Showing results: 241 - 255 of 2640 items found.
-
6237 DLRO -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measure down to 1μΩ.● 6 ranges from 2.000mΩ to 200.0Ω.● Maximum resolution of 1μΩ.● Three test currents with over-temperature protection.● Four terminal measurement.● Protection against inadvertent connection to over- voltage. (crow bars for current and voltage)● Clear & large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave™ Inside.● EnerSave™ Auto-hold.● EnerSave™ Auto-off.● Rechargeable battery operated● Robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
-
WA 180 -
Wuhan Sangao Electrical Test Installations Limit Co.
WA180 Type Large earth resistance tester,To test substation earthing network(4Ω), Hydroelectric and Thermoelectric Power Plant,microwave(10Ω),lighting rod(10Ω)etc.Using new type variable frequency AC power supply, And adopts microcomputer control and signal processing measures, Solved the problem of interference of the testing process, To simplify the test procedure, To improve the precision and accuracy of the test results, reducing test personnel's the labor intensity and the cost of testing.The instrument can be used to test all kinds of power frequency earth resistance,contact voltage,step voltage etc frequency power parameters and soil resistivity. The instrument adopts the different frequency Anti-interference resistance technology, under strong interference environment accurately measured the frequency under 50Hz data.The maximum test current is 5A,it will not cause the earth device potential too high,and it also has strong anti interference ability, so it can be measured in the case of non power.
-
MRC ltd.
The UV Weather resistance test chamber is the world’s most widely used weathering tester to test types of damages include color change, gloss loss, chalking, cracking, crazing, hazing, blistering, strength loss and oxidation.
-
MSEI-200C -
MULTI MEASURING INSTRUMENTS Co., Ltd.
This model can measure insulation resistance of DC current circuit in PV systems (between PV module and power conditioner) on the live line and can distinguish the deteriorated part between Power Phase, Neutral Phase, P/N Phase and or PV modules.
-
9100-2 -
Palico Instrument Laboratories
The Model 9100-2 measures the resistance of single or multiple battery separators quickly and accurately when used with our Model 9000-9100 Electrolyte Test Bath. This system uses a 4-terminal measurement technique which cancels the effects of electrode/electrolyte potentials.
-
LRM-10 -
ndb Technologies Inc.
The LRM-10 is a 10A micro-ohmmeter kit designed to measure low resistance for electrical interconnections integrity testing. The LRM-10 has a range from 0.01µΩ to 200Ω. It comes with heavy duty four points probes and it is compatible with a great variety of optional accessories.
-
Fluke 1623-2 GEO -
Iconic Engineering Limited
Fluke 1623-2 GEO Earth Ground Resistance Meter Performs stateless earth ground rod testing (two clamps). One of the most important things about Fluke 1623-2 earth tester always provides accurate results in any environment.
-
8PK-ST1520 -
Prokit's Industries Co., Ltd.
Capable of measuring earth voltage (Vac.) 2mA measuring current permits earth resistance to test without tripping earth leakage current breakers in the circuit. Battery operated. Auto power off function. Data hold function. Small and light weight.
-
ASTM D1781 -
National Technical Systems
This test method is used to compare adhesion between flexible and rigid adherents, or between flexible facing of a sandwich structure and its core. Comparisons of adhesives and processes are only applicable when test specimens and conditions are the same. The peel resistance may indicate degree of cure for relatively brittle adhesives.
-
RMO TW Series -
Amperis sl
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
ST-1520 -
MRC ltd.
Capable of measuring earth voltage.2mA measuring current permits the testing of earth resistance without tripping earth leakage current circuit breakers in the circuit.Auto power off function.The timer operates automatically for approximately three to five minutes when the "push button switch" and "timer on button" are pressed together.
-
CRMS -
Ultra-Tech Enterprises, Inc.,
The CRMS is a system designed to allow any user to measure the resistance of each set of relay contacts associated with the relay under test. The test system consists of a CONTACT RESISTANCE MEASUREMENT UNIT (CRMU), a MULTIPLE RELAY TEST RACK, as well as an interconnect CABLE ASSEMBLY. Either DC or AC energy to pick and drop relay coils under test for all contact measurements is supplied from the CRMU and easily interfaces with the Multiple Relay Test Rack. For additional and more thorough testing of relays an external relay tester can be interfaced to the Multiple Relay Test Rack to supply energy to the relay coil. It is recommended that the UTE Relay Tester With Timer/Counter (UTE Product # 15967-00) be utilized so the operator can take full advantage of the unique features it offers
-
Metal Samples Company
The electrical resistance (ER) technique is an "on-line" method of monitoring the rate of corrosion and the extent of total metal loss for any metallic equipment or structure. The ER technique measures the effects of both the electrochemical and the mechanical components of corrosion such as erosion or cavitation. It is the only on-line, instrumented technique applicable to virtually all types of corrosive environments.
-
Metal Samples Company
Linear polarization resistance (rosion probes are commonly used in the water treating industry and other environments where instantaneous, on-line corrosion rate readings are required. Linear polarization probes are ideally suited to monitor fluctuations that may occur within a system; for example, these probes can be used to monitor corrosion inhibitor effects on a regular basis.
-
AMIC-5010 -
Amperis sl
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits