Filter Results By:

Products

Applications

Manufacturers

Standards

A controlled reference or acknowledged technical criterion.

See Also: IEC, IEEE, Mil, Interoperability Test, Compliance


Showing results: 4621 - 4635 of 6646 items found.

  • Tungsten Probe Tips

    T-4 Series - Picoprobe

    T-4 tips are for use in most standard commercial micropositioners for probing integrated circuits, pads, or lines. Each T-4 tip uses the same 10, 22, 35, 60, or 125 micron diameter tungsten wire as our Model 12C Picoprobe, but is mounted to a 0.020 inch diameter, 2 inch long tinned copper shaft.

  • SpaceWire Physical Layer Tester

    141 - STAR-Dundee

    The SpaceWire Physical Layer Tester (SPLT) is a tool designed to test, validate and verify a SpaceWire system across all levels of the SpaceWire standard. Two SpaceWire ports employ a special LVDS interface which allows the transmitted signals to be deliberately and measurably manipulated to test the capability of a unit under test to receive signals of varying quality.

  • PXI/PXIe USB Data Comms Multiplexer, 8-Channel

    42-737A-901 - Pickering Interfaces Ltd.

    The 40-737A-901 (PXI) and 42-737A-901 (PXIe) are 8:1 USB multiplexers for switching USB1 and USB2 data and power connections with USB connectors. The data signal paths are 2-pole arranged as differential pairs as defined by the USB standard. The signal pair has a controlled differential impedance and the multiplexer has been designed for minimum insertion loss.

  • W-CDMA/HSPA+ Analysis Using NI PXI RF Test Instruments

    RFmx W-CDMA/HSPA+ - NI

    The NI-RFmx W-CDMA personality is a highly optimized API for performing physical layer measurements on W-CDMA cellular standard signals. NI-RFmx W-CDMA is completely interoperable with all NI-RFmx APIs. It provides simple access to the most advanced optimization techniques such as multi-measurement parallelism and multi-DUT measurements. The result is extremely fast and high-quality measurements with minimal software development efforts.

  • High Resolution Laser Axis Board

    N1225A - Keysight Technologies

    The Keysight N1225A provides ultra-sensitive fiber optic receivers and high resolution distance measurements for high performance positioning systems using laser interferometry with VME bus systems. Multiple N1225A boards can be linked together for up to 31 axes of position measurement. Includes "oscilloscope like" data capture operated with standard web browsers.

  • Industry Pack Carriers and Digital I/O

    CPCI-2IPC-6U - ALPHI Technology Corporation

    The CPCI-2IPC-6U module provides a high performanceflexible I/O scheme, that supports industry standard IndustryPacksÔ. For application requiring high performance, highdensity I/O or unique combinations, the CPCI-2IPC-6U is theperfect solution. The Local DSP’s can be used to simplymove data to and from the CPCI bus or provide localprocessing functions such as local PID controls, FFT’s, digitalfiltering, etc.

  • Bench Top MicroPress

    LTP-250A - Lambient Technologies

    Test labs and university researchers need reliable, robust solutions for applying heat and pressure to samples. But standard industrial presses are too powerful and costly, and can take up too much space. Organizations responsible for small parts molding applications and composite materials development and testing need press solutions optimized for their specific materials and testing environments.

  • TVAC CalPod, 20 GHz

    85532B - Keysight Technologies

    CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button, and without removing the DUT or re-connecting standards. Very useful in thermal-vacuum chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the testing to perform a normal re-calibration.

  • PCIe-8431, PCI Express, 8-Port, RS485/RS422 Serial Interface Device

    780592-01 - NI

    The PCIe‑8431/8 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between … 4‑ and 2‑wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • PXIe-8431, 8-Port, RS485/RS422 PXI Serial Interface Module

    781473-01 - NI

    The PXIe‑8431/8 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.

  • Digital Color Camera for Microscopy

    LC30 - Olympus Corp.

    The LC30 is a 3.1 megapixel digital color camera for microscopy that combines versatility with performance. The LC30 is the ideal entry-level microscope camera for quality bright-field imaging - suitable for material science applications. The Olympus LC30 color camera for microscopy combines versatility with performance. With up to 37 frames per second (fps), faithful color reproduction, full integration into Olympus imaging platforms, and an excellent cost-performance ratio, the LC30 is the ideal entry-level microscope camera for quality bright-field imaging - suitable for material science applications.. The sensitivity and frame rate of the 3.1-megapixel CMOS chip can be increased using various binning modes, resulting in easy observation and focusing. The LC30 camera can be quickly and easily mounted on all microscopes equipped with a standard C-mount adaptor, and requires only a single USB 2.0 cable for high-speed data transfer and power supply. Its complete integration into the OLYMPUS Stream imaging platforms helps ensure the seamless interaction of microscope, camera, and additional devices, delivering intuitive and efficient operation.

  • Digital Power Meter

    66203/66204 - Chroma ATE Inc.

    Chroma 66203/66204 Power Meters are designed for mul t ipl e pha s e powe r me a surement applications. The wiring mode function allows the user to take accurate power measurements for various wiring modes 1P2W/1P3W/3P3W/3P4W as well as providing accurate standard power measurements common for most electrical devices. A unique feature of the 66203/66204 is its stateof- the-art DSP digitizing technology instead of less accurate and slower traditional analog circuits. The internal 16 bits analog/digital converters with sampling rates of up to 250kHz provide both high speed and high accuracy measurements which is unprecedented within the industry for this class of power meters. The instruments include a four part display with 7-segment LED front panel readouts. Users can easily select desired parameters and readouts with a touch of a button. The 66203/66204 meters also include remote control using USB or GPIB interfaces via rear panel connections.

  • Dual Channel Multi-Band FM Tracking/Data Receiver In Modular Style Housing

    LS-27-B - Lumistar Inc.

    The Lumistar LS-27-B Modular Dual Channel Tri-Band Tracking and Data Receiver is Lumistar’s third generation of modular high performance FM Receivers. This wideband designs supports one or two independent channels of PCM with data rates up to 20Mbps. The unit includes both an optional FM demodulated output for PCM data, and standard programmable AM/linear AGC outputs for auto-tracking receivers. The design offers 8 IF Bandwidths and 8 Video Filters per channel for each receiver.AC coupling with a low pass filter is employed to ensure a high quality data link with long strings of NRZ-L ones or zeroes. The unit provides a software selectable 10 MHz reference I/O port forlocking local oscillators to a high precision external source or to arrange multiple units in a master/slave arrangement. The receiver’s control and status is achieved via Ethernet, USB or auto-switched RS-232 (or “4-wire” RS-485 in place of 232). When utilizing the RS-422 interface, multi-drop configurations can be accommodated.

  • Noise Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

Get Help