Showing results: 1831 - 1845 of 4029 items found.
-
42-784B-022 -
Pickering Interfaces Ltd.
The 40-784B-022 (PXI) and 42-784B-022 (PXIe) are dual SP6T failsafe 18 GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Mors Smitt Group
The D-dock system consists of a D-dock Test Block which is put between the existing relay socket and the existing D-U plug-in relay. All 14 relay-pins are wired to the Break-Out Box enabling to connect measuring equipment like multimeters, scope meters or data analyzers to log operations during longer period. This makes fault finding easy. The D-dock fits in tightly packed relay panels and small cabinets. It can operate unattended enabling normal passenger operating service.
-
40-320-001 -
Pickering Interfaces Ltd.
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
40-320-101 -
Pickering Interfaces Ltd.
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
Keithley S46 -
Tektronix, Inc.
S46 and S46T Microwave Switch Systems are designed to simplify the automated switching needed to test a wide range of RF and telecommunication products and devices. The S46 can control 32 relay contacts in a package as small as a 2U high (3.5 in) full-rack enclosure. Choose the System 46T if your application requires a terminated configuration. It builds on the design technology of the unterminated System 46. The System 46T accommodates up to eight terminated SPDT coaxial microwave relays and four terminated multi-pole coaxial microwave relays.
-
782835-37 -
NI
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
782835-38 -
NI
256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
782835-39 -
NI
256-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2739 is a high‐density 16x16 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
780587-25 -
NI
64‐Channel, 2 A, Multibank, 2‐Wire PXI Multiplexer Switch Module —The PXIe‑2525 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 2‑wire multiplexer configurations: 16 bank 4x1, octal 8x1, quad 16x1, dual 32x1, and 64x1. The PXIe‑2525 also features onboard relay counting for relay monitoring.
-
782384-01 -
NI
512-Crosspoint PXI Matrix Switch Module—The PXIe‑2532B is a high-density PXI matrix switch module built to serve high‑channel‑count automated test systems. Featuring compact reed relays with switching speeds up to 2,000 cycles/s, the PXIe‑2532B can be configured in more than 10 matrix topologies by using different terminal block accessories. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
778572-36 -
NI
544-Crosspoint, 1-Wire PXI Matrix Switch Module—The PXI‑2536 is a high-density 8x68 PXI matrix switch module that is ideal for routing low-power DC signals in validation test systems of mass produced devices such as semiconductor chips and printed circuit boards (PCBs). Featuring FET relays, the PXI‑2536 offers unlimited mechanical lifetime and switching speeds up to 50,000 crosspoints/s. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
782383-01 -
NI
512-Crosspoint PXI Matrix Switch Module—The PXI‑2532B is a high-density PXI matrix switch module built to serve high‑channel‑count automated test systems. Featuring compact reed relays with switching speeds up to 2,000 cycles/s, the PXI‑2532B can be configured in more than 10 matrix topologies by using different terminal block accessories. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
780587-24 -
NI
128‐Channel, 2 A, Multibank, 1‐Wire PXI Multiplexer Switch Module —The PXIe‑2524 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 1‑wire multiplexer configurations: 16 bank 8x1, octal 16x1, quad 32x1, dual 64x1, and 128x1. The PXIe‑2524 also features onboard relay counting for relay monitoring.
-
AD-7110 -
ADEX Urzadzenia Pomiarowe
The instrument AD-7110 is designed to measure, with high accuracy, resistance conductive elements of power devices: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of screw connections, crimp, welded state of the contacts of switches and relays current up to 100 A .
-
WF 3154 C-Series -
WireFlow AB
The WF 3154 from WireFlow is a 4-channel Fault Injection Module for Compact RIO. Each channel provide three solid state relays that can be used to create electrical fault conditions like: Open circuit, Short circuit to battery, Short circuit to ground.