Showing results: 1 - 15 of 40 items found.
-
Cryogenic Ltd.
The AC Susceptometer option uses a small primary excitation coil to apply an AC field to a sample (typically 1mT at frequencies from 0.1 Hz 10000 Hz). A pair of secondary pick-up coils positioned close to the excitation coils are used to detect the sample response. The resultant signal is measured using a Lock-In amplifier with the in-phase and out-of-phase components of the signal corresponding to the real and imaginary components of the AC Susceptibility of the sample. An additional compensation coil is used to eliminate background signals.
-
SM-20 -
GF Instruments, s.r.o.
The SM-20 magnetic susceptibility meter is very useful tool for a number of geological and geophysical applications where the unique sensitivity of 10-6 SI units together with its small, shirt-pocket size and low weight are appreciated.
-
CS Analyst™ -
EMI Software llc
With CS Analyst circuits can be analyzed prior to fabrication to determine whether conducted susceptibility requirements will be satisfied. CS Analyst is ideally suited for predicting the effectiveness of EMI filtering for power line and signal line filters and for determining the effects of cable shielding and shield terminations.
-
King Design Industrial Co., Ltd.
*Equipment conforms to IEC61730 MST12 specification.*Pre- or post-round can be selected for control wiring connection.*With weights block’s positioning pin is removed before test; and is inserted in the rear positioning hole for the remaining time.*Equipped with rings at both front and rear end; used to connect a rope and control the driving direction.*Use replaceable special cutting chip.
-
MULTI KAPPA -
GF Instruments, s.r.o.
Multi Kappa instrument serves for fast field survey allowing both spot measurement and mapping by means of several probes. Together with GF Instruments traditional pocket magnetic susceptibility meters cover wide range of demands for accurate susceptibility measurement on ground surface, outcrops and samples of rock and soil. geological survey, archaeology, agriculture and forestry, raw material prospecting, mineralogy, sedimentology, detection of metallic objects, UXO survey.
-
EM-6954 | 70 MHz – 1 GHz -
Electro-Metrics Corp.
The EM-6954 is designed to meet antenna requirements for both field strength measurement and radiated susceptibility in the 70 MHz to 1 GHz frequency range.
-
2654-1 -
Solar Electronics Company
The Solar Model 2654-1 Lightning Generator synthesizes electrical impulses needed for testing susceptibility to transients induced in aircraft equipment by lightning strikes.
-
Model 9910 PurePulse/PinScan -
Electro-Tech Systems, Inc.
Model 9910 PurePulse / PinScan is used to determine the ESD susceptibility level of electronic devices up to ±4kV. PurePulse generates ESD pulses up to 4kV for testing electronic devices for susceptibility to Electrostatic Discharge (ESD) using HBM, MM and HMM models. PinScan provides automatic sequencing of ESD testing of up to 128 pin devices, applying a discharge, thenperforming a curve-trace test to identify a failure.
-
L-3 Cincinnati Electronics
Our Environmental Services Group performs emissions and susceptibility testing to ensure a product meets its intended performance in the ever-increasing and challenging electromagnetic environments.
-
GPS7500 -
Noisecom
The programmable GPS7500 Noise & Interference Generator is capable of generating up to a 40 MHz wide noise or interference band for GPS receiver susceptibility testing.
-
Aero Nav Laboratories, Inc.
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
Aero Nav Laboratories, Inc.
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
Aero Nav Laboratories, Inc.
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
McLAREN Applied Technologies
This sensor uses a K-type Chromel/Alumel thermocouple and is intended for use in high-temperature, high-vibration environments. Control units and data loggers support K-type thermocouples. The sensor is short and compact to minimise its susceptibility to vibration.
-
ACR Systems Inc.
An external Relative Humidity and Temperature Probe for tight or remote locations. Every RH reading is temperature compensated for accurate readings. For environmental susceptibility, see Data Logger specification. Maximum extension is 30m (100').