Filter Results By:

Products

Applications

Manufacturers

Signal

detectable impulse of electromagnetic radiation or quantum state superposed.

See Also: Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Conditioning, Signal Generators, Signal Meters, Signal Conditioners, Fidelity, Hunting


Showing results: 5386 - 5400 of 8184 items found.

  • Portable PD Monitoring of Medium and High Voltage Power Equipment with UHF, AE, and HFCT

    PDiagnosticM - Power Monitoring and Diagnostic Technology Ltd.

    The PDiagnosticM is a portable system that utilizes UHF, AE, and HFCT sensor modules to monitor PD signals from Medium and High Voltage power equipment.The system is ideal for monitoring critical power assets to find and monitor intermittent PD signals and to analyze the developing PD trends. The PD type is determined by automatic pattern recognition and internal defects can be found at an early stage.The system provides advanced protection with alarm functions and our Deep Learning data analysis capabilities utilizing our proprietary Intelligent Cloud Diagnostic Technology.

  • PXI Attenuator Modules

    Pickering Interfaces Ltd.

    Pickering's PXI Attenuator Modules are available in the following configurations:*Programmable RF Attenuators accurate DC to 3GHz programmable attenuator has a 1dB step resolution, allowing it to adjust signal amplitudes for optimum measurement by other devices.*Solid State Programmable RF Attenuators available in triple or hex formats with bandwidths between 10MHz and 6GHz.High Voltage *Attenuators provide a convenient way of attenuating high voltage low frequency signals to levels that can be captured by other PXI devices without risk of damaging them.

  • IRIG Time Code Receiver & Generator for Computers (PCI Express)

    TCR180PEX - Meinberg Funkuhren GmbH & Co. KG

    The TCR180PEX receives IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes and can be used for synchronizing the system time of its host PC. The IRIG output of this card can generate an IRIG signal for other IRIG time code readers. The output format is independent from the incoming IRIG signal - a perfect solution to your IRIG conversion requirements. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements) or as an IRIG converter device.

  • EMC Test Equipment

    TDEMI G series - Gauss Instruments

    TDEMI stands for a novel generation of EMI measurement systems providing real-time analysis and enabling the user to perform high-quality emission measurements in a fractional amount of time compared to conventional EMI receiver technology. Ultra-fast Analog-to-Digital Conversion as well as real-time signal processing allows to emulate the behavior of instruments like oscilloscopes, receivers and spectrum analyzers. Due to the TDEMI's powerful signal processing hardware platform, corresponding to a computation power of approx. 80 conventional. PCs, such measurements are extremely fast in comparison to state of the art solutions.

  • PCI Express Cable Extender

    SKU-016-XX - Amfeltec Corp.

    The PCI Express Cable Extender was designed to support the development and debugging of PCI Express boards. The PCI Express Cable Extender allows easy access from both sides of the PCI Express board that are plugged into the Extender. It has overcurrent protection and provides access to the PCI Express bus JTAG signals. By enabling access to the PCI Express bus JTAG signals, the PCI Express Cable Extender becomes a universal device that helps support the programming/loading of FPGA/CPLD during debugging and the verification PCI Express boards.

  • Scanning Electrochemical Systems

    Ametek Scientific Instruments

    The VersaSCAN is a single platform capable of providing spatial resolution to both electrochemical and materials-based measurements. Each VersaSCAN is based on a common high-resolution, long-travel, closed-loop positioning system mounted to a vibration-resistant optical base. Different auxiliary pieces are mounted to the positioning system. These ancillary pieces (e.g., an electrometer, piezo vibration unit, or a laser sensor) provide functionality to the positioning system for different scanning probe experiments. VersaSTAT potentiostats and Signal Recovery Lock-in Amplifiers are integrated via ethernet control to make accurate measurements of these small signals.

  • PXI Solid State Matrix Module, 6x2, 30 A

    40-554B-011 - Pickering Interfaces Ltd.

    The 40-554B-011 is a high current 6x2 matrix occupying two PXI chassis slots. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each matrix switching path can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid-State Matrix Module, 6x2, 10 A

    40-553A-011 - Pickering Interfaces Ltd.

    The 40-553A-011 is a high current 6x2 matrix occupying two slots of PXI chassis. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each matrix switching path can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • Frontend - Frequency Extension to D-Band (110 GHz to 175 GHz)

    FE170SR - Rohde & Schwarz GmbH & Co. KG

    The R&S®FE170SR is ideal for early sub-terahertz and 6G research activities. Once connected, the frequency range of the R&S®FSW signal and spectrum analyzer and the R&S®RTP oscilloscope are extended to the D band (110 GHz to 175 GHz), allowing engineers to access the range they need to develop the next generation of mobile communications. The easy-to-use, fully-calibrated solution is compatible with our signal generator, analyzer and oscilloscope environments. Plug it in and start designing the next generation of mobile communications today

  • PXI Ultra High Density 64x4 2-Pole Matrix

    40-533B-022 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.

  • PXI LIN Interface Module

    NI

    The PXI LIN Interface Module is a bus interface for developing applications with the NI-XNET driver. The NI-XNET device-driven DMA engine couples the LIN bus to host memory to minimize message latency. You can import, edit, and use signals from LIN Description File (LDF) databases in integrated LIN databases. PXI LIN Interface Modules work well for applications requiring real-time, high-speed manipulation of many LIN frames and signals, such as hardware-in-the-loop simulation, rapid control prototyping, bus monitoring, and automation control.

  • PXIe-2540, 350 MHz, 8x9 PXI RF Matrix Switch Module

    780587-40 - NI

    PXIe, 350 MHz, 8x9 PXI RF Matrix Switch Module—The PXIe‑2540 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXIe‑2540 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers.

  • BNC-2120, 68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block

    777960-01 - NI

    68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.

  • PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays

    M9120A - Keysight Technologies

    The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.

  • PNA-X Network Analyzers

    Keysight Technologies

    Keysight's PNA-X is more than just a vector network analyzer. It is the world’s most integrated and flexible microwave test engine for measuring amplifiers, mixers, frequency converters, and other active devices. The hardware includes two internal signal sources, a signal combiner, S-parameter and noise receivers, pulse modulators and generators, and a flexible set of switches and RF access points. These hardware features provide a powerful core for a broad range of linear and nonlinear measurements, all with a single set of connections to your device under test.

Get Help