Showing results: 331 - 345 of 393 items found.
-
National Technical Systems
Fourier Transform Infrared Spectroscopy (FTIR) is a standard technique used in the identification of contaminating materials on the surface of printed circuit boards (PCBs) and around the leads of electronic components (BGA, capacitors, resistors, inductors, connectors, diodes, oscillators, transformers, IC, etc.) on printed circuit assemblies (PCAs). Additionally, FTIR can be used for “simpler” identifications, such as determining a specific type of plastic or rubber compound.
-
Protek Devices
ProTek's patented* Flip Chip TVS Arrays are designed for small circuit board applications with limited size and space availability. To reduce installation costs, the Flip Chip can be mounted directly onto the printed circuit board; similar to chip resistors and capacitors. These devices are ideal for use in portable electronics such as Cellular Phones, Cellular Phone Accessories, Personal Digital Assistants (PDAs), Laptops and Pagers.
-
CAT Advanced Series -
Amperis sl
Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:
-
AMETEK VTI Instruments
The AMETEK VTI Instruments EMX-7000 Series PXIe Precision Programmable Resistor Ladder modules provide four independent channels of programmable resistors. The EMX-7004 is capable of delivering exceptional stability and accuracy for any resistance value between 1 Ω to 16,383 Ω and can be adjusted in 1 Ω increments through the software application programming interface (API) or dynamic soft front panel.The EMX-7005, EMX-7006 and EMX-7007 are perfect for applications requiring higher resistance values, with programmable settings ranging from 163 kΩ to 16.383 Mohms, while the EMX-7014, 7015 and 7016 are ideal for general purpose applications not requiring ultra high accuracies.
-
ITS-90 -
Fluke Calibration
The defining instruments of the ITS-90 (International Temperature Scale of 1990) are Standard Platinum Resistance Thermometers (SPRTs) and ITS-90 fixed-point cells. SPRTs are calibrated in fixed-point cells to provide the highest possible temperature accuracy. Primary standards offered by Fluke Calibration include: long-stem SPRTs; capsule SPRTs; triple point of water cells; metal fixed-point cells; maintenance baths and maintenance furnaces for fixed-point cells; standard resistors.
-
National Technical Systems
The use of Scanning Electron Microscopy / Energy Dispersive X-Ray Spectroscopy (SEM/EDS) in the analysis of failure related issues of printed circuit boards (PCBs), assemblies (PCAs), and electronic components (BGA, capacitors, resistors, inductors, connectors, diodes, oscillators, transformers, IC, etc.) is a well-established and accepted protocol. As opposed to or simply in addition to normal optical microscopy, SEM/EDS allows for the “inspection” of areas of interest in a much more informative way.
-
MIG0603CAP -
EMC Partner AG
The MIG0603CAP consists of two circuits with impulse capacitance 20 µF and 0,25 µF. Both circuits generate a voltage wave shape 1,2/50 µs and are combined in a 4 unit height 19" rack. The generator circuits are defined in IEC 60384-14 and EN 132400. The serial resistors Rs, the impulse capacitor CT, and the load capacitance Cp will be automatically switched when different capacitance ranges are selected on the MIG0603CAP.
-
777598-01 -
NI
96-Channel, 5 V TTL/CMOS, 2.5 mA PXI Digital I/O Module—The PXI‑6508 uses four, 24‑bit programmable peripheral interfaces (PPIs) that can each be divided into three, 8‑bit ports. The PXI‑6508 can interface to peripherals or other computers, and it can operate in either a unidirectional or bidirectional mode and handshake with peripheral equipment. The PXI‑6508 is well suited for applications that require onboard pull-up resistors.
-
USB-1901/1902/1903 -
ADLINK Technology Inc.
The ADLINK USB-1900 series provides a range of USB 2.0-based multi-functional DAQ modules. The USB-1901 and USB-1902 16-bit 250 kS/s USB 2.0-based high-performance DAQ modules allow four different voltage input ranges, while the USB-1903 features additional built-in precision current-tovoltage resistors capable of direct measurement of current signal from 0 to 20 mA. The USB-1900 series is USB bus powered and equipped with removable screw-down terminals for easy device connectivity. The attached multi-functional stand can be used for desktop, rail, or wall mounting. Suitable for mixed-signal tests, laboratory research, and factory automation, the USB-1900 series provide a simple measurement solution at an affordable price.
-
Bender Inc.
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
G5.SAS -
Regatron AG
The G5.SAS series are unidirectional sources. It was developed specifically for testing inverters and simulating solar arrays and is suitable for use in laboratories and on test benches. The modular and finely graded G5.SAS series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The power supplies feature especially low capacitance values in the output filter stage and switchable earth leakage resistors for adaptation to the insulation measurement of the DUT.
-
Signatone Corp.
Sheet resistance mapping of thin films with a collinear 4-point probe, Temperature co-efficient of resistance (TCR) of thin films with collinear 4-point probe, Precision temperature co-efficient of resistance (TCR) with 2-point Kelvin probes and precision surface temperature probe, resistor testing with 2-point Kelvin probes,Precision resistor testing with a Kelvin probe card, temperature co-efficient of resistance resistor test (TCR), and Standard TCR test of multiple resistors with Kelvin probes or a probe card.
-
M143 -
Clarke-Hess Communications Research
The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.
-
Smiths Interconnect
Diamond is the best thermal conductor on earth. Combined with a low dielectric constant, it is an excellent RF dielectric material for high-frequency applications in which thermal performance is equally critical. By applying cutting-edge thin film process and extensive millimeter wave design experience, Smiths Interconnect has created a high-performance line of resistive components. The resulting products, our Diamond RF Resistives® resistors, terminations, and attenuators, are significantly reduced in size and unparalleled in average and peak power handling.
-
IRHF -
RARA Electronics Corporation
Precision Metal Clad Resistors designed in four- terminal technique, are distinguished by high load capacity as well as excellent accuracy. Isolated voltage and current connections making them suitable for very precise current measurements. Easy current measurement is performed by attaching to current bus directly and connecting to voltage (ampere) metal through flexible wires. The ULH models are UL approved versions. Units have a low inductance, heavy copper terminals. The main application is battery manufacturing test jig.