  • LED Light Meter

    Extech LT40 - Extech Instruments Corporation

    The LT40 LED light meter is useful for measuring and optimizing environmental light levels in a wide range of environments, including office buildings, manufacturing plants and warehouses, university campuses, schools, hospitals, and many other locations. OSHA regulates workplace lighting because illumination must be adequate for assigned tasks, and light meters are used to verify regulatory compliance, as well as state and local public safety codes and ordinances. Use of LED lighting is on the rise because it is more efficient to operate, it emits stable, high quality illumination, and the technology is dropping in price. Besides LED lighting, the LT40 can measure standard light sources fluorescent, metal halide, high pressure sodium and incandescent up to 400,000 lux (40,000 Fc). The LT40 comes with a built-in sensor with protective cover, 2 AAA batteries, storage pouch, and user manual.

  • 2-port Battery Portable Passive Intermodulation Analyzer - iXA Series

    iXA - Kaelus

    The Kaelus iXA Series Passive Intermodulation (PIM) analyzer is a dual-port, battery powered PIM Test Analyzer. It supports multiple test scenarios such as testing at the top of the tower, the base of the tower, rooftop, in-building for DAS systems and external PIM Finding.No other PIM tester has ever been integrated to this level! The iXA includes a network of electronic switches to change from one-port to two-port measurement seamlessly. In addition, with integrated Range-to-Fault (RTF) on each port, the user can first troubleshoot the system for internal PIM. Then, without reconnection, the user can progress with the external PIM process, making the entire process much more efficient.With integrated RTF on each port, the user can collect four times more range-to-fault data than the standard 1-port PIM Finder solution. Thus, the user can easily locate and swiftly eliminate the strongest PIM source.

  • Manual Oscillators

    MOS-01, -01A - Compact Power Company

    The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.

  • Multi-Tester

    GWRMT001 - Grand Wing Servo-tech Co., Ltd.

    ◆To measure the Pulse Width transmitted by Transmitter for up to 9 channels. ◆To measure the Pulse Width sent from Receiver.◆To test the rotations of Servo automatically – at the pulse widths of top, medium and low points set by user already.◆To test the automatic rotations of Servo.◆To test the rotations of Servo by turning the knob on the tester manually .◆To test the sensitivity of Servo (1μS per step minimum).◆To measure RPM of a spinning propeller – for 2 – 6 blades ones, real time RPM value shown/to set the peak RPM value up to 99990 per minute.◆Shiny 4 digits red LED's to display the values measured.◆Power source can be from UM-4 / AAA cell x4, or an adapter with 7-15V or BEC (5V) from an ESC.◆An output port for applying Positive/Negative signals of Pulse Width from this tester.◆Four buttons for setting up functions and modes.

  • 96/48/24-CH Opto-22 Compatible Digital I/O PCI Cards

    PCI-7296/7248/7224 - ADLINK Technology Inc.

    ADLINK"s PCI-7296/7248/7224 are high-density parallel digital I/O boards with 96/48/24 I/O channels. The header connectors are fully compatible with industry Opto-22 standard. Thus, PCI-7296/48/24 can utilize the Opto-22 external devices. The PCI-7296/7248/7224 devices emulate mode 0 of the industry standard 8255 programmable peripheral interface (PPI) chips. The PCI-7296/7248/7224 provides 4/2/1 PPI chips respectively. Each PPI offers three 8-bit ports: Port A, Port B and Port C. The Port C is divided into 2 nibble-wide (4-bit) ports. The PCI-7296/7248/7224 devices have programmable timer/counters. One 16-bit counter is available for event counting, while the other 32-bit timer is available for timed interrupt generation. The PCI-7296/7248/7224 devices provide multiple programmable interrupt sources from DIO channels, as well as the output of the timer.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Timing And Sync

    Safran - Navigation & Timing

    Precision timing is critical for defense and commercial industries and powering essential network operations. Safran offers secure time servers and solutions for accurate network synchronization, ensuring security, compliance, and adherence to best practices. Safran excels in delivering precision timing solutions, including NTPNTP, or Network Time Protocol, is a widely used networking protocol that enables computers and devices to synchronize their system clocks with a reference time source. It ensures accurate timekeeping in computer networks by allowing devices to obtain precise time information from NTP servers, which are typically synchronized to highly accurate atomic clocks. NTP is essential for various applications and services that rely on synchronized time, such as network security, authentication, and data logging. time server appliances and GPSGlobal Positioning System is a navigation satellite system. See also master clocks globally.

