Showing results: 151 - 165 of 190 items found.
-
HD49… Series -
Delta OHM S.r.L.
HD49 transmitters are designed for temperature and humidity control in conditioning and ventilation applications (HVAC/BEMS) in the following sectors: pharmacy, museums, clean rooms, ventilation ducts, industrial and civil sectors, crowded places, canteens, auditoria, gyms, high-density farms, greenhouses, etc.
-
HD9408.3B… Series -
Delta OHM S.r.L.
HD9408.3B is a barometric transmitter that uses a piezoresistive high accuracy and temperature-compensated sensor. It allows to measure the atmospheric pressure in the range from 500…1200 hPa, providing extreme accuracy and time stability, with excellent repeatability, low hysteresis, and excellent temperature behavior.
-
HD48… Series -
Delta OHM S.r.L.
HD48 transmitters are designed for temperature and humidity control in conditioning and ventilation applications (HVAC/BEMS) in the following sectors: pharmacy, museums, clean rooms, ventilation ducts, industrial and civil sectors, crowded places, canteens, auditoria, gyms, high-density farms, greenhouses, etc.
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation Amplifier for DC voltage and current measurement with galvanic isolation, active and passive standard signal isolation amplifier, supply isolation amplifier for supplying 2-wire sensors, transmitter for temperature and AC signals, isolating amplifiers for high voltages and shunt applications. T
-
NOSHOK, INC.
NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. The NOSHOK Attachable Loop Powered Digital Indicator can easily be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. NOSHOK also offers a dual display model that accepts a wide variety of input signals including thermocouples or RTDs, current, voltage, resistance and process signals. Plug-in option cards are available on several models for field upgrading.
-
LD-LOPC-A10 -
Labodam
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
AMETEK Sensors, Test & Calibration
Temperature measurement and calibration is our specialty, allowing us to provide much more than just standard sensors and assemblies. Our long experience, developing and producing industrial temperature sensors, provides us with a wide knowledge about applications and customer needs. This enables us to build and deliver quick and custom-designed quality temperature sensors for almost any kind of solutions and applications, no matter what industry. We offer a complete range of thermocouple assemblies and resistance thermometers, as well as thermocouple wire, extension wire, temperature transmitters and accessories.
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Universal Transmitter for temperature, load cells / strain gauge, potentiometer and resistance in 6 mm housing. Functional safety up to SIL 2, SIL 3 redundant to parameterization via interface or intuitively, directly on the device. Universal use with 24 V DC or AC power supply.
-
McLAREN Applied Technologies
The system consists of a powered pressure and temperature sensor with transmitter fitted to a wheel rim. This sends pressure and temperature data over an RF link to a compact receiver on the car. Sampling rates increase automatically when either a change in pressure is detected or when wheel inertia is detected. The system stops transmitting below a threshold pressure to preserve battery life. The receiver sends data to the car control via CAN.
-
LD-LOCC-A10 -
Labodam
Online Conductivity ControllerLD-LOCC-A10features 3 points conductivity calibration system, TDS measurement mode, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, Temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. This controller measures Conductivity and TDS values in µS/ cm, and mS/ cm units.
-
Cole-Parmer Instrument
Effective process control enhances the efficiency and performance of your operation. The heart of any sophisticated process is a controller that takes input from sensors and transmitters, measures process variables, and responds with output instructions to system components via relays and switches. We offer a wide range of process equipment including process controllers, temperature controllers, sensors and transmitters, signal conditioners, panel meters, and HMI devices. Plus we provide expert technical assistance to help you find the best solution for your application.
-
Universal II -
AMETEK Drexelbrook
The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.
-
MS 1522 -
Meltronics Systemtech
Transmitter and Receiver units are designed to work at 24V DC voltage (nominal) with variation between 19.2 V to 28.8V. The system is designed to work with carrier frequency 1800/2700 Hz and modulated frequency 65Hz/85Hz. For 1800Hz Carrier Frequency RED border is used in Front Panel and for 2700Hz Carrier Frequency BLUE border is used in Front Panel. Maximum power consumed by transmitter and receiver are 1.2W and 8W, respectively. Sense level for receiver is less than –19 dBm and No sense level for receiver is more than –22 dBm with 1mw (0 dBm) transmitter power. The equipment is designed to work satisfactorily with temperature variation from 0°C to 55°C with relative humidity of 95% at 35°C. Suitable test points are provided in the back of the equipment to monitor the necessary parameters.
-
DR800 -
Validyne Engineering
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
WIKA Alexander Wiegand SE & Co. KG
Resistance thermometers are equipped with platinum sensor elements which change their electrical resistance as a function of temperature. In our range of products you will find versions with connected cables as well as versions with connection heads. A temperature transmitter can be installed directly in the connection head. Furthermore, in the WIKA product portfolio, in addition to threaded resistance thermometers, flanged resistance thermometers or process resistance thermometers, you will also find the right measuring insert for your application.