Showing results: 811 - 825 of 1157 items found.
-
Bertin Instruments
Our dedicated range of products and accessories has been especially designed to fit these needs and to provide accuracy in the following application fields: Short and long-term monitoring of radon concentration indoor and outdoor, water and soil gas analysis Radon surveillance and mitigation at workplaces (according to valid radiation protection regulations) Geological survey, e.g. vulcano watching, earthquake surveillanceAlphaGUARD products reputation is worldwide recognized, as a reference device for calibration for active and passive radon detectors.
-
MS 1527 -
Meltronics Systemtech
The Semi-ATE is used for testing the analog ADC. It shall carry out the functional test on ADC analog module. The ATE shall have all necessary IO signals on the connector end. The semi-ATE can carry out the functional tests on ADC analog module with host PC or laptop. It provides +15V, -15V, +5V & -5V to module and +2.5V high precision reference voltage. It can able to control keysight N6700B Power supply mainframe using RS422 interface.
-
784539-01 -
NI
The NI-9775 provides referenced single-ended analog inputs with two timing modes for applications such as fault detection in electrical transmission lines or structural failure events. You can use the NI-9775 to measure finite samples up to 20 MS/s/ch to capture fault detections or to measure continuously at up to 4 MS/s. You also can use the built-in analog reference trigger to assist with high speed phenomena. Additionally, the NI-9775 supports waveform streaming at a lower sample rate.
-
PD5033 -
INSTOCK Wireless Components, Inc
PD5033 is an IP67 outdoor, weather resistant, DC blocking, three way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5033 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 3 way power divider input rating tables for additional power handling info.
-
PD5023 -
INSTOCK Wireless Components, Inc
PD5023 is an IP67 outdoor, weather resistant, DC blocking, two way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5023 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 2 way power divider input rating tables for additional power handling info.
-
PD5123 -
INSTOCK Wireless Components, Inc
PD5123 is an IP67 outdoor, weather resistant, DC blocking, two way, RF broadband, 50 ohm, power divider, power combiner furnished with SMA type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5123 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 2 way power divider input rating tables for additional power handling info.
-
PD5043 -
INSTOCK Wireless Components, Inc
PD5043 is an IP67 outdoor, weather resistant, DC blocking, four way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5043 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 4 way power divider input rating tables for additional power handling info.
-
PD5143 -
INSTOCK Wireless Components, Inc
PD5143 is an IP67 outdoor, weather resistant, DC blocking, four way, RF broadband, 50 ohm, power divider, power combiner furnished with SMA type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5043 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 4 way power divider input rating tables for additional power handling info.
-
6109A / 7109A -
Fluke Calibration
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
Model 52663 -
Pentek, Inc.
- Complete GSM channelizer with analog IF interface- Four 180 MHz 16-bit A/Ds- Two banks of 375 DDCs for upper GSM band- Two banks of 175 DDCs for lower GSM band- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express Gen. 2 x4- 3U VPX form factor provides a compact, rugged platform- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Model 71663 -
Pentek, Inc.
- Complete GSM channelizer with analog IF interface- Four 180 MHz 16-bit A/Ds- Two banks of 375 DDCs for upper GSM band- Two banks of 175 DDCs for lower GSM band- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express Gen. 2 x8- RoHS Compliant Lead-Free Version Available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
PI-SH-FCC, PI-SH-ICNIRP -
EMC Test Design, LLC
An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.
-
AI-CCS-DM-G Rev A -
Applied Image, Inc.
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
GF302D1 -
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
TCG1 -
NG Systems Ltd
This generator provides a standard 75O, 1-volt p-p; PAL encoded CCIR video signal for the testing of monitors and other CCTV equipment. The Test Card Generator TGC1 may display one of four test patterns , (i) Colour bars with reference, (ii) Red Raster, (iii) Peak White Raster and (iv) Composite Test Card (see picture below). The Test Card Pattern incorporates many of the attributes of broadcast test patterns for the evaluation and setting up of CCTV video equipment.