S25 TO-5 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile that offers the smallest single element active area size at 0.25mm x 0.25mm in a TO-5 package. Delivers a fast 18ms time constant in Argon encapsulation gas and even faster with Neon gas at 9ms. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C.
-
M5 -
Dexter Research Center, Inc.
A thin film-based thermopile offering very low noise and a small 0.5mm diameter active area in a TO-5 package. This is one of the lowest noise thermopiles you can buy and provides a time constant 28ms time constant with Argon encapsulation gas.
-
DR34 Compensated -
Dexter Research Center, Inc.
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.
-
ST150 With Diffractive Lens -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that delivers a very low Temperature Coefficient of Responsivity of -0.04%/C with a high output voltage, 19.5 FOV and a quick time constant of 38ms. This Low-cost detector comes in a TO-5 package and has a very short thermal shock response to ambient temperature change.
-
M34 -
Dexter Research Center, Inc.
A thin-film thermopile in a TO-5 package with an active area of 3.16mm x 0.4mm that offers low noise output.
-
1SC Compensated -
Dexter Research Center, Inc.
A thin film-based single channel thermopile detector that offers thermal compensation to minimize effects of sudden ambient temperature change during the initial five seconds of change. The 1SC Compensated comes in a TO-5 package with a medium sized 1.0 x 1.0mm active area. Compensation is achieved through the integration of two additional half-sized thermopile elements. Internal aperture is standard and precisely defines active area for applications with FOV and/or spot size requirements.
-
1M -
Dexter Research Center, Inc.
A thin film-based thermopile with a 1.0mm diameter active area with good signal-to-noise ratio in a TO-5 package and a moderate time constant of 32ms with Argon encapsulation gas.
-
ST60 TO-5 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
ST60 LCC -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile in a LCC package for surface mount assembly in a small active area of 0.61mm x 0.61mm. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature chang
-
ST60 With Diffractive Lens -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas and a 9 FOV. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
ST60 High Temperature -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile that will withstand operating temperatures of 225C, with a small active area of 0.61mm x 0.61mm in a TO-5 package. The reduced height package functions as an internal aperture. Two thermistor options provide ambient package temperature measurement. Currently only available with 8-14um silicon window. Time constant of 18ms with Nitrogen encapsulation gas delivers a very low Temperature Coefficient of Responsivity of -0.4%C. This detector has a very short thermal shock response to ambient temperature change.
-
Campbell Scientific, Inc.
Soil volumetric water content probes (sometimes referred to as soil moisture sensors) measure the water content of soil. These probes can be used to estimate the amount of stored water in a profile or how much irrigation is required to reach a desired amount of water in the soil. These probes can be used for quick measurements or installed for long-term measurements.
-
Labfacility Ltd.
Ergonomic Handle Style Sensors. A family of rugged, hygienic, IP67 rated, hand held temperature sensors for food, medical, light industrial and general purpose applications. The 'shark tail style' handle contains an antimicrobial substance which kills microorganisms, making it ideal for the food industry or applications where cleanliness is paramount.
-
FLIR A310 -
Teledyne FLIR
The FLIR A310 is a fixed-mounted thermal imaging camera that can be installed almost anywhere to monitor your critical equipment and other valuable assets. The camera can safeguard your plant and measure temperature differences to assess the criticality of a given situation. This allows you to see problems before they become costly failures, preventing downtime and enhancing worker safety.
-
Contrinex AG
Contrinex High Temperature Up To 230°C (446 °F) Inductive Sensors