Filter Results By:

Products

Applications

Manufacturers

Systems

are interconnected groups of purpose.

See Also: Equipment, Test Systems, System Integrators, System Test


Showing results: 961 - 975 of 17123 items found.

  • Data Logging System

    SPARTAN - imc Test & Measurement GmbH

    SPARTAN is an affordable, compact multi-channel measuring system specially designed to optimize potential-isolated measurement of voltage and temperature. With a sampling rate of up to 10 kHz per channel, even highly dymanic processes can be recorded with high resolution.

  • Thuraya Interception System

    Shoghi Communications Ltd.

    The Strategic Thuraya Monitoring System is designed to monitor Thuraya Satellite Phones operating on Thuraya-2 or Thuraya-3 Satellites network. The System is capable of providing both sides of the communication (full duplex call), call related information (CRI) along with the location of the Thuraya Phone by monitoring of both L & C-band. The Monitoring of L-band (between Thuraya satellite and Thuraya mobile) and C-band (between Thuraya Satellite and Thuraya Gateway), provides total traffic monitoring of the targeted spot beams each of which are nearly 350 - 400 Km. Normally 7 spot beams are available at any location under the Thuraya footprint.

  • Resonant Chopper Systems

    Electro-Optical Products Corp.

    An external clock signal, to provide an ultra stable modulating optical beam motion [sub] system. The system can be used as a "stand alone" unit, in the laboratory, or can be incorporated into a larger instrument/system. The chopper is ONE FIXED FREQUENCY, picked from the range of 5 Hz to 20 kHz. The chopper is a small size, light weigh, low cost and long life device. It requires low power drive electronics and does not radiate electromagnetic interference (EMI). It has high frequency stability and high amplitude stability. The chopper is IR, VIS and UV and high vacuum capable. Reference signal and position output available.

  • Current-Voltage Measurement System

    Sciencetech, Inc.

    Sciencetech''s IV Testers are electrical current-voltage measurement systems used to characterize photovoltaic cell performance. This current-voltage tester works by sampling various current versus voltage combinations of the photovoltaic cell with a variable impedence load.This IV Test system can measure electrical power from photovoltaic cells up to 20W. The voltage envelope is limited to 20V and the current to 1A. A higher power version, up to 60W, is available. In general, the limitation on this model is the 1A current limit: if your solar cell generates more than 1A, we recommend upgrading to the 60W version.

  • Vibrator Control System

    FORCE-III - Seismic Source Co.

    The Force 3 Vibrator Control System is the newest generation of vibrator control system. It is designed to control individual vibes, or synchronize entire fleets of trucks. Using GPS, or VHF/UHF radio, for its time base the Force 3 both starts the Vibrator and controls its sweep with unparalleled precision and accuracy.The Force 3 is equipped with the latest ADC chips for better sweep resolution, increased computing power for faster response, GPS for precise source location, 8 Gbytes of internal memory for integrated VSS and PSS data storage, and integrated Wi-Fi for easy data offloading.

  • High Voltage System

    HV-2 - International Electro-Magnetics, Inc.

    *Tests Power Transformers for Continuity, Ratio and Phase. Applied and Induced Potential and No-load Losses.*14 Conductor Switching Matrix will test 7 individual windings, 13 taps of one common winding or some combination thereof. (10 Amp current limit)*The System Control is Windows/Visual Basic based. Menu screens allow full selection of test parameters and sequence. Low voltage tests can be performed first, allowing defective parts to be rejected without proceeding to time consuming induced Potential dwell routines. Test data labeling and data acquisition software can be easily added to the system.

  • ICP Plasma System

    Axic Inc.

    The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.

  • Generator Loading System

    Mosebach Manufacturing Company

    GLS (Generator Loading System) is a load bank for use with your generator to load it automatically to your set point. This will keep your generator running at its optimal point and reduce your maintenance costs. Fully programmable by you.

  • Ground Grid Systems

    ETAP Enterprise

    The Ground Grid systems module enables engineers to quickly and accurately design and analyze ground protection. Flexible design methodologies allow for quick auto-designed layouts or very detailed schemes. Color-coded graphical plots provide impressive results.

  • Measurement Microphone System

    7052SYS - ACO Pacific, Inc.

    The 7052SYS Type 1.5TM measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 4 Hz to >20 kHz response, 20 mV/Pa sensitivity and a "A" weighted noise floor less than 20 dBA.

  • Measurement Microphone System

    MK224SYS - ACO Pacific, Inc.

    The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.

  • Portable Security System

    Sensor-1 - Metasensor Inc.

    The portable security system that fits in the palm of your hand. Sensor-1 detects real-time changes in motion and alerts you when your important items move. Operates independent of the mobile app. Communicates with smartphones, tablets, laptops and desktops.

  • Brake Test Systems

    GIANT 9000 Series - HORIBA, Ltd.

    The major test target is to detect noise and vibrations generated by the vehicles brake. Our intention was to build a dynamometer that can operate either with brakes mounted to the complete vehicle, or with just the axle module mounted to a universal adaptor system or wheel suspensions.

  • Specimen Radiography System

    XPERT 40 - Kubtec

    Whether in the biopsy suite or the pathology lab, nothing beats the XPERT 40 Specimen Radiography System in terms of versatility and speed. A 50kV, 1.0 mA X-ray penetrates the densest cores and surgical specimens, identifying the finest details in seconds.

  • S-Parameter Measurement System

    DPS08 - KEYCOM Corp

    KEYCOM provides S-parameter method measurement systems in two modes, the reflection mode and the transmission mode, to address the individual purposes. Both modes measure the complex permittivity (εr) and complex permeability (μr) at the same time, and the proper usage is as follows.

Get Help