Showing results: 1786 - 1800 of 5166 items found.
-
PCE Instruments
The pyrometer is ideal for taking accurate measurements of temperature without contact. Thanks to an optical mechanism, the pyrometer is safe for measuring high temperatures. Its infrared capabilities make the pyrometer the perfect tool to use when a conventional sensor is inadequate. A pyrometer is useful for measuring moving, extremely hot or hard-to-reach objects. Many pyrometer models can be calibrated to meet ISO standards.
-
MX-9200 -
LR Environmental Equipment Co. Inc.
A high reliability thermostatic temperature controller maintains the salt solution at a preset controlled temperature in a reservoir within the double wall construction. The salt solution is introduced into the chamber through an atomizing nozzle. The nozzle can be calibrated by us to perform to MIL-STD-19500B, paragraph 40.8 and other specifications. This specification requires that a salt residue be deposited on the specimens, in addition to generating salt fog atmosphere.
-
TH-5/AOP -
Physitemp Instruments
The TH-5?AOP is one of our most economical precision thermometers in the Physitemp product line. The TH-5/AOP offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-5 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
TS-4SMP -
Physitemp Instruments
With our TS-4SMP Thermal Stage for Petri Dish, a specimen on a microscope slide or culture dish can be maintained at any temperature between -20°C and +60°C. Setup is easy, takes little time, and the controller will regulate the stage temperature to within +/-0.1°C. The collar on the stage is designed to accommodate a 35mm 'Nunc' petri dish. The collar may also be removed for use with slides.
-
T7511-4 -
COMET SYSTEM, s.r.o.
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
T7511 -
COMET SYSTEM, s.r.o.
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
T7510 -
COMET SYSTEM, s.r.o.
Web Sensor with built-in temperature, relative humidity and atmospheric pressure sensors. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
T7511-2 -
COMET SYSTEM, s.r.o.
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
IR-300 Series -
HORIBA, Ltd.
Metal-Organic Chemical Vapor Deposition (MOCVD) is widely used in the manufacture of LEDs, optical devices and other components. Liquid and solid precursors are delivered to the reaction chamber by controlling the temperature, pressure and the carrier gas flow rate (bubbling method). Process results can be affected by changes especially in temperature and liquid level. The in-line IR-300 Series measures and reports the precursor concentration in real time.
-
EverythingPCB
AkroMetrix provides a variety of products to help you identify and evaluate warpage: For warpage measurements along a production line or at room temperature, AkroMetrix has developed the LineMoiré Production Level Automated Flatness Inspection System. If you need to measure warpage and flatness during pre-defined temperature profiles, AkroMetrix's TherMoiré In-Process Warpage Measurement Systems may fit your requirements.
-
CIP-1000 -
Advanced Thermal Solutions, Inc.
The CIP-1000, Controllable Isothermal Plate, is a system for providing an isothermal surface that can be precisely temperature-controlled from 10 to 170C with an accuracy of +/- 0.1C. The CIP-1000 features a 75 mm diameter isothermal copper plate whose constant temperature can be raised or lowered both automatically and manually. A three wire RTD sensor and integral PID controller ensure specific, uniform temperature across the entire plate.
-
866 -
TEGAM Inc.
Tegam's Model 865 & 866 digital, thermistor thermometers measure temperatures from -70°F to 300°F, (-55°C to 150°C). Compatible with all YSI Series 400 probes, temperature measurement is performed with a basic accuracy of .3%. These thermometers are specially constructed with a heavy duty ABS case specifically designed for durability and resistance to contaminants such as dust and most chemicals.
-
868 -
TEGAM Inc.
Models 868 and 869 digital RTD thermometers measure temperatures from -360F to 1100F, (-220C to 630C). Compatible with either 3 or 4 wire RTDs, temperature measurement is performed with a best accuracy of .4F(.3C). These thermometers are specially constructed with a heavy duty ABS case specifically designed for industrial use. Model 868 reads in F and Model 869 reads in C.
-
R15-LPCIE -
Abaco Systems Inc
Abaco Systems Embedded Systems’ R15-LPCIE is the latest generation of performance and flexibility for MIL-STD-1553A/B Notice II on a low profile PCI Express module. Available in -40 to +70 temperatures (with relays) and -40 to +85 temperatures (without relays) with one or two dual-redundant channels. The R15-LPCIE includes advanced API (Application Programming Interface) software that reduces application development time.
-
P37AB147 -
Delta OHM S.r.L.
Temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide) combined probe, complete with SICRAM module.