H7531-2 -
COMET SYSTEM, s.r.o.
Sensor H7531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
Rotronic Measurement Solutions
The main fields of use for humidity measuring equipment lie in the pharmaceutical and food industries, heating, ventilation and air-conditioning (HVAC) applications as well as drying processes and storage. Measurement of air humidity moreover plays a key role in meteorology, while archives and museums also use data loggers or humidity measuring instruments. Apart from humidity, temperature is often also measured. Rotronic humidity measuring instruments therefore usually also measure temperature at the same time.
-
Model T102 -
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
Elcometer Limited
To maintain consistency of a coating, the Density should remain constant from batch to batch. Density Cups, also known as Specific Gravity Cups or Picnometers, are used to determine the mass per unit volume (Specific Gravity) of a liquid at a given temperature. Specific Gravity is defined as the ratio of the density of a given substance to the density of water, when both are at the same temperature. As the Specific Gravity Cup is an exact measurement of the volume of the liquid, it is imperative that the exact weight of the sample is obtained.
-
Wewon Environmental Chambers Co, Ltd.
The environmental chamber for conditioning of samples prior to testing, It also can be used for a variety of materials of high – low temperature alternating test. The test for temperature, humidity, time can be programmed. Provides conditions of temperature from -70 degree to +180 degree and of humidity form 10% to 98%.environmental chamber ● The ideal simulation environmental chamber for all heat and cold testing between -70 ºC and 180 ºC temperature range.● Well suited for reliability testing based on current test standard in the temperature range of -70 °C to 180 °C & 10% to 98% RH.● This design SUS environmental chamber meet all requirements for extreme testing and low temperature alternating climate profiles from -70 °C -180 °C with humidity
-
Fieldpiece Instruments, Inc
The Fieldpiece Non-contact Infrared Temperature Accessory with Laser Sight, model ATIR3, collects infrared energy (IR) and converts it to a mVDC signal that is proportional to the temperature being measured. The temperature measured is the average of all the temperatures in the 8:1 cone of viewability. The closer you are to the target, the smaller the area measured. The further away, the larger the area. The digital, non-contact ATIR3 converts the Fieldpiece “Stick” series meter, or electronic handle to a one-piece infrared, or IR, thermometer.
-
MicroClimate 3 -
Cincinnati Sub-Zero Products
The MicroClimate 3 is a compact environmental chamber designed to simulate a full range of temperature and/or humidity conditions. The small footprint of the MicroClimate 3 combined with temperature and humidity capabilities make this chamber the number one choice for testing small components and products. Whether you need to perform temperature cycling tests or expose your product to steady state temperature environments, these chambers will maintain precise and accurate temperature/humidity control throughout your test.
-
Extech SDL310 -
Extech Instruments Corporation
The SDL310 records data on an SD card in Excel format. Measures Air Temperature to 122°F (50°C) and air velocity to 4930ft/min. Stores 99 readings manually and 20M readings via 2G SD card. Stores 99 readings manually and 20M readings via 2G SD card. Type K/J Thermocouple input for high temperature measurements. Large (9999 count) LCD displays Air Velocity and Temperature simultaneously. 2% velocity accuracy via low friction ball bearing vane wheel on 39 in. (1m) cable. Record/Recall Min, Max, Data Hold and Auto power off. Adjustable data sampling rate. Complete with 6 x AA batteries, SD card, vane sensor with 3.9ft (120cm) cable, and hard carrying case.
-
ATAL
Beautifully designed CO2 meter / indicatorEquipped with 3 color traffic light indicatorEquipped with integrated temperature and humidity sensorVery favorable pricing, including AC adapter and table stand
-
RCP-200 -
Malcom Co.,Ltd.
Unprecedented miniature size, high precision, stable, and well-reproducible temperature control of reflow furnace. Proprietary "Heat Resistant Micro Connector" makes it possible to measure at 6 points.
-
HD2106.2 -
Delta OHM S.r.L.
Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature. Datalogger which can store the maximum, minimum, average value and can store up to 36,000 samples.
-
Ametek Land
The Land Cyclops Logger Software allows you to connect a Land Cyclops Portable pyrometer to a personal computer or mobile device and view, analyse and record live temperature readings.
-
MS6R -
COMET SYSTEM, s.r.o.
The complete solution for monitoring of temperature, humidity and other values. For desktop use with rubber feet - see Optional accessories. For mounting to 19" rack - one rack unit 1U.
-
HEM Data Corp
The DAWN Mini ADAQ™ measures a variety of input types including voltage, current, temperature, digital, frequency, PWM, and inclination. It outputs measured data to a CAN network.
-
CPC Chassis Mount Series -
Semiconductor Circuits, Inc.
High performance DC-DC converters offer high efficiencies of 93% typical (12V model.) This high efficiency allows for minimal output current derating at elevated ambient temperatures.