TESTEX Testing Equipment Systems Ltd.
Universal Wear Tester, to determine the wear and abrasion resistance of fabric used in clothing, footwear and industrials. This Wear Testing Machine complies with ASTM D3514/D3885/D3886, AATCC 119/120, FTMS 191/5300/5302, etc.
-
Micromatter
MICROMATTER Permacoat™ x-ray detector windows are beryllium based. The outer surface of the window has enhanced corrosion resistance due to a proprietary inert coating, which does not notably affect the transparency of the window.
-
TESTEX Testing Equipment Systems Ltd.
Schildknecht Flexing Tester is designed to determine the resistance of coated fabrics to damage by flexing due to oscillation at 500 times per minute. Schildknecht Flexing Tester complies with ISO 7854, BS 3424, etc.
-
TESTEX Testing Equipment Systems Ltd.
Schildknecht Flexing Tester is designed to determine the resistance of coated fabrics to damage by flexing due to oscillation at 500 times per minute. Schildknecht Flexing Tester complies with ISO 7854, BS 3424, etc.
-
DB23X Series -
Danbridge a/s
The Danbridge suite of instruments for precise measurement of capacitive, inductive and resistance parameters includes stand-alone measurement bridges for laboratory use as well as automatic systems for rapid measurement of a large number of components in industrial environments.
-
1kV Megohmmeter -
Greenlee Tools
*Calculations (automatic)*Potential Index and Dielectric Absorption Ratios*Tests Continuity, Resistance and Frequency Measurements*Programmable Alarms*Insulation Test, Resistance, Continuity*Hazardous Voltage Alert (Icon) if voltage is >70 volts 5.) On Board Timer, +1/- 1 sec
-
Calibrated 1kV Megohmmeter -
Greenlee Tools
*Calculations (automatic)*Potential Index and Dielectric Absorption Ratios*Tests Continuity, Resistance and Frequency Measurements*Programmable Alarms*Insulation Test, Resistance, Continuity*Hazardous Voltage Alert (Icon) if voltage is >70 volts 5.) On Board Timer, +1/- 1 sec.
-
Triplett Test Equipment & Tools
compact digital multimeter with a backlit LCD display. It offers a large variety of measurement features including AC/DC Voltage, DC Current, Resistance, Continuity, Diode Test, Transistor hFE, and Temperature. The rubberized boot provides impact and drop resistance in a sleek ergonomic design, and the user-friendly Auto Power Off feature helps maximizes battery life. The Model 1101-B is well suited for a variety of commercial and residential applications such as security, home theater, electrical, HVAC installations and more. Includes test leads with alligator clips, Type K bead probe and battery (9V).
-
Powerohm Resistors, Inc.
The Powerohm Variable Braking Resistor Analyzer will determine what braking resistor ratings are required for your specific application. The Powerohm VBR is a portable test unit that provides selectable steps of resistance for analyzing your braking requirements for a wide range of drive horsepowers. Simply connect the VBR to your drive or braking module and let the application decide what braking resistor it needs. Once you determine the optimal resistance value for your drives peak performance, the VBR's digital readout will accurately display the true duty cycle as the application runs.
-
Kikusui Electronics Corp.
high performance electronic load is the successor to the highly respected PLZ-4W series, whilst still retaining the same high specification and build quality. Advances include a high visibility color display, low voltage operation from a minimum of 1 V to a maximum of 150 V. Programmable profiles of voltage/current can be applied (using the new ARB function, as used in LED/solar testing) in addition to the inherited 6 modes of operation: Constant Current, Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Resistance + Constant Voltage.
-
Neutronics Manufacturing Co.
Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester, and uses a test current of 100A DC, resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new, fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100
-
Greenlee Tools
Low voltage testing is able to catch errors such as shorts and opens by applying current to a wire and measuring the voltage. The wire will have a current affected by several factors including resistance and components. If the wire is connected correctly, the test will read low resistance. That means current is flowing through the wire as expected and reaching the required connections. If the tester reads high resistance it means something is impeding the current from reaching its destination. This could be caused by a number of causes.
-
CTT -
ndb Technologies Inc.
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
MUX-R -
Raytech AG
Raytech Multiplexer MUX R is designed to drastically reduce cabling time and increase test performance. It is made to be used with Raytech Winding Resistance and Turns Ratio Meters. Any MUX R configuration can be easily controlled by a Winding Resistance Meter touch panel or by remote.
-
PAT-815 -
Sonel S.A.
TECHNICAL SPECIFICATIONFILESPAT-815 digital meter is used to measure the parameters of electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power, automatic measurement of all RCD parameters.