Filter Results By:

Products

Applications

Manufacturers

Strain

a strenuous force that pulls.

See Also: Strain Gages, Stress, Extensometers, Fatigue


Showing results: 466 - 480 of 513 items found.

  • Ozone Aging Test Chambers

    Dongguan Amade Instruments Technology Co., Ltd

    Ozone aging test chamber is also called as ozone climate simulator or ozone aging tester. It is one of climatic testing instruments, which is to simulate and intensify the ozone condition for determining the cracking resistance of vulcanized or thermoplastic rubbers when subjected to dynamic or static tensile strain exposed at a man-made constant temperature to atmosphere containing given concentration of ozone in conformance with relevant specification. Ozone test is an indispensable method for people to research effects and mechanisms of ozone on rubbers, quick identify and evaluate anti-aging performance of rubbers and find solutions for improvement of quality and lifespan.

  • Terminal Test Kit (19 PCS)

    3605 - Peaceful Thriving Enterprise Co Ltd

    1. Check high and low voltages (power and ground) on 6, 12 and 24V system.2. 4mm connection for banana plugs.3. LED indicates red for power (high) and green for ground (low).4. High impedance protects sensitive electronic ignition components.5. Connects red lead to power source and black lead to ground source.6. 1.8m long heavy-duty dual leads with battery clips and spring strain relief.7. Facilities the measurement on connectors and components without destroying the insulation or the plug connection.

  • Socket Wrench Torque Sensor Rotating Type

    RSS SERIES - Transducer Techniques, Inc

    Our RSS Series rotating socket wrench torque sensors are available in ranges from 10 ft-lbs. through 250 ft-lbs. and provide accurate measurements of bolt or nut wrenching torques. These sensors are bi-directional so both tightening and break-away torques can be measured. Unlimited rotation of the ball bearing supported sensor shaft allows monitoring of the total fastening cycle. The sensing element incorporates bonded foil strain gages of the highest quality, along with coined silver slip rings and two silver graphite brushes per ring for data transmission.

  • Rotating Dual Shaft Torque Sensors

    RST SERIES - Transducer Techniques, Inc

    The RST- Series is our low range rotating torque sensors that are available in eleven full scale ranges of 10 through 30K inch pounds. The sensing element incorporates bonded foil strain gages of the highest quality along with coined silver slip ring and silver brushes for data transmission. The WR2, Flexural Natural Frequency, and Torsional Stiffness values as stated in the Dynamic Characteristics box below, are approximate and the tabulated data pertains to the torque pickup only, and does not include the effects of couplings or other rotating masses that would be part of a dynamic system.

  • Strainer-Recorder

    ViTec Co. Ltd

    To ensure reliable operation of the measuring complex in the harsh conditions of ice tests, it is based on the industrial measuring platform NI CompactRIO, which provides mechanical strength and operation at negative temperatures.The system provides for operation both under the guidance of an operator with displaying the voltages removed from the ship's hull in the form of graphs on a computer screen connected to the strain gauge station via an Ethernet line, and in stand-alone mode, when the recording of a given duration is initiated by the station on pre-configured events: amplitude exceeding by one of channels, an external discrete signal or periodically at specified intervals.

  • NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle

    865682-01 - NI

    NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.

  • High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)

    Model 7651 - Jinan Testing Equipment IE Corporation

    Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.

  • Pressure Sensors

    Sensata Technologies

    Whatever configuration you require, look to Sensata. Our devices span a spectrum of pressure ranges, configurations and form factors.High pressure (>750psi / 50bar)Micro Silicon Strain Gauge solutions provides rugged reliability and a hermetic seal for a wide variety of environmentsMid pressure (100 to 750psi / 6 to 50 bar)Ceramic capacitive or MEMS solutions offer a wide range of solutions tailored to application needs at superior valueLow pressure (inches of water to 100psi / 2mbar to 6 bar)MEMS solutions including TPMS offer extremely low power consumption and wireless connectivity

  • Shock Test System

    Labtone Test Equipment Co., LTD

    Products are inevitably affected by impact, bump, free fall, tumbling etc. during production, transportation, loading and unloading as well as during the use of the products. All of these are transient excitation on the object, causing the object to produce mechanical characteristics of high speed, acceleration, strain rate instantly. These kind of characteristics are completely different from that in static load, and may cause problems to the object in terms of structural strength and stability and sometimes the object may fail. Therefore, it's necessary to study the effect of impact and reproduce the shock environment, to assess the structural strenghth and performance of the object under shock environment.