  • Non-Contact H.V. Detector

    300 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP66.● 3 LED indicators in a circle for easier viewing in any directions (360° LED indication).● 8 voltage settings : 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV.● High bright LED visual indication.● With the longer shelter to make the 3 LED indicators brighter under the sun.● Sound indication.● The maximum voltage setting can be 500kV .● Self-test function.● Power source : 1.5V "C" type battery × 3.● High impact nylon casing.● Non-contact work by proximity.● Compatible with most hot sticks.● Lightweight, robust & compact. ● Suitable for indoor and outdoor use.● Easy access to batteries.● Special ranges are available upon request. ● The maximum detection range can be 500kV.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-8

  • Non-Contact H.V. Detector

    278 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP65.● 3 LED indicators in a circle for easier viewing in any directions (360° LED indication).● 8 voltage settings : 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV● Bright LED visual indication● Frequency range: 40~70Hz● Longer hood makes LED indicators more visible● Audible indication● Easy-to-prove method.● Self-test function● Power source : 1.5V "C" type battery × 3● High impact nylon casing.● Non-contact detection by proximity● Compatible with most hot sticks.● Lightweight, robust & compact.● Suitable for indoor and outdoor use.● Easy access to batteries.● Special ranges are available upon request. ● The maximum detection range can be 500kV.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-8

  • Fourier Transform Optical Spectrum Analyzer, 600 - 1700 nm

    OSA202C - Thorlabs, Inc.

    Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.

  • Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm

    OSA201C - Thorlabs, Inc.

    Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.

  • 96/48-CH Opto-22 Compatible PCI Express Digital I/O Cards

    PCIe-7248/7296 - ADLINK Technology Inc.

    ADLINK"s PCIe-7248/7296 are high-density parallel digital I/O boards with 96/48 I/O channels. The header connectors are fully compatible with industry Opto-22 standard. Thus, PCIe-7248/7296 can utilize the Opto-22 external devices. The PCIe-7248/7296 devices emulate mode 0 of the industry standard 8255 programmable peripheral interface (PPI) chips. The PCIe-7248/7296 provides 4/2 PPI chips respectively. Each PPI offers three 8-bit ports: Port A, Port B and Port C. The Port C is divided into 2 nibble-wide (4-bit) ports. The PCIe-7248/7296 devices have programmable timer/counters. One 16-bit counter is available for event counting, while the other 32-bit timer is available for timed interrupt generation. The PCIe-7248/7296 devices provide multiple programmable interrupt sources from DIO channels, as well as the output of the timer.

  • Video Pulse Generator

    MS 1811 - Meltronics Systemtech

    *4 Channels of Variable Pulse / Amplitude Output*Pulse Generation Delay between any Two Channels can be Programmable between 2ns to 1ms*Pulse Width can be programmed from 20ns to 268ms (Range: 60ns � 2Sec, Resolution: 2ns, Accuracy: �5ns)*Programmable Pulse PRI (Range: 0ns � 2Sec, Resolution: 10ns, Accuracy: �5ns)*Delay Amongst Channels (Range: 0 � 1.34S, Resolution: 2ns, Accuracy: �5ns)*Rise Time and Fall time is less than 5ns (Programmable Slew Rate 2ns to 10ns � Optional)*Pulse Amplitude can be Programmed between 50mV to 6V (Range: 0 � 6V, Resolution: 10mV)*Channels can be terminated with different loads (50W,75W and 90W)*Standard ISA Bus Interface*Clock (Frequency: 100MHz, Source: Internal/External)*Driver interface for Windows2000/XP/VISTA and LINUX OS

  • Safety Compliance Test System

    EN 60601 - LXinstruments GmbH

    Test system for electrical safety compliance testing of medical products in accordance with EN 60601-1, 3rd edition.The system is equipped with three test fixtures which are connected in parallel order to reduce the number of setup tasks for different variants in the course of day-to-day manufacturing processes. Its purpose is to test medical products, e. g. patient monitors, which are employed at hospitals to monitor heartbeat and oxygen saturation.Based on the integrated electrical safety tester by Associated Research, in combination with an AC power source and a switching matrix, it is possible to fully automate tests like for instance AC/DC high-voltage tests, insulation resistance measurements, earth connection tests and leakage current measurements.The required occupational safety is provided by a high-voltage safety hood in accordance with EN 501191. The entire safety technology, as well as the control PC, is mounted in an aluminum-profile cart.

  • Cold Atomic Beam System

    AOSense

    Detailed description of item: Complete cold atomic beam sources for alkaline-earth precision experiments and atomic devices. Small chambers with patented permanent-magnet Zeeman slowers and in-vacuum 2D MOT optics allow high flux with low outgassing and no thermal beam flux at the cold atom port, which provides a CF-133 connection to customer vacuum chamber. Advanced thermal design of the effusion oven allows long-lifetime operation at minimal heating power, with no water cooling. An integrated low-outgassing hot window is provided for coupling of on-axis Zeeman cooling light. Ion and getter pumps integrated into the chamber manage outgassing from the oven at temperatures up to 520 °C. Operating baseline pressures below 1×10-11 mbar can be attained in the customer’s downstream cold atom (typically 3D MOT) science chamber, with suitable pumping speed provided at the differentially-pumped cold beam output port.