Filter Results By:

Products

Applications

Manufacturers

Showing results: 1591 - 1605 of 1862 items found.

  • Insulation & Multifunction Tester (OLED Display)

    1152 MF-M - Standard Electric Works Co., Ltd

    ● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ratio (DAR).● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1152 MF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (OLED Display)

    1155 TMF-M - Standard Electric Works Co., Ltd

    ● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ratio (DAR).● BS 16 edition.

  • Test Leads

    AL-34WB - Standard Electric Works Co., Ltd

    ● Wire length: 1.2m approx.    Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm   Outside diameter of  PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Insulation & Multifunction Tester (LCD Display)

    1151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1155 TMF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-01 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-02 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-01 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • Vehicle Inspect Lines Software System

    Foshan Analytical Instrument Co, Ltd.

    Flexible control mode(A collective-type control mode can be adopted,but a distributive-type control can also be adopted); Powerful system function(Distributive-type control and collective-type management,provide the functions of equipment debugging,vehicle log-in,vehicle testing and bill printing.A secret code and right-limit can be set so that the system safety function is enhanced); Remote control(A remote log-in,main remote control and remote printing can be realized in accordance with the actual conditions of the testing station.At the sametime,provides a powerful data-base and one station with multi-wire:That is one testing station has more

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    780180-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-02 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

Get Help