Shunts

An Instrument Shunt is a resistor connected in parallel with a measuring device to move the current range beyond a particular value for which the instrument is capable of measuring directly.

See Also: Current Shunts


Showing results: 76 - 90 of 135 items found.

  • Capacitance Bridge

    1621 - IET Labs

    The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.

  • Current Sensors

    Measurlogic

    Measurlogic offers an array of current sensors for every need, including split core, solid core and Rope current transformers (CTs); DC Shunts and Hall Effect Sensors. All of our electrical sensors are designed with an easy, un-intrusive installation in mind. With a low cost and high accuracy guarantee, we provide top of the line solutions for measurement and cost savings for residents and business owners alike.

  • Current Probes

    Teledyne LeCroy

    Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.

  • Voltage Logger

    Ajinkya Electronic Systems

    Besides from physical parameters; application also demands logging of voltages and currents. The IM2000 series Voltage Logger / Current Logger / Power Logger offered by us can accept DC shunt inputs, signals from convertors 4-20mA range or CT current inputs for higher AC currents or AC signals from PT. These can calculate values from the recorded channels to generate additional channel values.

  • Microprocessor Based Indicator

    Brighton Electronics

    Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available

  • DC Electronic Loads

    Keysight Technologies

    Keysight DC electronic loads provide you with the flexibility to test a wide range of applications from power-supply test to simulation of high-intensity discharge (HID) headlamps. The 16-bit voltage, current and power-measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.

  • Data Acquisition Recorders & Loggers

    DAS1800 - B&K Precision Corporation

    The DAS1800 can be configured for a wide variety of applications with slots for 10 input modules each supporting 4 or 8 measurement channels. Acquire data from any sensor with a voltage or current output (with shunt), or directly measure voltage, resistance, or temperature using thermocouples or resistance temperature detectors (RTDs).

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2A - Transducer Techniques, Inc

    The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • High Frequency Clock Divider Board

    Alliance Support Partners, Inc.

    Clock Divider is designed to divide high frequency signals, up to 2.5GHz, from 4 to 256 times. It will accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms. The clock division is controlled by 4 shunt jumpers. The circuit can be disabled and the divide by counter reset with 2 control signals. The on board regulator will accept voltages from 4.85 to 15.0V. The output is capable of driving 700mV Peak to Peak into 50 Ohms.

  • High Current Calibrator

    MC151 - Powertek LLC

    MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2 - Transducer Techniques, Inc

    The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • Multi-Channel Digital Power Meters

    66203/66204 - Chroma Systems Solutions, Inc.

    Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders

  • Ungrouped

    Weshine Electric Manufacturing Co., Ltd

    The instrument can measure single capacitor of single phase or three-phase shunt capacitor bank without removing wires.2. The instrument has the functions of inductance, resistance and current measurement.3. The instrument has two power supply modes: External AC220 V and built-in lithium battery meet various application scenarios.

  • Capacitance Bridge

    Guildline Instruments Ltd

    Capacitance Bridge is an instrument employing the AC Current Comparator principle. The 9910A is a versatile instrument for a wide range of applications including capacitance measurements, cable testing, corona loss measurements, insulator and dielectric testing, inductance measurements, potential transformer error measurements, shunt reactor loss measurements and power transformer testing.

  • DC Energy Meter

    Elmeasure India Pvt. Ltd

    Multiple channels can be measured by a single meter, EN2450N & EN2450DDifferential current input for all the current channelsProgrammable shunt secondary 50mV to 100mVProgrammable CT Primary for all channels up to 200A - for Hall Effect CTData logging for parameters such as Energy, Load hours and Ampere hoursEasy installation,Compact size, weight and simple wiring