  • 24-Bit Precision Load Cell Input Card

    PCI-9524 - ADLINK Technology Inc.

    The PCI-9524 is a robust, multi-purpose module designed for turnkey material test systems (MTS). Equipped with four strain gauge-based transducer input channels, four general purpose analog input channels, and a 3-axis motion controller, the PCI-9524 delivers a complete hardware solution for MTS manufacturers. The PCI-9524 easily integrates physical quantity measurement and implements strategy of close-loop control in a single module package. For transducer measurement, the PCI-9524 supports sensitivity from 1.0 mV/V to 4.0 mV/V and provides a 1/200000 accuracy of measurement of full scale. These features make the PCI-9524 suitable for precise measurement in large-scale transducers.

  • PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    781345-01 - NI

    102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.

  • NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle

    865685-01 - NI

    NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9220, cDAQ-9171, and cRIO-9940 includes the NI-9220 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9220 features 16 channels and 16 simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. Additionally, you can use the NI-9220 to generate 3.2 MB/s of data at the maximum sampling rate.

  • Miniature Axial Extensometers

    Model 3442 - Jinan Testing Equipment IE Corporation

    Weighing as little as 8 grams, these miniature extensometers are designed to have very low operating force with minimal specimen influence. All use an improved version of Epsilon’s dual flexure design which makes them very rugged for their size. With a module height of 15.2 mm (0.6 inches), they will fit in the limited space between grips that is typical with small test samples. Gauge lengths can be as short as 3 mm or as long as 50 mm. A newly designed gage setting pin and assembly allows the gauge length to be set accurately and repeatably to ASTM and ISO requirements for all gauge lengths. Reengineered quick attach wire forms provide simple and secure specimen attachment. Wire forms for round and flat specimens are included, as well as flat, 3-point, and vee knife edges. The wire forms may be removed to enable mounting using elastic bands or springs. A tethering attachment point provides fall protection and enables counterbalancing of the extensometer’s weight when testing delicate specimens.Model 3442 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller and Epsilon will equip the extensometer with a compatible connector wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of solutions for signal conditioning and connection to data acquisition systems, chart recorders, or other equipment.

  • Sensor for High-End Applications

    ARAMIS SRX - GOM GmbH

    The new ARAMIS SRX is a 3D measurement system for dynamic evaluation of 3D coordinates, 3D displacement and surface strain. It comprises the latest camera technology including 12-megapixel cameras. Capturing up to 2000 images per second, the sensor is especially designed for rapid testing applications. It comes with an additional setup for crash applications providing an image acquisition rate of 1000 images per second in HD format. With the combination of high resolution and high speed, the ARAMIS SRX sensor is perfectly suited to high-end applications. The sensor is designed for high stability, process reliability and user-friendliness, which is why it is primarily used in industrial environments and applications.

  • Contactless Laser Extensometers

    Jinan Testing Equipment IE Corporation

    Model LE-05 and LE-15 extensometers measure strain optically, without contacting the specimen, using laser diode technology. The extensometers are self-contained and portable. They may be interfaced with a variety of testing machines and data acquisition systems using the ±10V analog output or bi-directional RS-232 serial port. Operation may be local or remote. A digital display is included. The scanning beam is always perpendicular to the specimen, unlike most laser extensometers. This eliminates errors when viewing through windows in chambers. It also minimizes sensitivity to the distance between the extensometer and the sample. Because the unit measures reflected light, no receiver is required behind the sample.

Get Help