SC924 -
Frothingham Electronics Corporation
The SC924 is an electromechanical device for testing diodes loaded on burn-in boards.A set of Kelvin contacts is indexed from diode to diode. The contacts move over a range of 24 inches in the X direction and the table holding the boards moves over a range of 9 inches. This allows scanning of multiple burn-in boards or boards with multiple rows of diodes.
-
mks Ophir
This scanning slit M² measurement system accurately analyzes lasers with wavelengths from UV to Far Infrared with its silicon, germanium, or pyroelectric head. It features a compact portable design, immediate results, ISO compliant measurements, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of lasers of most wavelengths.
-
Rigol Technologies Inc.
Flexible, modular Data Acquisition system with high performance scanning 6.5 digit DMM. 5 slot mainframes and modules for customized data acquisition solutions including temperature, resistance, current and voltage measurements
-
Pacific Testing Laboratories
A partial list of our state of the art test equipment, applicable to these testing disciplines, will include the following: Two Scanning Electron Microscopes with EDS (SEM/EDS) Three Differential Scanning Calorimeters (DSC) Three Thermogravimetric Analyzers (TGA) Three Thermo Mechanical Analyzers (TMA) One Dynamic Mechanical Analyzer (DMA) Two Real-Time Fluoroscopic X-ray Systems, including a Microfocus System One Fourier Transform Infrared Microscope (FTIR) (capable of identifying a single particle of an unknown material) Two Ion Chromatographs (IC) (capable of identifying ionic impurities in ppm)
-
ERS -
Laplace Instruments Ltd.
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
LR -
Lectrosonics, Inc.
Excellent performance in a small package for ENG and DSLR video production is the purpose and intent of the LR receiver design. Tracking front-end filters block interference from high powered RF signals on nearby channels to preserve the extended operating range. RF spectrum scanning displays accurate results on the LCD to make finding clear spectrum quick and easy.
-
ioLight Ltd.
*Veterinary Worm Egg Counting*Counting of algae and other samples*Easy positioning of the sample*Methodically scanning of slides and counting chambers*Works with standard microscope slides and counting chambers (25x75mm or 1”x2”) and with 32mm wide counting chambers*Allows manual movement of the slide and counting chamber independently in the left-right (X) axis and front-back (Y) axis
-
Laplace Instruments Ltd.
These Pre-Selectors are high specification, switched band filters which track the scanning of the EMC Analyser. Control is via USB link from the Laplace EMCEngineer software supplied with SA1002 and SA3000 analysers. Installation and operation is completely automatic, and the filters will synchronise with the analyser scan without any operator intervention. A front panel switch allows manual operation if required.
-
Spec 64 -
Anfatec Instruments AG
The fiber coupled high speed Raman spectrometer is optimized for maximum light throughput and high speed spectrum acquisition. Connected to an AFM or a scanning stage, high speed Raman imaging is possible due to an integration time down to 10 ms per spectrum. The spectrometer can be operated with a separate software as stand-alone device or synchronized via the Anfatec AFM software.
-
Arrival 3D, Inc.
The term “reverse engineering” can be a little confusing. It is sometimes used for things like software and electronic circuits. When 3D scanning companies use the term, they are referring to the process of re-creating design drawings by taking measurements and/or scans of the part itself. It is a 2-step process: 1) capture a 3D scan of the object, and 2) Create a 3D CAD model of the object
-
Anfatec Instruments AG
*Golden (chemically resistive) vibration isolated STM body with implemented preamplifier*Computer with PCI board based SPM controller *Anfatec Scan & Anfatec Present*19“ STM controller (extra low noise 24 bit converters)*HV display for z-direction*High voltage amplifiers for the x-y-tube scanning*Optional: PC controlled bi-potentiostat and electrochemical cell
-
NaioSTM -
Nanosurf
The first scanning tunneling microscope (STM) was developed in 1981 by Gerd Binnig and Heinrich Rohrer at the IBM Research Laboratory in Rüschlikon, Switzerland, for the first time making individual atoms directly visible to a small group of specialists. They were awarded the Nobel Prize in physics in 1986. In 1997, Nanosurf went one step further and brought single atoms to the classroom!
-
AFM Heron -
Del Mar Photonics, Inc.
New, fully motorized AFM HERON (HERO of Nanotechnology) which allows to perfectly align a cantilever, laser and photodiode by just one click on a command button. The scanning settings and landing parameters are also automated that allows to avoid any time consuming adjustment operations, thus leaving more time to researcher for designing the experiment and performing more accurate measurements.
-
RangeVision cis
RangeVision ScanCenter software is designed to perform 3D scanning and post-processing of the obtained data. Our software is not divided into editions. We do not cut its functionality. All the updates and features are available regardless of the model of 3D scanner from RangeVision. Our developers use only unique algorithms of digitizing and post-processing of the obtained data when creating our software.
-
3077A -
TSI Inc.
Aerosol Neutralizer 3077A has five times the activity of the Model 3077. The 3077A is offered for general-purpose applications involving highly charged aerosols and low flow rates. It is supplied with our Model 3034 Scanning Mobility Particle Sizer™ (SMPS) spectrometer.Features and Benefits Radioactivity of 370 MBq Maximum flow rate of 5 L/min Kr-85 source