Filter Results By:

Products

Applications

Manufacturers

System Test

Testing conducted on a complete, integrated system to evaluate the system's compliance with its specified requirements .

See Also: Systems, Equipment, Test Systems, System Integrators


Showing results: 3796 - 3810 of 4500 items found.

  • sbRIO-9229 , Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780874-01 - NI

    Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.

  • NI-9239 , ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780181-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • NI-9239 , ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    782402-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • NI-9239, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    779593-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • 802.11ad Testbed, Reference Solution

    Keysight Technologies

    Generate and analyze 802.11ad fully coded PHY waveforms for complete component, subsystem, and system performance at baseband, IF, and millimeter-wave. This Reference Solution combines Keysight Technologies software and hardware to provide a flexible testbed for 802.11ad waveform generation and analysis. Software provides the flexibility to generate and analyze 802.11ad waveforms with a wide range of different attributes. Hardware provides the flexibility to support baseband, IF, and millimeter-wave test planes. Create waveform sequences with unique 802.11ad packet structures including Modulation Coding Scheme (MCS), packet length, payload data type, and interpacket gap length, etc.

  • PXIe-1095, 18-Slot, Up to 24 GB/s PXI Chassis

    783882-01 - NI

    PXIe, 18-Slot, Up to 24 GB/s PXI Chassis—The PXIe-1095 features a high-bandwidth backplane and 58 W of power and cooling in every slot to meet a wide range of high-performance test and measurement application needs. The chassis incorporates two hot-swappable power supplies to improve the mean time to repair (MTTR) of the PXI system; it also offers an optional timing and synchronization upgrade that includes a built-in oven-controlled crystal oscillator (OCXO) for increased clock accuracy and external clock and trigger routing. It accepts PXI Express modules in every slot and supports standard PXI hybrid-compatible modules in up to five slots.

  • Instrument Bracket Kit, w/ Strain Relief, Slide Configuration, for 28"+ Slide Kits

    310113002 - Virginia Panel Corporation

    Instrument Bracket Kit, w/ Strain Relief, Slide Configuration, for 28"+ Slide Kits Similar to instrument bracket p/n 310113453, but includes cutout to accommodate air intake on NI PXIe-1088 chassis. Only compatible with slide configurations 28" and longer. Not compatible with cable tray. Not recommended for use with 2+ tier 90 Series systems (905, 9075, etc.).Used to mount testing instrument to slides and also allows test instrument to slide out for maintenance access. Provides strain relief in front area of bracket. Compatible with chassis (see drawing for more information)

  • 9050 Slide Mount

    Virginia Panel Corporation

    The 9050 Slide Configuration provides maximum test system versatility. This configuration allows for easy instrument wiring and chassis access which allows for shorter cable lengths and a flush rack mount to save valuable work space.Ordering has been simplified with packages offered that include the 9050 receiver, receiver mounting plate, flanges and instrument bracket. Slide kits are available in depths designed to fit most common racks. To determine the slide kit needed, measure rack depth between mounting rails. Slides are rated to support 180 lbs (81 kg) to accommodate even the largest fixtures.

  • Combo Unit, 7.5 Digit Digital Multimeter (DMM) with 10-Bit 1GHz Digitizer in a Single VXI Slot

    6084A - Astronics Corporation

    Increases test system performance and density with this combo unit, which packages a 7.5 digit Digital Multimeter (DMM) together with a 10-bit, 1 GHz Digitizer into a single VXI slot.Replaces the Wavetek 1362 DMM, Analogic DBS Series, and Agilent VXI DigitizersDigitizer with 4 Inputs, 10-bits, 1 GHz, up to 4 GS/s and Ranges up to 500V DMM with 7.5 Digits for DC Volts, Current and Ohms with AC Volts up to 1 MHzIVI-COM Drivers and Soft Front Panels ProvidedMore Dynamic Range (by 20 dB for DMM and 12 dB for Digitizer) for Better Legacy Range Mapping

  • Bolt Extensometers for Proof Load Testing

    Model 3565 - Jinan Testing Equipment IE Corporation

    The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • Energy Meter Test Bench

    SP-6103 - Shanghai Powoo Industry Develop Group Limited

    - Single phase energy meter test bench - auto-calibration system - accuracy class: 0.1/0.2 class - Standard CT; 0.01/0.02 - output voltage: 0-220V9240V option); range: 0-120% - fine adjustment: 0.01% - output current: 0-100A; (option for 200A)- fine adjustment: 0.0001A (min)

  • Primary Test Manager

    OMICRON electronics

    The Primary Test Manager™ (PTM) software supports you during diagnostic testing, condition assessment and data management of medium- and high-voltage assets, such as circuit breakers, rotating machines, grounding systems, instrument and power transformers as well as bushings and on-load tap changers (OLTC).

  • Pitot Static Test & RVSM Air Data Accs Kits

    ADA320-723 - Nav-Aids Ltd

    Kit Model ADA320-723 (Bar type) contains the equipment required to connect the Air Data Tester to the pitot and static ports, for the performance of a complete test of the main and alternate Air Data System of the Airbus Industries A-319, A-320, A-321 aircraft. The equipment is approved by Airbus Industries.

  • HV Calibration

    B-1027 - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation’s High Voltage Calibration Lab provides high accuracy capability for conducting tough reliability tests on all our high voltage devices. In this facility we test and calibrate HV Relays, HV Dividers, HV Probes, Spark Gaps, our Fiber Optic Systems, and HV Digital Voltmeters up to 450kV. We provide our own in house test lab to ensure Ross products meet or exceed required safety standards as well as our own high standards of dependability, long life and quality. Our technicians use test equipment calibrated by or traceable to National Institute of Standards and Technology or other national metrology institute to provide the highest in testing accuracy.

  • Miniature Axial Extensometers

    Model 3442 - Jinan Testing Equipment IE Corporation

    Weighing as little as 8 grams, these miniature extensometers are designed to have very low operating force with minimal specimen influence. All use an improved version of Epsilon’s dual flexure design which makes them very rugged for their size. With a module height of 15.2 mm (0.6 inches), they will fit in the limited space between grips that is typical with small test samples. Gauge lengths can be as short as 3 mm or as long as 50 mm. A newly designed gage setting pin and assembly allows the gauge length to be set accurately and repeatably to ASTM and ISO requirements for all gauge lengths. Reengineered quick attach wire forms provide simple and secure specimen attachment. Wire forms for round and flat specimens are included, as well as flat, 3-point, and vee knife edges. The wire forms may be removed to enable mounting using elastic bands or springs. A tethering attachment point provides fall protection and enables counterbalancing of the extensometer’s weight when testing delicate specimens.Model 3442 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller and Epsilon will equip the extensometer with a compatible connector wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of solutions for signal conditioning and connection to data acquisition systems, chart recorders, or other equipment.

Get Help