Filter Results By:

Products

Applications

Manufacturers

Relay

electromechanical or semiconductor switches.

See Also: General Purpose Switch


Showing results: 406 - 420 of 4056 items found.

  • PXI Replacement Microwave Multiplexer Relay

    40-785-751-R - Pickering Interfaces Ltd.

    Pickering Interfaces PXI Microwave multiplexer modules are suitable for switching 50Ω signals up to 40GHz. The 40-785 is available as a single or dual 6 channel multiplexer, with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.

  • Microcomputer Six-phase Relay Test Set

    Weshine Electric Manufacturing Co., Ltd

    It is a new miniaturized microcomputer relay protection tester realized by extensively listening to users' opinions, summarizing the advantages and disadvantages of similar domestic products, and fully using modern advanced microelectronic technology and devices. It adopts the advanced structure of stand-alone operation, and can also be connected to a notebook computer.

  • AC Filament Switching and Line Relays

    Mors Smitt Group

    *Heavy duty Elkonite contact tips*AC and DC versions available*AC versions available with or without internal rectifier PCB*Automated vision system and operator inspection*Comprehensive automated end of line testing*Test Certificates supplied with each relay*Certificate of Conformity supplied with each order*Recertification and repair services available

  • DC Filament Switching and Line Relays

    Mors Smitt Group

    *Heavy duty Elkonite contact tips*AC and DC versions available*AC versions available with or without internal rectifier PCB*Automated vision system and operator inspection*Comprehensive automated end of line testing*Test Certificates supplied with each relay*Certificate of Conformity supplied with each order*Recertification and repair services available

  • Solid-State Relays Packaged in a 16-Pin DIP

    Series C75-2 - Teledyne Defense Electronics Relays & Coax Switch

    ​​Series C75-2 solid-state relays are packaged in a 16-pin DIP, with surface-mount or through-hole mounting available. They utilize a power FET switch that is protected against overload and short-​circuit currents. 2S versions provide an open-collector trip status feedback to the relay’s control side. 2SH versions add an internal transient voltage suppressor for inductive loads.MSL 6​C75 relays are controlled with 4.5-5.5VdcC = Through-hole mount SC = Surface mountAvailable options include:C75-2 1A, 60Vdc Load; short-circuit protectionSC75-2 1A, 60Vdc Load; short-circuit protection C75-2S 1A, 60Vdc Load; short-circuit protection and trip satus​SC75-2S 1A, 60Vdc Load; short-circuit protection and trip status C75-2SH 1A, 60Vdc Load; short-circuit & transient voltage protection, and trip status​SC75-2SH 1A, 60Vdc Load; short-circuit & transient voltage protection, and trip status

  • Mechanical Signal Relays (2A Or Less)

    Panasonic Industrial Devices Sales Company of America

    Mechanical Relays that can switch up to 2A. Ideal for low load switching, signal control, etc. Features include gold contacts, stable contact resistance, fully sealed construction, Form C contact arrangement, available latching and low operating power, and compact size for optimal board space usage.  Applications include: AC Control, Communications, Security, Measurement Equipment, Audio Visual Devices and Automotive.

  • COMPUTERIZED AUTOMATIC RELAY TEST SYSTEM

    CVRT-S16 - Vasavi Electronics

    CVRT-S8 & S16 are ideal for automatic testing of ELECTRO MECHANICAL AND READ RELAYS (only DC relays) both for static and dynamic characteristics. This system scans at one stroke, all the parameters of the relay as per definition of test procedure. The test sequence can be pre-programmed and stored in the disk. You can select the tests as per your requirement. Can include or exclude the test and you can have several options to match your test definitions. Semi skilled person can be engaged for actual testing, as he need not make any settings and need not interpret the readings. The system conducts the tests and gives PASS / FAIL indication on overall test results. If a printer is connected, each test result will be printed.Test Parameters : -> Coil Resistance.-> PickUp/Pull In /Operating Voltage or Current Linear Ramp Method or Step Method.-> Measure Pickup Contact Gap FBB-LBB V or mA-> DropAway/Drop Out/Release Voltage or Current Linear Ramp Method or Step Method.-> DropAway Contact Gap FFB-LFB V or mA-> % Release Dropaway/Pickup-> Contact Resistance of all contacts both Front and Back contacts.-> Operating Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while Operating @ above-> Release Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while release @ above-> Difference of Operate Time - Release Time.-> Bridging Test or Non Overlap Test.-> Transfer or Traverse Times while Operate and release.-> Operate Time @2nd Set Voltage or Current.-> Release Time @2nd Set Voltage or Current.-> Power Consumption @ Rated Voltage.-> Coil Current @ Rated Voltage at Room Temperature.-> Coil Resistance Corrected to 20deg C.-> Timing Waveform Graph for all active Contacts.

