  • Three Phase Load Bank

    REOLOAD 310 - REO Ltd.

    A three phase load bank rated for 48kW, with fan cooling. The front panel layout includes a switch panel for configuring the separate resistor modules to give the required resistance and current range. There are also digital panel meters for displaying the phase voltages and currents. An interface for PLC control is also provided.

  • Handheld LPR Corrosion Data Logger

    MS1500L - Metal Samples Company

    The MS1500L is a hand-held, battery-powered, intrinsically safe corrosion meter capable of measuring and storing data from all types of 2- or 3-electrode linear polarization resistance (LPR) corrosion probes. The instrument is light weight, microprocessor-based, and features a simple, menu-driven interface using a 12-key keypad and a 4-line LCD display.

  • Economical Thermocouple Thermometer °C (Type K)

    874C - TEGAM Inc.

    Tegam''s 874F and 874C Budget Series thermometers provide the economical solution for general-purpose temperature measurement needs. The units accept type K thermocouples and probes. Constructed with ABS material for resistance to inorganic salts, alkalies, and many acids and exceptional durability, this meter is designed for the toolbox and for use in the field.

  • Bench Meters

    Fieldpiece Instruments, Inc

    A classic style multimeter with True RMS and phase rotation. This manual ranger covers the electrical parameters you need for HVACR and, with detachable test leads, works with our accessory heads to test non-electrical parameters too. The LT16A meter measures current, resistance, voltage, capacitance, frequency, continuity and more. Test leads store in the meter body along with the tilt stand and magnetic hanger. The body is constructed of durable ABS plastic and a blue backlight makes the large LCD even more visible.

  • Cable Length Meters

    PCE Instruments

    The cable length meters of PCE instruments provide various functions that can be useful in terms of measuring the length of cables or detecting cable breaks. Therefore the cable length meters function according to various measuring principles that will be described below. Using these devices enables determining cable lengths as well as the resistance and caliber of cables that are about to be laid or even already laid. Depending on the device that is being used, you can measure the length of cables to certain extends. Also the measuring ranges differ among the the devices.

  • Plate Rheometer

    DVNext Cone - Ametek Brookfield

    The DVNext Wells-Brookfield Cone/Plate Rheometer is a precise torque meter which is driven at discrete rotational speeds. The torque measuring system, which consists of a calibrated beryllium-copper spring connecting the drive mechanism to a rotating cone, senses the resistance to rotation caused by the presence of sample fluid between the cone and a stationary flat plate.

  • 1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester

    TH2521 - Shenzhen Chuangxin Instruments Co., Ltd.

    TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.

  • Clamp On Meters

    Triplett Test Equipment & Tools

    1000A True RMS AC/DC clamp-on meter with a backlit LCD display. It offers a large variety of measurement features including AC/DC Current, AC/DC Voltage, Resistance, Temperature, Capacitance, Continuity, Diode Test and NCV Detector. The rubberized overmolded housing provides impact and drop resistance in a sleek ergonomic design, and the user-friendly Auto Power Off feature helps maximizes battery life. With a CAT III 600V design, it provides superior resistance to damage from transient overvoltages in any demanding industrial setting. The Model 9325 is suited for a variety of industrial and residential applications such as security, electrical, HVAC installations and more. Includes test leads, Type K Temperature probe, 9V battery, and case.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL - Tenma

    The 72-7226 CAL from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL DU - Tenma

    The 72-7226 CAL DU from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL D - Tenma

    The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Guarded Heat Flow Meter

    Thermtest Instruments

    The Guarded Heat Flow Meter (GHFM-02) follows ASTM E1530-19 for testing thermal resistance and thermal conductivity of solids, such as metals, polymers and composites. The easy to operate GHFM-02 follows the trusted steady-state approach, with the addition of a guard to limit the effects of lateral heat loss. This design, allows testing of a wide range of materials with low to medium thermal conductivity.

  • High Resolution Precision Milliohm Meter (220VAC) - Benchtop Meter Provides Resolution Down to 0.01mΩ

    Extech 380562 - Extech Instruments Corporation

    Compact and precise, the Extech 380562 Milliohm Meter has 7 ranges and measures down to 0.01mΩ using 4-wire Kelvin clip test leads. Measurements are displayed on the unit's large 0.8", 1999-count LCD. Built-in comparator for Hi/Lo/Go resistance testing or selection. Complete with 4-wire cables with Kelvin clip connectors and power cord.

  • Low Noise Test Leads For N1413 With B2980 Series, 3m

    N1425B - Keysight Technologies

    The N1425B is designed to operate specifically with the B2985B/87B. It can hold DUTs with large terminals being used with the N1426C. The N1426A with the N1425B is available for measurements of small DUTs such as PC boards or IC sockets. The N1426B with the N1425B enables the construction of simple custom-made test leads. The N1413A High Resistance Meter Fixture Adapter is also required to connect the N1425B to the B2985B/87B.

  • Low Noise Test Leads For N1413 With B2980 Series, 1.5m

    N1425A - Keysight Technologies

    The N1425A is designed to operate specifically with the B2985B/87B. It can hold DUTs with large terminals being used with the N1426C. The N1426A with the N1425A is available for measurements of small DUTs such as PC boards or IC sockets. The N1426B with the N1425A enables the construction of simple custom-made test leads. The N1413A High Resistance Meter Fixture Adapter is also required to connect the N1425A to the B2985B/87B.