Filter Results By:

Products

Applications

Manufacturers

Sound

tympanum, bioacoustic sensed pressure waves.

See Also: Ultrasound, Sound Calibrators, Audio, Infrasound


Showing recent results 541 - 555 of 577 products found.

  • PC based USB Real Time Analyzer

    Virtins Technology

    1) Measurement microphone and its accessories (a windshield and a microphone clip)2) XLR-to-USB Converter3) USB cable (1.5 m) 4) CD (contains the copy-protected Multi-Instrument Software) 5) USB hardkey (contains a Multi-Instrument Standard License)6) Audio Test CD (contains a list of audio test tones and noises) (AudioTestCD.zip or AudioTestCD.rar)7) 1/8” TRS cable (1.8m) 8) Black Soft Pouch Case 9) Individual Sound Level Calibration Data 10) Individual Microphone Calibration Data (only provided in RTA-168B)11) A small microphone stand

  • PCI 2 bit diagnostic card for Desk PC

    ST8661 - Shenzhen Sintech Electronic, Inc.

    1.This Card can work on Desktop PCI slot . Easy to install and fit with PCI slot.2.Court defects by difference sounds coding with build-in speaker.3. It can diagnosis the motherboard signal which show the problem of CPU, Memory, display card and so on.4.LED displays shows diagnosis result of motherboard. Especially helpful to pinpoint where is the problem when power on the computer and find no display or machine hang PCI bus reset and CLK signal working indicator.(When indicator LED is on to indicate its respective signal is fine.

  • HDMI / 3G Reference Media Player

    VQS-300 - VideoQ Inc

    Versatile destop/rackmount unit, loaded with unique sophisticated set of static and dynamic test patterns - see more details in separate VQL for VQS Presentation Multi-format HDMI and 3G-SDI outputs, digital and analog AV outputs 2.5 ppm accurate system clock to meet full 3G-SDI broadcast specs Front side bay for detachable SATA HDD – up to 2 TB of content VQL - Library of unique sophisticated dynamic test patterns and sequences LIve clips and 3D Video Tests, 5.1 Surround Sound and LR Stereo Audio Tests All commonly used resolutions, aspect ratios, frame rates and interlace modes Easy expansion with any external USB storage device: BD/DVD, HDD, FD.

  • Ultrasonic Distance Meter with Laser Target Pointer

    MS-98(2D) - MEET International Ltd.

    - Laser Target Pointer- Measurement range : 0.5m to 12m- Instant dynamic reading feedback- Auto area, volume calculation- Feet / meter conversion- Accumulate add distance calculation- Add calculation- Front / bottom measure- Memory clear function- Auto power off when not in use- Error warning with sound- Low battery warning- 6 digits LC display- Operating temperature : 0 ° C - 39 ° C (32 ° F - 102.2 ° F)- Unit size : 136 (L) x 56 (W) x 39 (H) mm- Battery type : 9V block one piece [battery not included]- Worldwide patent pending- Originated, designed and developed by MEET

  • Single Channel Instrument for General Acoustic / Vibration Measurements

    SVAN 979 - SVANTEK Sp. z o.o.

    SVAN 979 is the most advanced and powerful single channel instrument for general acoustic and vibration measurements ever made. The list of the instrument outstanding features and functionalities includes:- high accuracy sound and vibration measurements- most powerful frequency analysis package- time-domain (WAV) and Audio Events recording to Micro SD card- very high dynamic measurement range- extremely flat frequency response (digitally compensated)- extremely flexible set of interfaces (USB, Bluetooth, IrDA, RS232 and more)- USB Host port providing very flexible functional extensions capabilities- firmware ready for GPRS and WLAN communication (USB Host port)- GPS time synchronisation

  • Leak Noise Logger System

    LNL-1 - Fuji Tecom Inc.

    LNL-1 is an acoustic data logger system designed for detecting and monitoring leakage on water pipelines. * Loggers, equipped with high sensitivity sensors are deployed on pipe fittings such as valves, fire hydrants. The loggers record “minimum noise level” at the points on the pipeline.* Analyser, the recorded data are downloaded by radio communication by the Analyser. And the Analyser shows 3 levels of leak possibilities at given thresholds.* Software, the PC software identifies each logger and visualizes it on the map. The results of Minimum Noise Level are indicated in each area or blocks. The results are displayed as graph. Momentary change of sound is also displayed.

  • Voice Frequency Sweep-frequency Signal Generator

    CRY5520 - Hangzhou JiGao Electroacoustical Science and Technology Co.,Ltd

    CRY5520 Voice Frequency Sweep-frequency Signal Generator adopts a single-chip microcomputer to control sweep frequency. Digital and simulation is combined to have stable performance. It has very low distortion and is applicable for sound inspection of loudspeaker and earphone. It can operate in logarithm sweep frequency and manual frequency adjustment modes. Starting point, end point and time of sweep frequency can be set at will. Manual frequency adjustment is divided into rough adjustment and fine adjustment to accurately and rapidly adjust frequency. 12864 dot matrix liquid crystal display is adopted to display frequency and voltage value.

