs providing 12-bit conversion rates of up to 2.6 GSPS and a single DAC (AD9162 or AD9164) providing 16-bit conversion rates of up to 12 GSPS. The analog input, digital output, clock and trigger interfaces of the FMC250 are routed via SSMC connectors. The internal clock frequency is programmable and the clock is capable of locking to an external reference.
-
LT 4600A -
Leader Electronics Corp.
The LT 4600A multi-format video generator is a compact, 1U half-rack size SDI video signal generator that supports the triple-rate SDI (3G-SDI/HD-SDI/SD-SDI) format. In addition to test pattern output including color bars and SDI check fields, the LT 4600A is equipped with numerous features such as ID characters, QVGA logo marks, safety area markers, audio embedding, genlock function for external reference input signals, and three analog black signal outputs.
-
OMM-6810B -
Newport Electronics
The OMM-6810B is a power and wavelength meter capable of simultaneously measuring the optical power and wavelength of a laser source. A wide variety of measurement heads cover wavelength ranges from 350 to 1650 nm for power ranges of up to +40dBm or 10W.This meter has standard features such as logarithmic or linear display modes, auto ranging, user calibratable offset, reference measurement capability, analog output and IEEE-standard GPIB interface to make this instrument a cost effective laser diode development or production test tool.
-
Fuel Cell Technologies, Inc
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
521 -
ACO Pacific, Inc.
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
511E -
ACO Pacific, Inc.
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Fluke Calibration
Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.
-
Omron Industrial Automation
Ultrasonic Reflective Sensors have a user friendly adjustable sensing distance from 0.3m to 3m, operating under stable operation with problems of background interference. This simple-to-use sensor has a built-in unstable operation check function that allows for easy adjustment to proper mounting direction. The tough, rugged mono-block, self-contained construction also incorporates synchronous selector and reference pulse input and output terminals makes this sensor ideal for multiple parallel operation use without the problems of mutual interference.
-
U6220A -
PICOTEST Corp.
The Picotest U6200A also provides great features including Frequency & Ratio (11Digits/Sec.), Time interval, Period (2.5 ns to 1000s), Duty Cycle, Pulse Width, Rise/Fall Time, Peak Volts (100 Hz~300 MHz), Phase, Totalize, Temperature Stability (< 1 PPM), Aging Rate (< 2 PPM per year), timebase reference channel (Figure-2) and complete Front-End Isolation. Moreover, it offers 20 memory locations (Figure-3) for storing frequently-used operations.
-
SD7500CD -
Sensorex
Continuous online pH monitoring in wastewater and coating industrial applications leads to contamination and eventually requires sensors to be replaced. A differential pH sensor utilizes a measurement technique designed to extend the working lifetime of sensors in challenging applications. Replacing the sensor reference (salt bridge) and buffered electrolyte solution can prevent sensor replacements, saving time and money. Our SD7500 Series features a combination sensor output; these differential pH sensors can be used with any conventional pH/ORP transmitter.
-
FMC142 -
Sundance Multiprocessor Technology Ltd.
The FMC142 is an analog-to-digital (A/D) and digital-to-analog (D/A) FMC daughter card that provides two 16-bit A/D channels at 370MSPS and two 16-bit D/A channels at 2.5GSPS which can be clocked by an internal clock source (optionally locked to an external reference) or by an externally-supplied sample clock. A trigger input is also available for customized sampling control. The FMC142 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1-2010). It offers front panel analog I/O access and can be used in a conduction-cooled environment.
-
FMC176 -
Sundance Multiprocessor Technology Ltd.
The FMC176 is a quad channel ADC and dual channel DAC FMC. This daughter card provides four 14-bit A/D channels at 250Msps and two 14-bit D/A channels at 5.6Gsps (2.8Gsps direct RF synthesis) clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users. The FMC176 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
StopLight -
StopLight
The best way to model, document, and test web APIs. Model complex APIs faster than ever. Stoplight consists of four primary components; API designer, hosted documentation, the new scenarios component, and Prism. Stoplight API designer automatically discovers APIs from HTTP traffic which developers can reference to build new APIs. Developers can use the API designer to build APIs based on imported API definition files such as RAML and Swagger, and build APIs from scratch.
-
3440A -
Ballentine Laboratories, Inc.
The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.
-
Model N300 -
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.