  • Modulation Distortion Up To 70 GHz

    S930707B - Keysight Technologies

    S930707B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 70 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930707B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 8.5 GHz

    S930700B - Keysight Technologies

    S930700B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 8.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930700B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 26.5 GHz

    S930702B - Keysight Technologies

    S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 50 GHz

    S930705B - Keysight Technologies

    S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 90 GHz

    S930709B - Keysight Technologies

    S930709B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 90 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930709B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 13.5 GHz

    S930701B - Keysight Technologies

    S930701B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 13.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930701B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 125 GHz

    S930712B - Keysight Technologies

    S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 43.5 GHz

    S930704B - Keysight Technologies

    S930704B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 43.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To And Beyond 125 GHz

    S930713B - Keysight Technologies

    S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • USRP-2955, 10 MHz to 6 GHz, 80 MHz Bandwidth, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device

    785264-01 - NI

    The USRP-2955 provides an integrated hardware and software solution for rapidly prototyping high-performance wireless receiver systems. It is designed for over-the-air signal acquisition and analysis. It features a two-stage superheterodyne architecture with four independent receiver channels and shares local oscillators for phase-coherent operation. It also offers a Kintex-7 FPGA programmable with the LabVIEW FPGA Module. With these features, the USRP-2955 has the RF and processing performance for applications such as spectrum monitoring, direction finding, signals intelligence, wideband recording, and radar prototyping. The USRP-2955 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) Reference Clock, which improves frequency accuracy and synchronization.

  • USRP-2945, 10 MHz to 6 GHz, 80 MHz Bandwidth, Reconfigurable USRP Software Defined Radio Device

    785263-01 - NI

    10 MHz to 6 GHz, 80 MHz Bandwidth, Reconfigurable USRP Software Defined Radio Device - The USRP-2945 provides an integrated hardware and software solution for rapidly prototyping high-performance wireless receiver systems. This software defined radio reconfigurable device is designed for over-the-air signal acquisition and analysis. It features a two-stage superheterodyne architecture with four independent receiver channels and shares local oscillators for phase-coherent operation. It also offers a Kintex-7 FPGA programmable with the LabVIEW FPGA Module. With these features, the USRP-2945 has the RF and processing performance for applications including spectrum monitoring, direction finding, signals intelligence, wideband recording, and radar prototyping.

  • PXI-2555, 2.5 GHz, 75 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module

    778572-55 - NI

    2.5 GHz, 75 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module—The PXI‑2555 is an RF signal multiplexer switch module. The internal termination of the PXI‑2555, which helps prevent high-power reflections that arise from open channels on the module, makes it ideal for use in video RF applications where such reflections can damage the source. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PXI-2558, 2.5 GHz, 75 Ω, Quad SPDT PXI RF Relay Module

    778572-58 - NI

    2.5 GHz, 75 Ω, Quad SPDT PXI RF Relay Module - The PXI‑2558 is a general-purpose single‑pole double‑throw (SPDT) switch module. You can use it to add flexibility to your video switch network or to maintain uniform signal paths across multiple channels when building high‑channel‑count multiplexers. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PCI-8511, 1‑Port, Low‑Speed/Fault-Tolerant CAN Interface Device

    780682-01 - NI

    1‑ or 2-Port, Low‑Speed/Fault-Tolerant CAN Interface Device—The PCI‑8511 is a fault-tolerant controller area network (CAN) interface for developing applications with the NI‑XNET driver. The PCI‑8511 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex models and applications.

  • Data Acquisition Systems

    Scientech Technologies Pvt. Ltd.

    Data Acquisition Systems have its contribution in a wide range of activities of day-to-day life. Most commonly, it is used to measure the electrical signals from some sensor. These signals may represent the state of a physical process, such as the position and orientation of machine tools, the temperature of a furnace or the size and shape of a manufactured component. Data Acquisition Systems are widely used today in home automation systems, industrial monitoring and control as well as in a variety of other time-critical applications. Installation of Data Acquisition Solutions in Industries is a flexible and cost-effective measurement solutions. Today, Data Acquisition Systems along with "Internet of Things" have led to development of many applications.