  • Short Light Source

    LM-AS - Eddy Co.

    The short light source is compatible with the LM-101 or the LMC-20. The light is supplied with a 50 watt tungsten halogen convection cooled light source which provides suffcient energy for use with narrow band pass filters or monochronomators in the wave length range of .35 to 2.5 microns. The light beam is chopped at 200 hz by a quiet, vibration free, synchronous motor. The housing also contains a secondary LED light source and detector for synchronization of the amplifier, plus an electro-mechanical shutter to block the light output when the instrument is zeroed. An internal collimating lens produces a narrow beam (<1") so the LM-AS can be used in bell-jar and large coating systems.

  • Long Light Source

    LM-A - Eddy Co.

    The long light source is compatible with the LM-101 or the LMC-20. The light is supplied with a 50 watt tungsten halogen convection cooled light source which provides suffcient energy for use with narrow band pass filters or monochronomators in the wave length range of .35 to 2.5 microns. The light beam is chopped at 200 hz by a quiet, vibration free, synchronous motor. The housing also contains a secondary LED light source and detector for synchronization of the amplifier, plus an electro-mechanical shutter to block the light output when the instrument is zeroed. An internal collimating lens produces a narrow beam (<1") so the LM-A can be used in bell-jar and large coating systems.

  • UV Light Source

    Model 30 - OAI

    The Model 30 UV Light Source is highly efficient and may be utilized in a variety of applications. Light is collected by an ellipsoidal reflector and focused using OAI’s proprietary optical integrator which produces a highly uniform UV beam at the exposure plane. Using the appropriate lamp (included with the system), this UV Light Source is available in various beam sizes up to 24 inches square with output spectra ranging from 220 nm to 450 nm. Output power ranges from 200 watts to 5 kilowatts. All OAI UV Light Sources are equipped with quick-change filter assemblies, enabling the user to customize the output spectrum.

  • Power Source Unit

    SM7860 - HIOKI E.E. Corp

    Power Source Unit Ideal for MLCC Leakage Current Measurement. The SM7860 series allows for setting the dual-line output voltage on 8 channels or 16 channels, and enables up to 32-channel of output. The Hioki SM7860-5x/SM7860-6x series is a 32-channel, 500V / 1000V power source for the Hioki SM7810 Super Megohm Meter, providing positive and negative polarities required for MLCC test lines.

  • Remote Plasma Sources

    MKS Instruments

    Semiconductor and Electronic Thin Film applications use plasma sources to generate low-energy ions and radicals to react with material surfaces and chamber walls to remove contaminants and act as a precursor to aid in material deposition. MKS provides multiple options for radical generation including Toroidal and Microwave based Remote Plasma Sources supporting Fluorine, NF3, oxygen, nitrogen and hydrogen process chemistries.

  • Advanced Seismic Source

    GI-SOURCE - Sercel Group

    ​Sercel developed the GI-SOURCE to reduce and suppress the bubble oscillation from a single impulsive source to simplify processing. The GI-SOURCE impulsive source is based on the same technology as the GI-SOURCE but is different in that it has two independent air chambers within the same casing : the Generator (generating the primary pulse and creating the main bubble) and the Injector (injecting air inside the main bubble so that it collapses quickly).

  • Sound Source Localization

    HEAD acoustics GmbH

    In order to optimize product sounds, it is necessary to know the exact point of origin of a sound source. This makes possible to identify the cause of disruptive sound components and rectify these effectively, optimize sound radiation and thereby achieve the desired sound experience. The ease of use and advanced beamforming algorithms of the HEAD VISOR acoustic camera allow sound sources to be located precisely at the blink of an eye.

  • SGMA RF Source

    SGS100A - Rohde & Schwarz GmbH & Co. KG

    The R&S®SGS100A is an RF source designed to meet the requirements of automated test systems. It is available as a CW source or as a vector signal generator with an integrated I/Q modulator. With its frequency range of up to 12.75 GHz, the vector signal generation version covers the essential digital signals. The CW version can be used as a flexible local oscillator and for interference testing against mobile radio standards.

  • Precision Source Code

    Miniport Code - Perisoft

    We offer precision source code to jump start your development putting you close to the finish line right from the start.

  • Source Code Libraries

    Triangle MicroWorks Inc.

    We provide ANSI 'C' source code libraries for IEC 61850, DNP3, IEC 60870, and Modbus that can easily be ported to your device.

  • RR Signal Source

    Behlman Electronics Inc.

    Behlman’s RR series of Railroad Signal Sources and Frequency Converters are low cost, highly reliable, switch mode units built for Railroad Signaling. The RR series can be supplied with any single or three-phase input and outputs a clean, regulated AC signal at a precise frequency from 25 Hz to 250 Hz. These rugged signal sources are built to support the rigors of operating in the harsh environment of Railroad signaling equipment.

  • Calibration Light Source

    CAL1 - Image Engineering GmbH & Co. KG

    The one light source solution in the field of camera characterization and calibration. CAL1The CAL1 calibration light source is designed to characterize and calibrate cameras in the lab or on the production line. Its compact design consists of one iQ-LED element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Because of the non-reflective special diffusor filter on the sphere opening, a uniformity of more than 98% could be reached

  • Calibration Light Sources

    Sciencetech, Inc.

    An adjustable mount for Sciencetech''s line of calibration pen lamps.Power supply and pen lamp are not included. See the calibration sources brochure for more information.

  • LED Light Source

    FOD 113 - Fiber Optic Devices Ltd.

    The LED Light Source FOD 113 or FOD 114 is a light weight and a very small size portable device which has been created to become as popular as a cellular telephone or a pager. The devices of this series are equipped with a universal optical interface which allows quicker hook up to the line, thus saving time for complete measurements. The LED Light Sources meet TIA/EIA-526-14A requirements for coupling power into multimode fiber.

  • LED Light Source

    FOD 114 - Fiber Optic Devices Ltd.

    The LED Light Source FOD 113 or FOD 114 is a light weight and a very small size portable device which has been created to become as popular as a cellular telephone or a pager. The devices of this series are equipped with a universal optical interface which allows quicker hook up to the line, thus saving time for complete measurements. The LED Light Sources meet TIA/EIA-526-14A requirements for coupling power into multimode fiber.