  • 8-CH Relay Output EtherCAT Module

    EPS-2308 - ADLINK Technology Inc.

    ADLINK" s EPS slave system features modular design for flexible high channel density, rugged construction, easy maintenance, and intelligent performance, compatible with 3rd party EtherCAT products. Precise time-deterministic control enables I/O synchronization for critical applications, and FPGA and ARM technology allow users to fully monitor status of EPS modules and systems, including operating temperature and usage cycle of relay switching, as well as motion control status for general purpose motor drive control. In addition, the ADLINK EtherCAT configurator enables auto-scan and configuration across EtherCAT systems. The EPS" unique structural and electronic design supports hot-swappable function, reducing repair time, and the rugged construction and operating temperature range of -20°C to 60°C allow operation in the harshest environments.

  • ARTES Automatic Relay Test Systems

    KoCoS Messtechnik AG

    The purpose of power system protection is to use accurate and reliable protection devices to detect faults promptly and without fail and to minimize impairments to the power supply by selectively switching off faulted sections of the system.The use of suitable protection devices can significantly improve the safety and reliability of complex electrical power systems and installations. Regular testing is the only way to ensure that these protection devices function correctly throughout their operational life.More than 20 years of experience in developing and manufacturing automatic relay test systems have gone into creating the third generation of ARTES test instruments. Back in 1996, KoCoS was the first company to present Windowsbased testing software for controlling and operating test equipment and the company continues to play a pioneering role in the design of clearly structured and ergonomic user interfaces today.

  • PXI-2520, 80-Channel, 2 A, SPST PXI Relay Module

    778572-20 - NI

    80-Channel, 2 A, SPST PXI Relay Module—The PXI‑2520 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2520 is fully software programmable, and it supports onboard relay count tracking. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for automated test equipment (ATE) loads or for controlling heaters, lights, and fans.

  • PXI-2522, 53-Channel, 2 A, SPDT PXI Relay Module

    778572-22 - NI

    53-Channel, 2 A, SPDT PXI Relay Module - The PXI‑2522 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2522 is fully software programmable, and it supports onboard relay count tracking. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for automated test equipment (ATE) loads or for controlling heaters, lights, and fans.

  • PXI-2523, 26-Channel, 2 A, DPDT PXI Relay Module

    778572-23 - NI

    26-Channel, 2 A, DPDT PXI Relay Module - The PXI‑2523 is a general-purpose switch module that features independent double‑pole double‑throw (DPDT) armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2523 is fully software programmable, and it supports onboard relay count tracking. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for automated test equipment (ATE) loads or for controlling heaters, lights, and fans.

  • PXI-2521, 40-Channel, 2 A, DPST PXI Relay Module

    778572-21 - NI

    40-Channel, 2 A, DPST PXI Relay Module—The PXI‑2521 is a general-purpose switch module that features independent double‑pole single‑throw (DPST) armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2521 is fully software programmable, and it supports onboard relay count tracking. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for automated test equipment (ATE) loads or for controlling heaters, lights, and fans.

  • PXI-2571, 66-Channel, 1 A, SPDT PXI Relay Module

    778572-71 - NI

    66-Channel, 1 A, SPDT PXI Relay Module—The PXI‑2571 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal.

  • PXI-2570 , 40-Channel, 1 A, SPDT PXI Relay Module

    778572-70 - NI

    40-Channel, 1 A, SPDT PXI Relay Module—The PXI‑2570 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Each relay channel has a normally closed (NC), normally open (NO), and common (COM) terminal.

Get Help