Showing results: 3886 - 3900 of 8242 items found.
-
AOIP
Portable multifunction calibrator CALYS. Resulting from a close collaboration with industries, CALYS 50 integrates all the functions needed to control and maintenance of the process. Suitable for use in laboratory and on site, it is able to measure and transmit simultaneously on 2 isolated channels, different types of voltage signals, current, frequency, resistance and thermocouples and RTDs.Get a Quote Download datasheet
-
ATS310 -
AlazarTech
ATS310 is the best 20 MS/s 12 bit PCI Digitizer available. With its high signal to noise ratio and robust front-end circuitry, ATS310 has become a de-facto standard for motor testing applications. ATS310 has also been used for multi-channel transient recording applications, as it provides one of the lowest cost-per-channel in the industry.
-
SimMNSA -
Spirent Federal Systems
The M-code signal is part of the security architecture that all new Military GPS User Equipment (MGUE) has been required to use since 2017. Until recently, testing with non-classified AES-encryption and replay of M-code Satellite Data Sets (SDS) have been the only methods authorized for GPS M-code receiver testing using a constellation simulator.
-
KINGSINE Electric Automation Co., Ltd.
Universal Relay Test ApplicationsComplied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc100/1000Mbit Fiber port for SMV and GOOSE simulations6x35A & 4x310V independent high burden output channels13 channels independent low-level signal outputsAC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)Transducer calibration (0.02 class)
-
Insight Product Company
Insight Product Company offers a high-power synthesizer of pulsed signals. They are ideal for ESR, EPR, and DNP experiments. The synthesizer has a high frequency stability (10-6), and allows control over the duraction and begining time of pulses. The synthesizer also enables phase manipulation, where each pulse is shifted by 90 or 180 degrees relative to the previous pulse.
-
Analog Devices Inc.
Analog Devices' broad range of precision amplifiers provides industry-leading support to designers in need of traditional trimmed and zero-drift amplifier technology. Our precision amplifier family helps preserve the accuracy of dc information in an incoming signal with low offset voltage (VOS < 1 mV) and low temperature drift characteristics (TCVOS < 2 V/C).
-
Autronic S.r.l.
The ECU is designed to exploit the chemical-physical characteristics of the gas fuel used in Otto engines while maintaining the level of emissions of the exhaust gas according to the original standard car.The connector used in Air 48 is automotive type 48- Poles . The connection to the engine signals , offers exceptional qualities of connective security and protection against water infiltration .
-
327/328 -
Sensoray Co., Inc
Model 327 and 328 are bus-to-bus adapters that allow operating a PCI board from a PC/104+ card stack. They allow selection of important PC/104+ signals using jumper plugs, thereby avoiding the requirement of using hardwired settings. Model 327 aligns the PCI board parallel to the PC/104+ boards, while model 328 places it perpendicular.
-
Pickering Interfaces Ltd.
We manufacture LXI Wired Trigger Bus adaptors and accessories. These adaptors and accessories are designed to help debug a WTB system or provide conversion of signals to or from the WTB to products that do not support the WTB. LXI approved WTB cable assemblies and terminators are available to interconnect LXI devices that support the LXI Wired Trigger Bus extended function.
-
40-837-001 -
Pickering Interfaces Ltd.
The 40-837-001 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-101 -
Pickering Interfaces Ltd.
The 40-837-101 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-002 -
Pickering Interfaces Ltd.
The 40-837-002 is a 75Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-102 -
Pickering Interfaces Ltd.
The 40-837 is a 75 2x2 RF matrix available with 1 or 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
PFA-2 -
Precision Filters, Inc.
he PFA-2 is a compact, rugged, and versatile dual-channel precision filter/amplifier. The low-noise, high common-mode rejection balanced differential input with programmable AC/DC input coupling is ideal for conditioning static or dynamic signal inputs. Sharp, programmable 6-pole low-pass precision filters support two response characteristics which are optimized for making time-domain or frequency-domain measurements.
-
2100R Series -
Advanced Telemetrics International
Offers more performance and features while providing solutions to common shaft mounted obstacles. Separate but simultaneous data and status signals allow a variety of control functions independent of the high quality data stream ATi is known for. Battery power means lower noise floors, more versatile installations, no active power generation or tuning.