Showing results: 1366 - 1380 of 2640 items found.
-
AM-360TRN -
Ketai instrument (kunshan) Ltd.
7 Function 20 range DC voltage can be measured 0~1000V AC voltage can be measured 0~1000V DC current can be measured 0~10A buzzer, on-off resistance can be measured 0~20MΩ battery measurement transistor measurement db measurement input impedance 20KΩ/ DVC 9KΩ/ACV Accessories include: battery 1.5Vx1, meter pen, manual, color box
-
Anatek Instruments
This is the fully-assembled, cablibrated and tested Blue ESR/Low Ohms Meter The latest and best Bob Parker design and successor to the famous Dick Smith ESR/Low Ohms Meter. This handy and affordable meter measures capacitor equivalent series resistance (ESR) in the circuit. ESR is a very important characteristic of capacitors greater than 1 ufd. This meter makes measurements which are often impossible to check with capacitance meters.
-
National Technical Systems
Compression testing is a very common testing method that is used to establish the compressive force or crush resistance of a material and the ability of the material to recover after a specified compressive force is applied and even held over a defined period of time. Compression tests are used to determine the material behavior under a load. The maximum stress a material can sustain over a period under a load (constant or progressive) is determined.
-
Aero Nav Laboratories, Inc.
The purpose of this test is to determine the resistance of materials and protective coatings to corrosive atmospheres when a more corrosive environment than the salt fog/spray test is required. The test is used when material is stored or operated in areas, for example, where acidic atmospheres exist, such as in industrial areas or near the exhausts of any fuel-burning device. Gases such as sulfur dioxide are used to replicate the exhausts of fuel burning devices.
-
Extech MN30 -
Extech Instruments Corporation
Easy-to-use smart pocket multimeter with AutoSensing feature enables the meter to recognize the input and automatically switch to the correct mode of operation (i.e. Voltage to Resistance measurement). True RMS AC Voltage measurement allows for accurate readings regardless of waveforms. Built-in Non-Contact Voltage (NCV) Detector allows for quick detection of live voltage. Convenient LED flashlight illuminates dimly lit area.
-
Chroma Systems Solutions, Inc.
The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.
-
TF346 -
TESTEX Testing Equipment Systems Ltd.
Glow Wire Tester, to determine the resistance to fire insulating parts. The testing of electro-technical products for fire hazard is conducted by simulating as closely as possible actual effects occurring in practice. Parts of electro-technical equipment which may be exposed to thermal stress due to electric effects & deterioration of which may impair safety of equipment shall not be unduly affected by heat & fire generated within the equipment.
-
LC Series -
Battery Metric
The LC Series machines are low current, low power devices configured for management of low capacity batteries. These devices offer very high input resistance and have current control as low a 0.25 micro Ampere. These machines also offer 3 current ranges. Select the device that has the current ranges required for the intended application. Other voltage and current configurations are also available.
-
CMM-40 -
Sonel S.A.
Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.
-
Model 717 -
Magnetic Instrumentation Inc.
The Model 717 Franklin Tester provides a means of testing single strips or punchings of flat rolled electrical steel, for surface insulation resistance under predetermined conditions of voltage and pressure.
-
TH2689 -
Changzhou Tonghui Electronic Co., Ltd.
TH2689/TH2689A is a rapid and precise capacitance leakage current insulation resistance tester. The max. test speed of 18 times/second, good performance and the suitable price provide the user an optimal choice.
-
AP2019 -
ZETLAB Company
*Can be used as shock sensors in equipment diagnostic systems;*Combination of high axial sensibility, intrinsic frequency and shock resistance;*Low sensitivity to electromagnetic fields;*Low intrinsic noise level.
-
Rishabh Instruments Pvt. Ltd.,
Rishabh Insulation Tester is a Digital Insulation Tester with selectable test voltage up to 10kV and Insulation. Resistance measurement upto 20 TΩ. Ideal for testing insulation in live switchyards.
-
M191 -
MEATEST, s.r.o.
High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.
-
IBEKO Power AB
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.