Showing results: 106 - 120 of 167 items found.
-
40-551-001 -
Pickering Interfaces Ltd.
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, also available with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
40-551-003 -
Pickering Interfaces Ltd.
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
34903A -
Keysight Technologies
The Keysight 34903A is a general-purpose switch module for the 34970A/34972A Data Acquisition/Switch Unit. It has 20 independent single-pole, double-throw (SPDT) relays and is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. Combine it with matrix and multiplexer modules to build custom switch systems. Its 300 V, 1 A contacts can handle up to 50 W, enough for many power line switching applications.
-
NI Powertrain -
NI
NI Powertrain Controls systems incorporate the LabVIEW reconfigurable I/O (RIO) architecture to create some of the world’s most flexible and capable combustion analysis and engine control systems. The engine control systems can drive both solenoid and piezoelectric direct injectors, control timing events with 25 ns of precision, and implement novel engine control strategies such as next- and same-cycle control. The combustion analysis systems are available in both portable and higher performance stationary form factors.
-
GM1-HS -
Alpha Lab, Inc.
The Model GM1-HS measures the strength and polarity of magnetic fields up to 799.99 gauss. The thin sensor is at the end of a 100 cm flexible cable. The sensor tip is also flexible and can be bent for a variety of situations. The sensor can be held against the surface of a steel part to check for residual magnetism, or it can be bent into an "L" shape to measure inside a DC Solenoid. This meter has a resolution of .01 gauss (1/50 of the Earth's typical field) which is finer resolution than the Model GM1-ST. It is also used to map fields from large magnets (If fields are over 800 gauss, use the Model GM1-ST). The meter has immediate turn-on and updates 4 times a second. There is no setup required, making this the fastest gaussmeter available.
-
40-131-201 -
Pickering Interfaces Ltd.
These are low cost, general purpose electromechanical relay cards capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.
-
40-131-001 -
Pickering Interfaces Ltd.
These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.
-
40-157-001 -
Pickering Interfaces Ltd.
40-150/151 modules have 8xDPST or 12xDPST power relays, suitable for switching inductive/capacitive loads up to 5A at 250VAC. 40-155/156 modules have 8xSPDT or 16xSPDT power relays and 40-157 is configured as 8xDPDT. Power relay modules are intended for switching heavy AC or DC loads or for slave switching large external relays, contactors and solenoids. The 40-150 series of power relay module are suitable for applications requiring switching of either mains voltage or DC current.
-
40-550-902 -
Pickering Interfaces Ltd.
This version of the 8x4 power matrix is for heavy current/low duty cycle power switching. Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current.
-
779517-01 -
NI
60 V, 32-Channel (Sinking Output), 8 µs C Series Digital Module - The NI‑9477 works with industrial logic levels and signals to connect directly to a wide array of industrial relays, solenoids, and motors. Each channel is compatible with signals from 5 V to 60 V and … features isolation from channel‑to‑earth ground. You can wire the NI‑9477 channels in parallel to sink up to 20 A of current per module (1 A per channel maximum).
-
780174-01 -
NI
60 V, 32-Channel (Sinking Output), 8 µs C Series Digital Module - The NI‑9477 works with industrial logic levels and signals to connect directly to a wide array of industrial relays, solenoids, and motors. Each channel is compatible with signals from 5 V to 60 V and … features isolation from channel‑to‑earth ground. You can wire the NI‑9477 channels in parallel to sink up to 20 A of current per module (1 A per channel maximum).
-
34939A -
Keysight Technologies
The Keysight 34939A is a high density general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 64 independent single-pole, single-throw (SPST) relays that can switch 1A and carry 2A. This module can be used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The relays are 100V, 1A contacts and can handle up to 60W. Standard 78-pin Dsub connectors allow for use with standard cables, screw terminal blocks, or mass interconnect solutions.
-
40-549-001 -
Pickering Interfaces Ltd.
The 40-549 is a single pole power matrix module, suitable for switching inductive/capacitive loads up to 5A with 110VDC/250VAC hot switching and 400VDC/250VAC cold switching. It is available in single 16x4, single 8x8, dual 8x4 or single 8x4 configurations. Connections are made via a front panel 25 way D-type male connector. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. The module is suitable for applications requiring switching of either mains voltage or DC current.
-
40-132-202 -
Pickering Interfaces Ltd.
Pickering Interfaces 40-131/132 modules are a range of low cost, general purpose electromechanical relay cards. They are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.
-
40-132-101 -
Pickering Interfaces Ltd.
Pickering Interfaces 40-131/132 modules are a range of low cost, general purpose electromechanical relay cards. They are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.