Filter Results By:

Products

Applications

Manufacturers

Tan Delta

test's dielectric loss to determine quality of insulator.

See Also: Tan Delta Bridges, Dissipation Factor, Dielectric Test, Oil


Showing results: 31 - 45 of 45 items found.

  • Compensating Reactor

    RCTD - Altanova Group

    This module is properly designed for testing Tan Delta in rotating machines with TD 5000 and allows increasing the test current and getting the maximum test voltage with high capacitive burdens

  • Transformer Oil Tester

    GTD-61A - Kingrun Instrument Co., Ltd.

    1. The GTD-61A Automatic Oil Tan Delta(OTD) & Oil dielectric loss tester is highly automated, allowing for the measurement of temperature rise, dielectric loss, and resistance in one go.

  • C-DF Res Calibrator

    Eltel Industries

    This calibration box is used to routinely check and inspect test sets. The portable calibrator offers one Capacitance, three Tan Delta and four Resistivity values. The maximum operating voltage is 500V AC/DC.

  • Calibrator Module

    CAP CAL - Altanova Group

    The purpose of CAP-CAL is to check the correctness of Tan Delta and Capacitance of TD 5000 and TDX 5000. The calibrator includes an extremely high accuracy high voltage capacitor, which comes with a certificate issued by ISA - Altanova Group lab.

  • Capacitance & Tan-Delta Test System

    TD-1 - AJIT Electronics Co.

    By measuring the electrical properties such as capacitance and Tan-Delta regularly on periodical basis, it is possible to ensure the operational unexpected breakdown. Dissipation factor (Tan Delta) is one of the most powerful off-line nondestructive diagnostic tool to monitor the condition of solid insulation of various high voltage equipment.

  • VLF/DC Hipots

    HVA28TD - HV Diagnostics Inc.

    The smallest VLF /DC unit on the market now includes an integrated Tan Delta measurement system to perform advanced electrical insulation diagnostics. For example, this can be extremely useful when performing advanced diagnostics on cable systems as it provides valuable information as to the condition of the cable insulation and shield.

  • Conventional Power Supply Design with Simple Analog Controls

    VLF Series - High Voltage Inc.

    VLF hipots perform voltage withstand tests and provide the voltage source for diagnostic cable testing. There is no better method for verifying the AC integrity of a cable than applying VLF AC voltage. Tan delta and partial discharge measurement accessories are frequently purchased along with VLF equipment to extend their capabilities.

  • Fully Programmable Digital Design with Wireless Remote Control

    VLF E Series - High Voltage Inc.

    The VLF E Series uses a state-of-the-art, switching power supply design with wireless computer controls. Equipped with HVI’s E-Link software, the E Series stands among the most advanced cable testing systems available. Our customers praise its flexible data capture and reporting capabilities, full remote operation via XBee wireless technology, and seamless tan delta testing with HVI’s TD units.

  • Transformer Testing Instrument

    The Motwane Manufacturing Company

    Transformers are a vital link in the electrical distribution system. Accurate and timely transformer maintenance can prevent breakdowns by detecting potential causes, and eliminating them before danger strikes. In addition, regular maintenance ensures multiple years of trouble-free operation. Motwane offers a wide range of transformer maintenance products, such as the transformer turn ratio tester, winding resistance tester, automatic oil BDV tester, and oil tan delta resistivity tester.

  • Compensating Reactor

    Eltel Industries

    The compensating reactors are accessories for the CTS-12KSA/ACTS-12K Capacitance & Tan Delta Test Set. The use of one or more compensating reactors increases the capacitance that the internal power supply can excite to conduct measurements. As the measuring range of the CTS-12KSA / ACTS 12K exceeds the kVA rating of the internal power supply, one way of using the test set over its entire measuring range is to form a resonant circuit with the test sample. The use of one or more compensating reactors forms partial resonating circuit with the test specimen, thereby reducing the power supply requirement.

  • Test Sets For Diagnostic Testing

    NEO TELE-TRONIX PVT. LTD

    Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.

  • VLF Testing and Diagnostics Unit

    Viola TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences

  • VLF Testing and Diagnostics Unit

    Frida TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight

  • VLF Diagnostics System

    PHG 80 TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)

  • VLF Diagnostics System

    PHG 70 TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)