Filter Results By:

Products

Applications

Manufacturers

Signal

detectable impulse of electromagnetic radiation or quantum state superposed.

See Also: Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Conditioning, Signal Generators, Signal Meters, Signal Conditioners, Fidelity, Hunting


Showing results: 6676 - 6690 of 8202 items found.

  • Automotive RF Design Verfication Test System

    LXinstruments GmbH

    The system is used for design verification of RF assemblies. By using similar measurement technology and test software as in the production testers, parts of the test procedures developed in development can be reused in production. The DUTs are tested in RF-tight shield boxes and contacted via original plugs. The shield boxes are connected via N-connectors and other typical laboratory contacts. This allows test setups to be easily modified and individual signal paths to be separated.

  • LXI Microwave Multiplexer, 50Ω 4-Channel 13-Bank 6GHz SMA

    60-802-013 - Pickering Interfaces Ltd.

    The 60-802-013 is a 4-channel, 13-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.

  • LXI Microwave Multiplexer, 50Ω 4-Channel 14-Bank 6GHz SMA

    60-802-014 - Pickering Interfaces Ltd.

    The 60-802-014 is a 4-channel, 14-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.

  • LXI Microwave Multiplexer, 50Ω 6-Channel 1-Bank 6GHz SMA

    60-801-001 - Pickering Interfaces Ltd.

    The 60-801-001 is a 6-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.

  • PXI-2575, 196‐Channel, 1-Wire PXI Multiplexer Switch Module

    778572-75 - NI

    196‐Channel, 1-Wire PXI Multiplexer Switch Module —The PXI‑2575 is a high‐density PXI multiplexer switch module that is ideal for high‑channel‑count automated test applications. It uses electromechanical relays and can route hundreds of signals to measurement devices or from source units. The PXI‑2575 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

  • PXIe-2575, 196‐Channel, 1-Wire PXI Multiplexer Switch Module

    780587-75 - NI

    196‐Channel, 1-Wire PXI Multiplexer Switch Module —The PXIe‑2575 is a high‐density PXI multiplexer switch module that is ideal for high‑channel‑count automated test applications. It uses electromechanical relays and can route hundreds of signals to measurement devices or from source units. The PXIe‑2575 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

  • FPGA PXI Digital I/O Card

    GX3500 - Marvin Test Solutions, Inc.

    The GX3500 is a user configurable 3U FPGA PXI card which offers 160 digital I/O signals for specific application needs, as well as providing pin for pin compatibility with NI PXI 7811R and 7813R FPGA cards. The card employs the Altera Cyclone III FPGA which can support clock rates up to 150 MHz and features over 55,000 logic elements and 2.34 Mb of memory.

  • LXI Microwave Multiplexer, 50Ω 6-Channel 2-Bank 6GHz SMA

    60-801-002 - Pickering Interfaces Ltd.

    The 60-801-002 is a 6-channel, 2-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.

  • LXI Microwave Multiplexer, 50Ω 6-Channel 10-Bank 6GHz SMA

    60-801-010 - Pickering Interfaces Ltd.

    The 60-801-010 is a 6-channel, 10-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.

  • Precision Capacitance Meter

    TH2638C - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638 - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638B - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638A - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Toxic Gas Sensor

    Model 100 - Teledyne Gas & Flame Detection

    Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

  • Shield Level / Pathloss Equipment

    SG1000B/PR1000A - Praxsym

    The SG1000 Signal Generator and PR1000A Preamplifier have been designed to simplify the measurement of shielding integrity in a shielded enclosure. When coupled with a high stability spectrum analyzer and an appropriate selection of test antennas, the SG1000/PR1000A combination can measure shielding effectiveness at all of the NSA 94-106 (supersedes NSA 65-6) defined test frequencies from 1 kHz to 10 GHz.The PR1000A amplifies the received signal from the test antenna and overcomes the high noise figure of the companion test receiver or spectrum analyzer. The PR1000A will ensure that the system noise figure will be less than 4.5 dB at all test frequencies from 1 kHz to 10 GHz. When used with a spectrum analyzer measurement bandwidth of 100 Hz, the system exhibits a sensitivity of -150 dBm at the test antenna output.​To overcome high cable loss between the test antenna and the PR1000A assembly at 10 GHz, a remote low noise pre-amplifier (Praxsym PN 310-010091-001) is mounted directly onto the 10 GHz antenna.

Get Help