Showing results: 916 - 930 of 5166 items found.
-
845 -
TEGAM Inc.
Functionally the same as the Model 840A, the 845 adds several thermocouple types for greater flexibility in calibrating K-J-T-E-N-B-R-S-G-C and D-type thermocouple thermometers in the lab or out in the field. This device is a handy verification tool for QA inspectors and manufacturing engineers.
-
785854-01 -
NI
The FD-11614 measures up to 16 thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11614 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11614 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11614 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
85530B -
Keysight Technologies
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards.
-
Model KM 8022 -
Kusam Electrical Industries Limited
• Measures : m/s, km/h, fpm, mph, kts, Beaufort, °C, °F, m³ /s; m³ /h; CFM; m²; ft²• Resolution : 0.1m/s 1fpm , 0.1°C, 0.1°F, 1m³ /s• Range : 0.4 ~ 20m/s, 0 ~ 99999m³ /s; -10 ~ 50°C, 14 ~ 122°F• Accuracy : (2% or reading + 0.3m/s), ± (2% of reading + 60fps), ± 1°C, ± 1.8°F, ± (3% or reading ) m³/s• Special Function : Auto Power off ; Data Hold ; MAX MIN;• Back light ; Overload display ; Low battery indicator
-
Guangdong Bell Experiment Equipment Co.,Ltd
DGBELL Walk in Chamber for Rapid Rate Temperature / Humidity Test Relevant standards requirement:Temperature shockTest Object: Battery storage pack or system.Li-ion battery pack or system placed in (-40±2)℃~(85±2)℃ alternation temperature, the conversion time of two extreme temperatures is less than 30 minutes. Place the test objects into each extreme temperature keep 8h, test 5 cycles.Observe for 2 hours under the room temperature after testing,Humidity & Temperature CyclingTest Object: Battery storage pack or system.Refer the GB/T2423.4 Test Db, variable refer the Graph 4,the highest temperature is +80℃,5 cycles. Observe for 2h under the room temperature.
-
FLIR A320 Tempscreen -
Teledyne FLIR
The FLIR A320 Tempscreen camera is preconfigured for monitoring individuals to find temperature deviations or elevated skin temperature, including difference temperature alarms with a dynamically updated reference temperature. This temperature measurement solution offers built-in analysis, alarm functionality, and autonomous communication using standard protocols. The FLIR A320 Tempscreen also has features and functions to build distributed single- or multi-camera solutions utilizing standard Ethernet hardware and software protocols.
-
Extech 850186 -
Extech Instruments Corporation
The Extech 850186 is a Surface Temperature RTD Probe. It has a platinum RTD temperature sensor (100 Ohm) capable of measuring temperature from -40°C to 250°C (-40°F to 482°F).For use with the Extech model 407907. Comes with a 6 month warranty.
-
CX-DWC -
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60884-1 Uses: It is used to evaluate the impact resistance of electrical accessories under low temperature conditions, and also to evaluate the low temperature impact resistance of wire and cable.
-
ECOPIA
Super high temperature hall effect measurement system that is useful to flow gas into chamber with sample. - Newly developed furnace that makes it possible to increase over 800 and use for measuring hall effect. - Gas flow control system in order to flow various gas. - Sample holder for high temperature. (keep the good contact on 800) - High Temperature control system (DC power) On condition of specific temperature with gas flow , new semiconductor materials have been developed to see electrical property's change.
-
G-8 Elite -
Russells Technical Products
Russells G-8 Elite Series temperature and temperature / humidity chambers represent one of our pre-engineered environmental chambers. This model has a chamber volume in 8 cubic feet or 226 liters. Russells G-Series Elite portable test chambers give you the features and accessories you need to keep your temperature and humidity lab tests running smoothly.
-
TP-1 -
Shenzhen Chuangxin Instruments Co., Ltd.
TP series of multiplex temperature meter is a kind of instrument which suits to real time monitor and trace multi-points temperature simultaneously. With the features of Simplified operation, high precision and reusable thermocouple, it is widely applied in electronic ballast, motor tools, lighting fixtures and household appliances. The application software records and save the temperature rising curve in real time for analyze purpose.
-
MU thermocouple1 CAN FD -
PEAK-System Technik GmbH
With the MU-Thermocouple1 CAN FD, measurement data from thermocouples are recorded, pre-processed and transmitted with CAN FD. The temperature is measured via 8 connections, which are designed for the temperature measuring ranges J, K or T, depending on the product version. Temperatures can be recorded in Celsius, Fahrenheit or Kelvin and calculated with an individual factor and offset. The measurement data is then transmitted via CAN FD or via classic CAN.
-
SCR ELEKTRONIKS
The SCR Elektroniks 3 station MCB Temperature Rise and Power Loss Test Bench is economically designed to verify temperature rise and measure power loss as per clause 9.8 of IEC 60898 with the circuit designed to follow test procedure as per Cl 9.8.2. The temperature rise is measured in accordance with Cl 9.8.3 and 9.8.4 while power loss is measured and verified as per Table 15 of Cl 9.8.5.
-
-