Showing results: 2281 - 2295 of 5166 items found.
-
DCBM 400 / 600 -
LEM
*Split concept for easy integration*Range of operation 150 to 1000 V DC*Two sizes: Imax 400 A and Imax 600 A*Bi-directional energy metering*Wide operating temperature range
-
MS 1000-PBL-20 -
Advanced Thermal Solutions, Inc.
The MS 1000-PBL-20 is a three-sensor probe designed for the measurement of air velocity and temperature in the same vertical plane. It eliminates the need for multiple probes or a traversing probe for determining the flow profile or distribution.
-
MS 1000-IP-20 -
Advanced Thermal Solutions, Inc.
The MS 1000-IP-20 is a three-sensor probe designed for measuring fluid velocity and temperature in the same vertical plane. It eliminates the need for multiple probes or a traversing probe for determining the flow profile or distribution.
-
SUN-FSW-1x2 -
Guilin GLsun Science and Tech Group Co., LTD
GLSUN 1x1 Mechanical Optical Switch - Features·Low Insertion Loss·Wide Wavelength Range·Low Crosstalk·Epoxy-free on Optical Path·High Stability, High Reliability·Latching and Non-latchingGLSUN 1x1 Mechanical Optical Switch - Applications·R&D in Laboratory·System Monitoring·MAN (Metropolitan Area Network)·Network Security and Monitoring·OADMGLSUN 1×1 Optical Switch - SpecificationsParameters Unit SUN-FSW-1×1Wavelength Range nm 850±40 / 1300±40 1260 ~ 1650Test Wavelength nm 850 / 1300 1310 / 1550Insertion Loss 1,2 dB Typ: 0.5 Max: 0.8 Typ: 0.4 Max: 0.6Return Loss 1, 2 dB MM ≥ 30 SM ≥ 50Crosstalk 1 dB MM ≥ 65 SM ≥ 70PDL dB ≤0.05WDL dB ≤0.25Repeatability dB ≤±0.02Operating Voltage V 3.0 or 5.0Durability Cycles ≥ 10 MillionSwitching Time ms ≤8Optical Power mW ≤500Operating Temperature ℃ -20 ~ +70Storage Temperature ℃ -40 ~ +85Relative Humidity % 5 ~ 95Weight g 14Dimension mm (L)27.0×(W)12.6×(H)8.2 ±0.2Note: 1 Within operating temperature and SOP.2 Excluding Connectors.
-
SUN-FSW-1x1 -
Guilin GLsun Science and Tech Group Co., LTD
GLSUN 1×1 fiber optic switch -Features·Low Insertion Loss·High Stability, High Reliability·Low Crosstalk·Wide Wavelength Range·Epoxy-free on Optical Path·Latching and Non-latchingGLSUN 1×1 fiber optic switch -Applications·System Monitoring·OADM·R&D in Laboratory·MAN (Metropolitan Area Network)·Network Security and MonitoringGLSUN 1×1 fiber optic switch - SpecificationsParameters Unit SUN-FSW-1×1Wavelength Range nm 850±40 / 1300±40 1260 ~ 1650Test Wavelength nm 850 / 1300 1310 / 1550Insertion Loss 1,2 dB Typ: 0.5 Max: 0.8 Typ: 0.4 Max: 0.6Return Loss 1, 2 dB MM ≥ 30 SM ≥ 50Crosstalk 1 dB MM ≥ 65 SM ≥ 70PDL dB ≤0.05WDL dB ≤0.25Repeatability dB ≤±0.02Operating Voltage V 3.0 or 5.0Durability Cycles ≥ 10 MillionSwitching Time ms ≤8Optical Power mW ≤500Operating Temperature ℃ -20 ~ +70Storage Temperature ℃ -40 ~ +85Relative Humidity % 5 ~ 95Weight g 14Dimension mm (L)27.0×(W)12.6×(H)8.2 ±0.2Note: 1 Within operating temperature and SOP.2 Excluding Connectors.
-
SUN-FSW-1x2H -
Guilin GLsun Science and Tech Group Co., LTD
GLSUN 1×2H Mechanical Optical Switch Fiber Switch Features·Low Insertion Loss·Wide Wavelength Range·Low Crosstalk·High Stability, High Reliability·Epoxy-free on Optical Path·Latching and Non-latchingGLSUN 1×2H Mechanical Optical Switch Fiber Switch Applications·R&D in Laboratory·System Monitoring·OADM·MAN (Metropolitan Area Network)·Network Security and MonitoringGLSUN 1×2H Mechanical Optical Switch Fiber Switch SpecificationsParameters Unit SUN-FSW-1×2HWavelength Range nm 1260 ~ 1650Test Wavelength nm 1310 / 1550Insertion Loss 1, 2 dB Typ: 0.8 Max: 1.0Return Loss 1, 2 dB SM ≥ 50Crosstalk 1 dB SM ≥ 55PDL dB ≤0.05WDL dB ≤0.25Repeatability dB ≤±0.02Operating Voltage V 3.0 or 5.0Durability Cycles ≥ 10 MillionSwitching Time ms ≤8Optical Power mW ≤500Operating Temperature ℃ -20 ~ +70Storage Temperature ℃ -40 ~ +85Relative Humidity % 5 ~ 95Weight g 14Dimension mm (L )22.5×(W)11.8×(H)10.2 ±0.2Note: 1 Within operating temperature and SOP.2 Excluding Connectors.
