Showing results: 1216 - 1230 of 2640 items found.
-
PowerCheck 1557 -
Seaward Electronic Ltd
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
PZ-V/M Series -
Keyence
Automatic Calibration Photoelectric Sensors. Detections are unaffected by variations in target color or angle. Excellent resistance to dust and dirt. One touch, fully automatic calibration. Unaffected by highly reflective target backgrounds. 40 model variations available including quick disconnect types. High-power red LED(Except for PZ-M71/V71)
-
Teledyne Marine Cable Solutions
A wide range of coiled and straight cable for power, control, and video combinations suited for portable and fixed towers. Telescoping and retractable coiled cords optimize space and allow for ease of handling. Cables are manufactured using a specially formulated polyurethane called Telethane®, which offers superior abrasion resistance and excellent flexibility.
-
PRF-912B -
Prostat Corporation
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
PRS-801-WV -
Prostat Corporation
- Ideal when qualifying or cerftifying material & installation- Each electrode has a resistance of less than 10 ohms- Flatness is measured and delivered within Prostat's specs- Capped to protect the pad against deformation- In accordance with ANSI/ESD S4.1 amd ANSI/ESD S7.1- NIST traceable ceritificate provided for each premium electrode
-
1394A -
Ballentine Laboratories, Inc.
Nominal Heater Current: 5 mA rms,Max. Heater Current: 7.5 mA rmsCouple Output: 7 mV ± 12% at nominal heater current.Couple Resistance: 8 W ± 20%.Maximum DC Reversal Error: ± 0.04%Couple Output Voltage to Heater (ground): ± 50 V (dc + acpk-pk) max.
-
TR1 -
North Atlantic Industries
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
PRF-911PT -
Prostat Corporation
The PRF-911 Concentric Ring is to be attached to the PRS-801B Resistance System included in this Packaging Test Kit. This system will also give you surface resistivity by multiplying the surface resistance measurement in ohms by 10 to obtain surface resistivity in ohms/square. The PRF-911PT meets requirements from ANSI/ESD STM11.11, ANSI/ESD STM11.12 snd IEC 61340-2-3. It will also approximate surface and volume resistivity measurements per ASTM D-257.
-
Fluke 1625-2 GEO -
Iconic Engineering Limited
The Fluke 1625-2 earth ground tester measures earth mishap resistances victimization solely clamps, solely stakes, or one clamp and stakes. With the stakeless check methodology, the Fluke 1625-2 is in a position to live earth mishap resistances for multi-grounded systems victimization solely current clamps. this method eliminates the harmful, and time intense job of disconnecting parallel grounds, and finding appropriate locations for auxiliary ground stakes.
-
HH2102A -
Colluck Company Limited
Basic Accuracy 1.0%. Jumbo LCD display 2000 count, 21mm figure height. Manual Ranging at your choice (19 Range). Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Signal injection and Diode test
-
HH2202 -
Colluck Company Limited
High Accuracy (Basic Accuracy 1.0%). Jumbo LCD display 4000 count, 21mm figure height. Convenient Auto Ranging. Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 40MΩ. Diode test, audible continuity check
-
AMETEK Sensors, Test & Calibration
Our multifunction process calibrators read and source RTD, thermocouple, current, voltage, frequency, and resistance to calibrate or verify your process sensors. They can also be combined with APM CPF pressure modules to calibrate pressure, or a dry-block to calibrate temperature. The ASC-400 features a large full color display with an advanced simplicity, easy-to-use interface.
-
UI-FT62 -
Unuo Instruments
Rubber Aging Oven, which is also named as Aging Oven, is used to test accelerated aging process in oven. It is mainly used to know materials change before and after aging oven test (heat resistance test). Unuo Instruments is rubber aging oven manufacturers and provide aging oven tester in affordable price.
-
Virginia Panel Corporation
TriPaddle Signal contacts carry up to 7 amperes (22 AWG wire) or 10 amperes (14 AWG wire) continuous and can carry pulsed current up to 15 amperes at a maximum duration of 800 milliseconds. Resistance ranges from .002-.004 OHMS. Superior performance is achieved by VPC's patented Tri-Paddle design.
-
ASM-BF/1 | VP 230043 -
Maschinenbau Haldenwang GmbH & Co. KG.
The ASM-BF/1 roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97.