Showing results: 991 - 1005 of 4029 items found.
-
JX16/KC -
Cytec Corp.
This module has 16 single pole, Form C, discrete relays which are wired and controlled individually. The relays can be externally wired to make any configuration needed. Use as individual A-B relays or use them to drive external relays, solinoids, or any external device. It is available with Type S or M reed relays.
-
LXA/128-MF -
Cytec Corp.
These Chassis control up to 16 modules with up to 8 relays per module. A large variety of different switch modules are available to build almost any configuration. Modules are available to build matrix or mux configurations or discrete relay modules. Input detection modules, output driver modules and proto board modules allow custom systems for almost any application. LEDs on the front panel show switch and power status. A thumbwheel manual control is optional.
-
42-781A-021 -
Pickering Interfaces Ltd.
The 40-781A-021 (PXI) and 42-781A-021 (PXIe) are single failsafe SPDT 18 GHz microwave relay modules with internal terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Fairview Microwave Inc.
Waveguide Electromechanical Switch models cover C, X, Ku, K, Ka frequency bands up to 40 GHz. SPDT and Optional DPDT* Configurations with Latching Self Cut-Off Actuators, TTL Logic, and Position Indictors with manual override. Patented Motor Drive with Arc Suppression. Designs support WR-137, WR-112, WR-90, WR-75, WR-62, WR-42, and WR-28 waveguide sizes with O Rings for pressurized operation. Power handling capability up to 12 kW CW and 320 kW Peak. These waveguide electromechanical relay switches deliver desirable performance that includes high isolation levels up to 105 dB, and extremely low insertion loss down to 0.01 dB.
-
40-190C-212 -
Pickering Interfaces Ltd.
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
42-190C-212 -
Pickering Interfaces Ltd.
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190C-112 -
Pickering Interfaces Ltd.
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
42-190C-112 -
Pickering Interfaces Ltd.
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190C-012 -
Pickering Interfaces Ltd.
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
42-190C-012 -
Pickering Interfaces Ltd.
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
JX8/KCP -
Cytec Corp.
This module has 8 single pole, Form C, discrete power relays which are wired and controlled individually. The relays can be externally wired to make any configuration needed. Use as individual A-B relays or use them to drive external relays, solinoids, or any external device. Screw Terminal Connectors and Armature power relay for switching up to 8 Amps of DC or AC current.
-
YAVAL022 -
6TL Engineering
5x (1×4) Mux + 2x Pass trough Selftest function 30Vac/dc, 10W Max Max current 500mA Reflexive
-
779640-01 -
NI
The USB-6525 is an industrial, bus-powered USB I/O device that can automate even the most demanding applications. The solid-state relay outputs are ideal for controlling pumps, valves, motors, and various other industrial actuators. The USB-6525 features channel-to-channel isolated digital inputs that you can use to read from industrial digital sensors, and eight solid-state relay outputs featuring 60 VDC/30 Vrms switching voltage and 500 mA per channel maximum switching current. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators.
-
779313-01 -
NI
16-Channel, ±30 VDC, 8 Sink/Source Inputs, 8 Relay Outputs, Isolated PXI Digital I/O Module—The PXI‑6521 is an industrial digital I/O module with high channel isolation and industry-standard 24 V logic levels. For added safety, the PXI‑6521 requires a keyed connector. If a computer or application fault occurs, the PXI‑6521 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. It also features programmable power-up states, digital filtering, and change detection for optimal control over your application.
-
779312-01 -
NI
The PCI-6521 is an industrial digital I/O module with high channel isolation and industry-standard 24 V logic levels. If a computer or application fault occurs, the PCI-6521 can use … digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. It also features programmable power-up states, digital filtering, and change detection for optimal control over your application.