Bunkoukeiki Co., Ltd
It is used to measure the spectral response (spectral sensitivity) of photoelectric conversion devices (photodetectors / sensors) such as silicon photodiodes and CCD · CMOS image sensors . Measurement in the broadband wavelength region can be performed with low stray light.
-
Photo Emission Tech., Inc.
QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.
-
LP471LUM2 -
Delta OHM S.r.L.
Photometric probe for measuring the LUMINANCE, spectral response according to the photopic curve, angular field 2°.
-
UVS-A-T -
Kipp & Zonen B.V.
The UVS-A-T has a broad spectral response optimised for precise measurements of atmospheric UV-A irradiance.
-
LXP-2 -
Sonel S.A.
The digital light meter is a precision instrument used to measure illuminance (Lux, footcandle) in the field. It is meet CIE photopic spectral response. It is fully cosine corrected for the angular incidence of light. The illuminance meter is compact, tough and easy to handle owing to its construction. The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral response filter.
-
FRF -
Crystal instruments
FFT Spectral Analysis. Frequency Response Function (FRF) is a commonly used measurement type of the Dynamic Signal Analyzer. FRF is defined as the ratio of response i.e. acceleration, velocity, or displacement with respect to the excitation force which is the reference.
-
LPPHOT03… Series -
Delta OHM S.r.L.
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
LP471PHOT -
Delta OHM S.r.L.
Photometric probe for measuring the ILLUMINANCE, spectral response according to the photopic curve, class B according to CIE N° 69, cosine correction diffuser.
-
LP471P-A -
Delta OHM S.r.L.
Combined probe for measuring ILLUMINANCE (lux), with standard photopic response, and IRRADIANCE (μW/cm²) in the UVA spectral range (315…400 nm, with peak at 360 nm).
-
Apogee Instruments, Inc.
Apogee silicon-cell pyranometers feature a monocrystalline silicon-cell detector that has the same spectral response as a PV module. The sensors quantify shortwave radiation being harnessed as electricity.
-
CGR 4 -
Kipp & Zonen B.V.
CGR 4 pyrgeometer is an instrument for the highest quality scientific measurements. The specially designed meniscus dome provides a 180 field of view with negligible directional response error. A hard-carbon coating on the outside of the dome smoothes the spectral response and provides extra protection to the silicon surface.
-
Inphora Inc.
Besides the described types Inphora can supply detector-filter combinations with parameters matching the customer's special requirement, with different sized housing, without housing. If the application determines the detector's spectral responsivity, we can achieve that with a filter designed exactly to the specifications. CCD cameras with unusual spectral sensitivity functions can be matched with filters to obtain CIE tristimulus response or photopic response. Similarly, photmultiplyers can be matched also with INPHORA filters. When determining parameters for a custom detector-filter combination several details have to be considered:
-
PM-3 -
Lumetronics
Is a compact, lightweight & easy to use Illuminance meter. The sensor is a highly stable silicon photo diode having a wide measuring range. Its spectral response is closely matched with the CIE relative photopic luminosity curve by multi-element glass filters. The sensor is also cosine corrected for true response at variable incidence angles.
-
UVS-B-T -
Kipp & Zonen B.V.
Compared to the spectral response of the UVS-E, the UVS-B-T has a sharper cut-off at the transition from UV-B to UV-A. This feature reduces the UV-A contribution to the radiometer output and permits the highest possible correlation to atmospheric UV-B irradiance.
-
UVS-E-T -
Kipp & Zonen B.V.
The UVS-E-T has a spectral response that is adapted to the erythemal (sunburn) action spectrum of the human skin (CIE 1987 weighting). Hence, this radiometer collects information of medical and public concern: UV Index, UV Erythemal dose and dose rate.