  • Vibration Testing

    Response Dynamics Vibration Engineering, Inc.

    We most often characterize a problem first and work from known conditions, and stay in “the known” as we proceed by making sense of what we observe as we move forward. We test and analyze the change in dynamics we are trying to create in real-time, on site, and often make changes to our experimental test plan on the fly as we discover how a system is actually behaving. In doing so we often get meaningful results from which we can make sound engineering decisions in a short time frame. We don't just make measurements and spit out data. We help identify the problem and propose solutions.

  • Finite Element Analysis

    Response Dynamics Vibration Engineering, Inc.

    An understanding of structural dynamics is very important to sound Finite Element Analysis (FEA). We have been performing FEA analysis for over 30 years and in most cases we have used experimental data to guide our modeling. While our engineers have had undergraduate and graduate courses in FEA, it is the years of modeling and analysis of existing structures that has taught us the most by forcing a thoughtful analysis of the key structural dynamics and then going though the process of making adjustments to boundary conditions, expanding the dynamics of the model in places, and making simplifications and approximations where possible.

  • Ultrasonic Concrete Testing

    Qualitest International Inc.

    This category comprises the range of instruments that use sound or stress waves in order to determine the properties of concrete and other materials non-destructively. The first and most widely used System is our V-Meter, which utilizes the ultrasonic pulse velocity method for evaluating construction materials in the field. Transducers are available for a variety of frequencies from 24 KHz to 500 KHz. This unit has also been modified to suit the special needs of ceramics users and can be found as the Ultrapulse. The PIES, our revolutionary Portable Impact-Echo System, is an advanced instrument for non-destructive detection of flaws and defects in a variety of civil infrastructures ranging from bridges, parking structures and buildings to dams, piles, tunnels, tanks and marine structures.

  • Digital AC/DC Auto-Ranging Clamp Meter

    PCMT20 - Pyle Audio Inc.

    Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit

  • Digital Audio Analyzers

    WinTek s.a.s.

    As regards the activity carried out by those in the call center it is important to note that much of the noise under which a trader is directly applied to the outer ear (acoustic signal from the headphone) and not, as usually happens, is only widespread environmental noise . For this reason they are different measurement methodologies normalized been identified that provide for a correction of the measured noise spectrum waves bring the same extent equivalent to the diffuse sound field in the vicinity of the attache head. The measurement techniques normalized are two: the first requires the measuring the acoustic signal with a probe placed in the operator''s ear canal (MIRE technique) but attention difficult to enforce; the second requires the measurement of an acoustic signal to the eardrum equivalent to that to which the operator is subject by the use of a system similar to those used in headphones, powered by an equivalent electrical signal and applied to a normalized anthropometric mannequin.

  • CLASS 2 MEASURING INSTRUMENT

    Bedrock SM30 - Bedrock Audio

    The Bedrock SM30, despite being our most basic model, is already packed with features and measurement modules. Moreover, its functionality is expended with the release of each new firmware update, at no charge. Class 2 / Type 2 sound level meter (fast, slow, A/C.Z-weighting, Leq) conforming to IEC-61672 class 2, ANSI S1.4 Type 2. Real Time Analyzer (1/3 and 1/1 octave)FFT analyzer (detailed frequency analysis up to 32768 lines). RT60 measuring (reverberation times: T20/T30/EDT). Calibrated audio recording. Leq long-term logging and averaging. Audio oscilloscope. USB audio device mode - calibrated audio for your PC-based software applications. More functionality will be added through free future firmware upgrades.

  • Combination Glove-Sleeve-Blanket-Line Hose Testing Equipment

    LSY,MSY,NSY Series - The Von Corp

    The LSY, MSY and NSY Series is The VON Corporation’s fully automated, microprocessor controlled test lab in a box. Units allow testing of Gloves, Sleeves, Blankets, Line Hose, Hoods and even Line Jumpers. All standard rubber goods can be tested, even class IV. All machine adjustments are controlled via a menu operated microprocessor control system. With a single selection the test voltage, current limit, depth, water fill level, test time, blower speed and exhaust fan speed are set. In the case of gloves, the operator is required to merely load gloves in the special clothespins, lower the test electrode into the glove and press the start button. Automated water fillers will fill the glove in less than 30 seconds. Tests are timed and an audible alarm sounds failures or test complete, with bright flashing colored lights signaling which position failed, or test complete. Other types of rubber goods are tested just as easily and automatically.

  • Compact Receiver

    UCR411a - Lectrosonics, Inc.

    The UCR411A receiver provides professional performance and a versatile feature set in a compact design for field and location production. All settings are made from the front panel with a powerful LCD interface, making the unit ideal for use in Quad Paks, on sound carts, in portable bags and in rack mount multi-couplers. To alleviate interference problems in an increasingly congested RF spectrum, an RF spectrum analyzer is built into the receiver. The receiver tunes across its 25.6 MHz tuning range and records RF activity with markers on the LCD screen. Finding clear operating frequencies is a quick, simple process. The UCR411A is compatible with all 400 Series Lectrosonics wireless transmitters (and some other transmitter types) and can be powered with internal 9V batteries or external DC.