-
OAKTON Instruments
The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.
-
Extech SDL300 -
Extech Instruments Corporation
The SDL300 records data on an SD card in Excel format. Metal Vane withstands temperatures to 158°F (70°C) and air velocity to 6900ft/min. Datalogger date/time stamps and stores readings on an SD card in Excel format for easy transfer to a PC. Adjustable data sampling rate from 1 to 3600 seconds. Stores 99 readings manually and 20M readings via 2G SD card. Type K/J Thermocouple input for high temperature measurements. Large (9999 count) LCD displays Air Velocity and Temperature simultaneously. 2% velocity accuracy via low friction ball bearing vane wheel on 39" (1m) cable. Record/Recall MIN, MAX, Data Hold, Auto Power Off. Complete with 6 x AA batteries, SD card, metal vane sensor with 3.9ft (120cm) cable, and hard carrying case.
-
Sanwood Environmental Chambers Co ., Ltd.
Energy-saving design: Adopting PID + PWM principle of VRF (refrigerant flow control) technology to achieve low-temperature energy-saving operation (electronic expansion valve according to thermal energy conditions refrigerant flow servo control technology) low temperature working state, the heater does not participate in the work, through PID + The PWM regulates the flow rate and flow direction of the refrigerant, and regulates the three-way flow of the refrigerant pipe, the cold bypass pipe, and the hot bypass pipe to achieve automatic constant temperature to the working chamber. This method can reduce energy consumption by 30% under low temperature conditions. The technology is based on Danish Danfoss' ETS series of electronic expansion valves, which can be used to smoothly adjust the cooling capacity for different cooling capacity requirements, that is, to achieve the compressor cooling capacity adjustment when different cooling rate requirements are met.
-
Hua/Hud Series -
Semiconductor Circuits, Inc.
The HUA/ HUD is a cost-effective series of DC/DC converters, offering both single and dualoutputs. These unregulated converters offer the latest in MOSFET technology. Featuring efficiencies to 80%, cool operating case temperatures and a high level of reliability with a MTBF in excess of 1,000,000 hours. Additional standard features include an internal Pifilter, 500 Vdc I/O isolation, up to 12 watts of output power and operating temperature of –25°C to +71°C with no derating. All this in a package measuring 2.0” x 2.0” x 0.40” high.
-
Huaxin instrument (Beijing) Co., Ltd
Reputed as a specialized pressure measurement solution provider, Huaxin offers an excellent selection of digital pressure gauges. Unique industrial design and state of the art technology have made our digital pressure gauges an ideal pressure calibration instrument for various applications. Depending on high and low temperature aging and temperature compensation processes before delivery, they feature guaranteed accuracy and stability. The digital gauges have been extensively used in power, metallurgy, chemical, measuring and military industries for calibrating precision pressure measurement devices.
-
ENVIROMUX-GSM-IND -
Network Technologies Inc
Sends SMS messages to a pager or cell phone when a sensor goes out of range of a configurable threshold. SIM card supporting SMS messaging required (not included). Ideal for harsh environments and high temperatures up to 149°F (65°C). GSM/GPRS/EDGE 850/900/1800/1900 MHz. AT command compatible. Dimensions: 3.58x2.28x0.87 in (91x58x22 mm). Operating temperature: -13 to 149°F (-25 to 65°C). Operating humidity: up to 95% non-condensing RH. Regulatory approvals: CE, C-Tick. Compatible with ENVIROMUX-SEMS-16(U).
-
ThermoWorks
Easily measure surface temperatures with ThermoWorks non-contact IR guns, ideal for produce and agriculture inspectors, HVAC, construction, warehouse, quality assurance, HACCP and cold chain management, both shipping and receiving. Choose from fixed or adjustable emissivity; single, dual or circle laser types; and lens optics from close focus—for electronic components and laboratory measurements—to 100:1—for long distance measurements. High temperature ranges up to 3272°F (1800°C) are perfect for metallurgy and metal work foundries.
-
MT-4 -
Physitemp Instruments
Fast-response 29 gauge needle probe with blunt tip, (needle length is 1cm) for instant readings. Good for instant skin temperature and surface temperatures, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
RFM700-M -
Xylem Analytics UK ltd.
RFM700-M series refractometers are robust, low cost, fully automatic instruments that are ideally suited to the food, sugar and beverage industries but can now be used in many other non food applications where use of temperature control is not required. RFM700-M Series refractometers are robust, low cost, fully automatic instruments that are ideally suited to the food, sugar and beverage industries but can also be used in many other non-food applications where temperature control is not required, for example measuring sugar (Brix) concentrations in the food processing industry.