Showing results: 361 - 375 of 2640 items found.
-
-
-
B2987B -
Keysight Technologies
The B2987B Electrometer/High Resistance Meter is the world’s only graphical electrometer that allows you to confidently measure small currents with 0.01 fA (0.01 x 10-15 A) resolution and large resistances of up to 10 PΩ (10 x 1015 Ω). In addition, battery operation eliminates AC line noise from your critical measurements.
-
1120 ER -
Standard Electric Works Co., Ltd
● Waterproof: IP54● Capable of measuring earth resistance and earth voltage● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test● The test leads are supplied as standard accessories for simplified two-wire measuring system● 0Ω adjustment● Battery operated● Data hold function● Low battery indication
-
2720 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
-
1820 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
4120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
-
1105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
4105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
2105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
1805 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
2120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
2705 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
National Technical Systems
Surface Insulation Resistance (SIR), as defined by IPC, is the electrical resistance of an insulating material between a pair of contacts, conductors, or grounding devices that is determined under specified environmental and electrical conditions.In respect to the world of printed circuit boards (PCBs) and printed circuit assemblies (PCAs), SIR testing—also commonly referred to as Temperature Humidity Bias (THB) testing—is used to evaluate a product’s or a process’ ability to resist “failure” by means of current leakage or an electrical short (i.e., dendritic growth). SIR testing is typically performed under elevated temperature and humidity conditions—such as 85°C/85% RH and 40°C/90%—with periodic insulation resistance (IR) measurements obtained.
-
TWR-H Series -
IBEKO Power AB
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.