  • MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)

    SCR ELEKTRONIKS

    The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.

  • AOI Handlings System

    MicroContact AG

    The AOI handling system is a compact facility with various test units. Via an ionization cleaning station the ceramics are transferred to the contacting station. There, the resistance values of the substrates are tested with a rigid needle adapter. Afterward, the ceramics are further conveyed to the three (optionally four) AOI test stations (for automatic optical inspection) and are tested for cracks, unevenness, faulty imprints, contamination, etc. The poorly evaluated ceramics arrive at a review station where the operator can assess and evaluate the errors on the monitor. If the operator is uncertain about a fault, the ceramic in question can be positioned under the microscope position and inspected by eye. Poorly defined ceramics are marked accordingly with an ink pen.

  • Modulation Distortion Up To 70 GHz

    S930707B - Keysight Technologies

    S930707B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 70 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930707B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 8.5 GHz

    S930700B - Keysight Technologies

    S930700B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 8.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930700B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 26.5 GHz

    S930702B - Keysight Technologies

    S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 50 GHz

    S930705B - Keysight Technologies

    S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 90 GHz

    S930709B - Keysight Technologies

    S930709B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 90 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930709B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 13.5 GHz

    S930701B - Keysight Technologies

    S930701B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 13.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930701B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 125 GHz

    S930712B - Keysight Technologies

    S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 43.5 GHz

    S930704B - Keysight Technologies

    S930704B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 43.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To And Beyond 125 GHz

    S930713B - Keysight Technologies

    S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Mechanical Creep and Rupture Testing Machine

    MRC Series - Jinan Testing Equipment IE Corporation

    MRC series mechanical creep and rupture testing machine with single-lever structure is designed for long-term creep and stress rupture test applications. The series mechanical creep and rupture testing system is mainly for the metallic materials under room or elevated temperature according to GB/T2039, GB/T 20120, EN ISO 204-2009 and ASTM E139. The creep and rupture testing machine can also maintain constant loads for extended periods of time. Through the mechanical advantage of the lever arm loading system, constant loads can be maintained with a high degree of accuracy for long duration. This creep and rupture tester uses dead weights without continuous operation and the dependency of a mechanically powered drive. The creep and rupture testing system is an ideal equipment for metallurgy manufacturer, research institute, colleges and other relevant factories and mines.

  • Wafer/Chip/Package Semi-automated ESD Tester

    400SW - Tokyo Electronics Trading Co., Ltd.

    Semi-automated ESD tester featuring Ecdm 400E, Universal ESD Simulator. Used with a manual wafer probing system or a die manipulator, wafer or die level semi-auto ESD test can be done, as well as packaged device test. Damage is detected by V-I curve or leakage current change detection.

  • Desktop Tunable Laser Source

    UC8110 - UC Instruments, Corp.

    The UC8110 desktop tunable lasers offer superior performance for the test of DWDM components, AWG & PLC components, optical amplifiers, DWDM system and other general purpose of fiber optical test and measurement applications. It is a wavelength high accuracy, high power output, small dimension, fast startup, affordable tunable laser source system. UC INSTRUMENTS provides C band, L band, or C+L band tunable laser sources options.

  • PulseTech Battery Analyzer, 6V and 12V Battery Tester

    390PT - PulseTech Products Corp.

    The 390PT Battery and System Tester lets you quickly, safely and accurately test both 6-Volt and 12-Volt lead-acid flooded, AGM (flat and spiral plate) and gel cell batteries in or out of the vehicle and test 12-Volt and 24-Volt charging systems for proper operation. Combined singe load, dynamic resistance technology and algorithms display battery voltage and capacity in easy to understand results in seconds. The handy "QUICK START" instruction guide is printed on the back of the tester.